In this paper, a sensor using modified Split Ring Resonators (SRRs) is designed, simulated, fabricated, and used for advanced investigation and precise measurements of the real part and imaginary part solid dielectrics’ permittivity. Adding vertical strips tightly coupled to the outer ring of the SRR leads to the appearance of two resonant frequencies at 1.24 GHz and 2.08 GHz. This modified geometry also assures an improved sensitivity. Using the full wave electromagnetic solver, both the unloaded and loaded sensors are investigated. The numerical simulations are used to develop a mathematical model based on a curve fitting tool for both resonant frequencies, allowing to obtain analytical relations for real and imaginary parts of permittivity as a function of the sample’s thickness and quality factor. The sensor is designed and fabricated on 1.6 mm thick FR-4 substrate. The measurements of different samples, such as transparent glass, acrylic glass, plexiglass, and Teflon, confirm that the modified SRR sensor is easy to implement and gives accurate results for all cases, with measurement errors smaller than 4.5%. In addition, the measurements highlight the importance of the second resonant frequency in the cases in which numerical limitations do not allow the usage of the first resonant frequency (1 mm thick sample).
A microstrip highly sensitive differential sensor for complex permittivity characterization of urine samples was designed, fabricated and tested. The sensing area contains two pairs of open-stub resonators, and the working frequency of the unloaded sensor is 1.25 GHz. The sensor is easily implemented on an affordable substrate FR-4 Epoxy with a thickness of 1.6 mm. A Teflon beaker is mounted on the sensor without affecting the measurements. Numerically, liquid mixtures of water and urine at different percentages were introduced to the proposed sensor to evaluate the frequency variation. The percentage of water content in the mixture varied from 0% (100% urine) to 100% (0% urine) with a step of 3.226%, thus giving 32 data groups of the simulated results. Experimentally, the mixtures of: 0% urine (100% water), 20% urine (80% water), 33% urine (66% water), 50% urine (50% water), 66% urine (33% water), and 100% urine (0% water) were considered for validation. The complex permittivity of the considered samples was evaluated using a nonlinear least square curve fitting in MATLAB in order to realize a sensing sensitivity of about 3%.
A compact 3-dB dual band ring coupler is designed, fabricated and tested. The coupler consists of three identical miniaturized Left-Handed (LH) impedance inverter transmission lines (TLs) and a dual one. The general principle of using LH TLs’ duality to reduce the size of a dual band ring coupler is explained in detail, showing the equivalent lumped element circuits and the designing relations. A numerical example is considered for the duality analysis and the results are used to obtain a size reduction for both the coupler’s dimensions and the number of utilized components. Other arbitrary coupling levels (1 dB and 5 dB) and frequency ratios are investigated and the results of simulations show very good results, proving the validity of the general principle of using LH transmission line’s duality. The 3-dB coupler is implemented in microstrip technology and using high-quality lumped components. It works at two arbitrary frequencies, 1.1 GHz and 2.5 GHz, respectively with similar performances. The overall dimension of the proposed coupler is $0.07\lambda \times 0.07\lambda $ for a wavelength, $\lambda $ computed at 1.1 GHz. The measured results are in good agreement with the predicted ones for both frequencies, having the return loss and isolation loss better than 33 dB, whereas keeping the insertion and coupling losses at around 3.5 dB in both frequency bands. The phase imbalance at the output ports is less than 1.5°, when the difference and sum ports are excited.
In this paper there are studied the electromagnetical phenomena which appear when coupling two Composite Right-Left Handed (CRLH) artificial transmission lines with different cells dimensions, one of them being two times smaller. There are analyzed the frequency ranges where the strong coupling appears and also, the differences between the simulated results and the measured ones are compared.
This study details the design, fabrication, and experimental validation of a wearable, non-invasive microwave sensor for continuous blood glucose monitoring. It incorporates a crescent-loaded elliptical patch antenna with a complementary split-ring resonator (CSRR) tag unit to greatly improve sensing sensitivity. The sensor operates across multiple resonant frequencies, enabling broadband dielectric characterization of glucose-dependent blood permittivity. Incorporation of the CSRR tag unit leads to a marked improvement in electromagnetic coupling and field confinement, resulting in a substantial increase in sensitivity, achieving 1.14 MHz/mg/dL in resonant frequency shift and 0.015 dB/mg/dL in reflection coefficient sensitivity compared to conventional designs. The sensor was fabricated on an FR-4 substrate and experimentally characterized using a vector network analyzer (VNA), showing strong agreement between simulated and measured S11 responses, with minimal frequency deviations and consistent resonance behavior. Experimental results confirmed improved sensitivity in response to glucose concentration variations over the range of 0–500 mg/dL, validating the sensor’s performance under realistic conditions. Furthermore, a physics-informed deep learning (PI-DL) model was developed to predict glucose concentration directly from measured S11 data. The model achieved enhanced prediction accuracy, with a mean absolute error below 1 mg/dL and a strong generalization across unseen samples, demonstrating the power of combining physical modeling with data-driven approaches. These results confirm that the proposed sensor, enhanced with the CSRR tag unit and supported by a PI-DL framework, offers a promising pathway toward next-generation non-invasive, accurate, and wearable glucose monitoring solutions.
In this study, a two-port network-based microwave sensor for liquid characterization is presented. The suggested sensor is built as a miniature microwave resonator using the third iteration of Hilbert’s fractal architecture. The suggested structure is used with the T-resonator to raise the sensor quality factor. The suggested sensor is printed on a FR4 substrate and has a footprint of . Analytically, a theoretical investigation is made to clarify how the suggested sensor might function. The suggested sensor is created and put to the test in an experiment. Later, two pans to contain the urine Sample Under Test (SUT) are printed on the sensor. Before loading the SUT, it is discovered that the suggested structure’s frequency resonance is 0.46 GHz. An 18 MHz frequency shift is added to the initial resonance after the pans are printed. They monitor the S-parameters in terms of S12 regarding the change in water content in the urine samples, allowing for the sensing component to be completed. As a result, 10 different samples with varying urine percentages are added to the suggested sensor to evaluate its ability to detect the presence of urine. Finally, it is discovered that the suggested process’ measurements and corresponding simulated outcomes agreed quite well.