João Nuno Pinto Miranda Garcia

Prof. João Nuno Pinto Miranda Garcia

Mechanic Engineering Department, Escola Superior de Tecnologia de Setúbal/IPS Campus do IPS, Estefanilha, 2760-761 Setúbal, Portugal
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 March 2016 in Environmental Technology
Verified
Journal Article
Closed access
JGJoão Nuno Pinto Miranda Garcia
João Nuno Pinto Miranda Garcia
M. Filomena TeodoroM. Filomena Teodoro
M. Filomena Teodoro
RCR. Cerdeira
R. Cerdeira
Luís CoelhoLuís Coelho
Luís Coelho
Prashant KumarPrashant Kumar
Prashant Kumar
MCM. G. Carvalho
M. G. Carvalho
A methodology to predict PM10 concentrations in urban outdoor environments is developed based on the generalized linear models (GLMs). The methodology is based on the relationship developed between atmospheric concentrations of air pollutants (i.e. CO, NO2, NOx, VOCs, SO2) and meteorological variables (i.e. ambient temperature, relative humidity (RH) and wind speed) for a city (Barreiro) of Portugal. The model uses air pollution and meteorological data from the Portuguese monitoring air quality station networks. The developed GLM considers PM10 concentrations as a dependent variable, and both the gaseous pollutants and meteorological variables as explanatory independent variables. A logarithmic link function was considered with a Poisson probability distribution. Particular attention was given to cases with air temperatures both below and above 25°C. The best performance for modelled results against the measured data was achieved for the model with values of air temperature above 25°C compared with the model considering all ranges of air temperatures and with the model considering only temperature below 25°C. The model was also tested with similar data from another Portuguese city, Oporto, and results found to behave similarly. It is concluded that this model and the methodology could be adopted for other cities to predict PM10 concentrations when these data are not available by measurements from air quality monitoring stations or other acquisition means.

18 May 2024 in Sustainability
Verified
Journal Article
Open access
PDF file
JGJoão Nuno Pinto Miranda Garcia
João Nuno Pinto Miranda Garcia
Arian António SemedoArian António Semedo
Arian António Semedo
This study compares four feasible alternative solutions for an integrated cold storage system in the city of Tarrafal, Santiago, Cape Verde. Integrated systems using grid electricity are compared with autonomous systems generating electrical energy from renewable sources, alongside various types of refrigeration facility systems. Its objective is to assess the energy efficiency, financial feasibility, and environmental impact across four scenarios. Scenario 1 utilizes two R134a refrigeration units powered by the public grid. Scenario 2 employs a transcritical R744 (CO2) system using grid electricity. Scenario 3 incorporates R744 and autonomous renewable energy. Scenario 4 employs R744 for refrigeration with seawater heat exchange and autonomous renewable energy sources. The findings favor Scenario 4, emitting 15,882 kg CO2 eq with a 5-year return on investment. Autonomous electricity production in this scenario reduces emissions by 95%. Despite an initial cost of EUR 769,172.00, Scenario 3 demonstrates financial viability, contributing to energy sustainability. This autonomous production reduces emissions by 360,697 kg CO2 compared to conventional systems, highlighting the positive impact of local renewable energy integration.

23 July 2021 in Foods
Verified
Journal Article
Open access
PDF file
Nuno Bartolomeu AlvarengaNuno Bartolomeu Alvarenga
Nuno Bartolomeu Alvarenga
JMJoao Martins
Joao Martins
JCJosé Jasnau Caeiro
José Jasnau Caeiro
JGJoão Nuno Pinto Miranda Garcia
João Nuno Pinto Miranda Garcia
JPJoão Pássaro
João Pássaro
JDJoão Dias
João Dias
Traditional ewe’s cheese producers face certain challenges caused by fluctuating environmental parameters inside the ripening room, which lead to lack of homogeneity in the final product. The present research discusses the application of computer fluid dynamics for simulating the distribution of environmental parameters, predicting the airflow pattern, and identifying critical areas where such parameters could cause reduced cheese quality. A new monitoring system was developed including presence sensors, temperature and humidity dataloggers, pneumatic actuators, microcontrollers, and microcomputers connected remotely for control, data visualization, and processing. The validation of the computer simulation and monitoring system was made with a batch of 40 ewe’s cheeses distributed in three different zones inside a prototype ripening room and ripened for 35 days. At 35 days, a physical, chemical, and microbiological characterization of cheeses was made for evaluation of the influence of environmental conditions on cheese quality. The comparison between simulated and local measurements showed close agreement, especially concerning air velocity inside the stacks of cheese. The results of Pearson’s correlation analysis and PCA concluded that temperature affected the appearance of the rind, hardness, number and area occupied by holes. Humidity affected aw and mFeret. Air velocity affected pH and the circularity of gas holes.

4 September 2013 in Urban Climate
Verified
Journal Article
Closed access
JGJoão Nuno Pinto Miranda Garcia
João Nuno Pinto Miranda Garcia
RCR. Cerdeira
R. Cerdeira
NTN. Tavares
N. Tavares
Luís CoelhoLuís Coelho
Luís Coelho
Prashant KumarPrashant Kumar
Prashant Kumar
MCM.G. Carvalho
M.G. Carvalho

1 March 2016 in Applied Thermal Engineering
Verified
Journal Article
Closed access
NCNuno Costa
Nuno Costa
JGJoão Nuno Pinto Miranda Garcia
João Nuno Pinto Miranda Garcia

17 June 2019 in Sustainability
Verified
Journal Article
Open access
PDF file
JGJoão Nuno Pinto Miranda Garcia
João Nuno Pinto Miranda Garcia
ARArmando Rosa
Armando Rosa
This article is dedicated to the design, calculation and dimensioning of a small powered refrigeration system (132W) which produces ice bars (freezing) using solar thermal power, and resorts to an intermittent cycle absorption circuit with a water-ammonia mixture (H2O-NH3). The aim of this equipment is to minimize problems faced in places where there is no electric network to supply traditional refrigeration systems which preserve perishable products produced or stocked there, as well as drugs (vaccines), namely for specific regions of developing countries. The system developed can be divided into two parts. The intermittent cycle absorption refrigeration system uses a binary water-ammonia solution (H2O-NH3), where water is the absorber and the ammonia is the coolant and the thermal solar system. This is made up of CPC flat plate thermal collectors or vacuum tubes in which solar energy heats the water that circulates in the primary circuit. In the absorption circulation system, circulation occurs in a natural way due to the fluids affinity, and the temperature and pressure internal variations. This article shows the assumptions underlying the conception, calculation and dimensioning of the system’s construction.