Aída Lucía Fajardo-Montiel

Aída Lucía Fajardo-Montiel


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 May 2025 in Processes
Verified
Journal Article
Open access
PDF file
RPRafael González Pérez
Rafael González Pérez
AFAída Lucía Fajardo-Montiel
Aída Lucía Fajardo-Montiel
Edgardo Martinez OrozcoEdgardo Martinez Orozco
Edgardo Martinez Orozco
NSNorberto Santiago-Olivares
Norberto Santiago-Olivares
Juan Nápoles ArmentaJuan Nápoles Armenta
Juan Nápoles Armenta
Celestino García GómezCelestino García Gómez
Celestino García Gómez
The tequila industry faces several environmental challenges due to its high yields of contaminants, especially tequila distillation stillage or tequila vinasses, with ten to twelve liters produced per liter of tequila. All treatments aim to shorten retention times to avoid the need for large equipment or new facilities and the saturation of residues within tequila distilleries. The complexity of tequila vinasses has led to treatments with several stages, whereby most of the organic matter content is reduced, but the treatment range results are insufficient. This study aimed to evaluate a fourth-stage tequila vinasse treatment using an electrocoagulation system that uses inexpensive electrodes (SS cathodes and iron anodes), has a low electrical consumption, and applies low voltages in order to meet safety, economic, and environmental criteria so as to comply with Mexican norm NOM-001-SEMARNAT-2021. Three sets of voltage–amperage controllable power source, a 4 mm cylindrical 304 stainless-steel cathode, and a 9 mm iron anode with 200 mL samples in 250 mL beakers were used; three replicas (R1, R2, and R3) underwent 2 h treatment at 1–6 volts to evaluate the voltage effect and 1–6 h of 5-volt treatment to assess the time effect. All samples were filtered with 8 μm and 0.25 μm meshes. Chemical oxygen demand, pH, electrical conductivity, turbidity, and color measurements (SAC for λ 436, 525, and 620 nm) were taken. The experiments determined the optimal voltage and time, considering a hydraulic retention time below 6 h. The results show that electrocoagulation of pretreated tequila vinasses effectively helps in the final removal of organic matter measured as COD, reaching values below 150 COD mg/L at 5–6 h with 5 V treatments and color reduction with 5 V, 1 h treatment. This leads to final polishing that complies with the Mexican wastewater discharge norm criteria.

1 September 2021
Verified
Book Chapter
Open access
PDF file
MGMario García
Mario García
HGHector Hugo Ulloa Godinez
Hector Hugo Ulloa Godinez
OGOmar García
Omar García
HRHermes Ramírez
Hermes Ramírez
AFAída Lucía Fajardo-Montiel
Aída Lucía Fajardo-Montiel
YRYamilet Rodríguez
Yamilet Rodríguez
Actively caring for the environment is an issue that prevails in the international debate, and our country takes part on this argument. One aspect of environmental deterioration is, with no doubt, atmospheric pollution; a constant in modern societies, which, in the attempt to find growth and development, impact the natural and urban environment they inhabit. A distinctive feature of commercial and economic exchange are the strategic cities, so-called capitals, in addition to the territories where coastal tourism predominates as an engine of regional human development. In this balance, which is far from being sustainable and fair, an exponential consumer market dominates and generates the progressive increase in the use of fossil fuels. The former being emitted into the atmosphere, in such a way that they alter chemical composition and cause harmful air quality. In addition, the territory is impacted, intoxicating the soil and water, which are the final deposit. The objective of this work is to determine the temporal behavior of atmospheric pollutants in the city of Tepic, Nayarit, Mexico and to identify the dominant pollution indicators considering the international and national context. Through the statistical analysis of the databases of particles smaller than 2.5 micrometers, particles smaller than 10 micrometers and carbon monoxide, the behaviors of these pollutants in the study area were obtained. Among the most significant results, particles smaller than 2.5 micrometers showed maximum levels outside the norm almost all year round, with values ​​reaching 170 micrograms per cubic meter. On the other hand, the particles smaller than 10 micrometers presented satisfactory levels in their average behavior; however, the maximum concentrations remained outside the official Mexican standard. Regarding the analysis of CO, a behavior within the maximum permissible limits of protection for the population was reported; Nevertheless, by favoring the formation of tropospheric ozone, its contribution is significant, especially when the atmosphere is highly photo-reactive. This research can be used as a timely tool for mitigation of climate change, where the results contribute to the review and rethinking of public management of the environment towards sustainable development.