Some existing fault location methods for distribution networks rely too much on the local wave head information of the time or frequency domain signals, making it difficult to adapt to the increasingly complex structure and operating conditions of the distribution network after the new energy access. For improvement, the travelling wave (TW) time and frequency ranges that can effectively avoid waveform distortion caused by new energy access are analysed. The one‐to‐one matching relationship between the TW waveforms in these ranges and the fault positions is revealed. A fault TW time–frequency matrix with specific time and frequency windows is constructed, and a new distribution network fault location method is proposed based on the matching technique of waveform features, which realises the accurate fault location by exploring the proportionality between the cumulative trend of the matrix energy amplitude deviation and the fault point position. Simulation test results show that the proposed method is not affected by the complex structure of distribution networks such as new energy access and overhead‐cable line mixing on fault location and flexibly transforms the fault location problem into a time–frequency TW waveform matching problem, which improves the accuracy and robustness of the fault location for new distribution networks to a degree.
Challenges are brought to high impedance fault (HIF) line selection in traditional distribution networks by the fault signals with short windows and weak characteristics provided by new energy power sources. A new method driven by the symmetry of current traveling wave spectrum is proposed in this paper. Frequency-domain features are extracted by using Pisarenko spectral decomposition, and the differences in amplitude, frequency, and polarity between faulted and healthy feeders are analyzed. A similarity matrix is constructed with the help of Manhattan distance, and an improved density-based spatial clustering of application with noise (DBSCAN) clustering is adopted to achieve intelligent fault line selection. Experimental results show that compared with the steady state component method and the transient component method, the accuracy of this method is increased to 97.5%, with an improvement of more than 12.5%. Quantitative thresholds are replaced by qualitative spectrum differences, and this method is not affected by weak signals, thus solving the problem of threshold setting caused by the access of new energy. The accuracy of this method under different fault types, phases, and resistances is verified by simulation, ensuring easy engineering implementation.
3 April 2025 in International Journal of Electrical Power & Energy Systems
The time-domain fault signal data window provided by the new energy source is short. Certain existing bus protection methods may operate incorrectly when there are loud noise interference and high-resistance fault. Here, a novel differential bus protection method is proposed by using the fault-current traveling-wave (FCTW) frequency domain. Changes in the reflection coefficient and the refraction coefficient with respect to the frequency of FCTWs (when they are reflected to the fault line and refracted to the nonfault line through the bus) are theoretically deduced. The frequency-dependent evolution mechanism of FCTWs on buses and transmission lines is revealed. Characteristic differences in the FCTW spectrum waveforms that occur between the power lines when internal and external faults occur in the bus system are accurately identified. A protection criterion is constructed using the Tanimoto coefficient (TC) because the TC construction mode and the corresponding characteristics can reliably identify the spectral waveform change trend, making the criterion largely unaffected by noise and fault resistance variations. Power systems computer aided design (PSCAD)/electromagnetic transients including direct current (EMTDC) simulation results reveal that the proposed method is faster and more sensitive than the existing protection method, particularly for protecting against internal high-resistance faults and external faults with loud noise interference. Laboratory testing verifies the effectiveness of the proposed method and it is suitable to realize the industry application with new energy access.
Power outages in non-faulted zones caused by system failures significantly reduce the reliability of distribution networks. To address this issue, this paper proposes a fault self-healing technique based on the integration of soft open points (SOPs) and network reconfiguration. A mathematical model for power restoration is developed. The model incorporates SOP operational constraints and the stochastic output of photovoltaic (PV) distributed generation. And this formulation enables the determination of the optimal network reconfiguration strategy and enhances the restoration capability. The study first analyzes the operational principles of SOPs and formulates corresponding constraints based on their voltage support and power flow regulation capabilities. The stochastic nature of PV power output is then modeled and integrated into the restoration model to enhance its practical applicability. This restoration model is further reformulated as a second-order cone programming (SOCP) problem to enable efficient computation of the optimal network configuration. The proposed method is simulated and validated in MATLAB R2019a. Results demonstrate that combining the SOP with the reconfiguration strategy achieves a 100% load restoration rate. This represents a significant improvement compared to traditional network reconfiguration methods. Furthermore, the second-order cone programming (SOCP) transformation ensures computational efficiency. The proposed approach effectively enhances both the fault recovery capability and operational reliability of distribution networks with high penetration of renewable energy.
Single‐phase ground faults can occur in distribution networks, which bring harm to the safe operation of distribution networks. With the continuous development of new energy technology, distributed power supply is also accessed to the distribution network in large quantities. This paper analysed the impact of distributed power supply from the perspective of its transient frequency response. It explores the changing rules and characteristics of the fault travelling wave in the frequency and time domains, revealing its time–frequency–amplitude three‐dimensional characteristics. Accordingly, a detection method based on energy distribution characteristics is proposed, and the thresholds for startup and fault detection are given. The sensitivity of the startup criterion and the accuracy of fault detection are verified through simulation analysis, and the method is able to identify transient disturbances and faults, and also has a certain anti‐interference ability. In addition, experimental validation was carried out in a physical test field, and the results show that the proposed method is applicable in practical application scenarios.