In an attempt to improve the poor electron conductivity of CeO2 as the catalyst support and enhance the activity and long-term durability of the Pt/CeO2 catalyst, a novel catalyst has been developed based on in situ carbonization of ionic liquid to provide an N-doped carbon layer for the Pt/CeO2 catalyst. X-ray diffraction, energy dispersive analysis of X-ray, high resolution transmission electron microscopy, electron energy loss spectroscopy, scanning transmission electron microscopy-energy dispersive spectroscopy elemental mapping, cyclic voltammetry and accelerated aging tests have been performed to characterize the catalyst. The as-prepared Pt/CeO2 catalyst coated with ionic liquid showed significantly enhanced electrochemically active specific surface areas, and superior activity and durability compared to the uncoated Pt/CeO2 catalyst for methanol oxidation, which may be attributed to the reasons as follows: the pyridine-like and pyrrole-like nitrogen with the enhanced π-bonding in N-doped carbon layers greatly enhance the electrical conductivity of the CeO2 support through a change in the electronic delocalization effect of carbon atoms and a decrease in the loss of electron transfer energy; the surface of the coated CeO2 support contains more active sites for Pt deposition and reduces the surface energy with more uniform Pt dispersion; the lone pair electrons of the N atoms can form a delocalized conjugated system with the sp2-hybridized carbon frameworks and strengthen the support–metal interactions; the increase of Lewis basicity of the CeO2 surface results in strong anchoring of Pt to CeO2; the increase of Pt(0) composition during the carbonization of ionic liquid. Different contents of ionic liquid coating the CeO2 support were also investigated and the optimal content is 15 μL.
As a fast and non-destructive spectroscopic analysis technique, Raman spectroscopy has been widely applied in chemistry. However, noise is usually unavoidable in Raman spectra. Hence, denoising is an important step before Raman spectral analysis. A novel spectral denoising method based on variational mode decomposition (VMD) was introduced to solve the above problem. The spectrum is decomposed into a series of modes (uk) by VMD. Then, the high-frequency noise modes are removed and the remaining modes are reconstructed to obtain the denoised spectrum. The proposed method was verified by two artificial noised signals and two Raman spectra of inorganic materials, i.e., MnCo ISAs/CN and Fe-NCNT. For comparison, empirical mode decomposition (EMD), Savitzky–Golay (SG) smoothing, and discrete wavelet transformation (DWT) are also investigated. At the same time, signal-to-noise ratio (SNR) was introduced as evaluation indicators to verify the performance of the proposed method. The results show that compared with EMD, VMD can significantly improve mode mixing and the endpoint effect. Moreover, the Raman spectrum by VMD denoising is more excellent than that of EMD, SG smoothing and DWT in terms of visualization and SNR. For the small sharp peaks, some information is lost after denoising by EMD, SG smoothing, DWT and VMD while VMD loses fewest information. Therefore, VMD may be an alternative method for Raman spectral denoising.
1 January 2016 in Nanomaterials and Nanotechnology
A fluorescence resonance energy transfer (FRET)- based aptamer biosensor (aptasensor) for sensitive determination of adenosine triphosphate (ATP) was developed. The energy donor and acceptor were 5′-carboxyfluorescein (5′-FAM) and gold nanoparticles (AuNPs), respectively. AuNPs were linked to 3′-SH-DNA by Au-S bond. This aptasensor was obtained by the hybridization between the complementary DNA strands of the 5′-FAM and AuNPs. The detecting results indicated that the FRET increase efficiency (Fr) of detecting system at 519 nm was linear when the concentration of ATP target was about 0.1–10 mmol/L. Moreover, the aptasensors showed a good stability in different buffer conditions and a low- detection limit (15.2 nmol/L) for ATP.