19 February 2025 in IEEE Transactions on Industrial Informatics
The struggling and twitching of an electrically shocked body in low-voltage distribution grids can complicate and diversify the electric shock current, posing challenges to traditional electric shock detection methods. To tackle this issue, we propose a fault identification method for animal electric shocks considering unstable contact situations. First, a low-voltage distribution network grounding fault experimental platform is established in a real system, creating a sample library that encompasses various operational scenarios. Second, based on the dynamic characteristics of contact resistance and the principles of arc breakdown generation, an electrical equivalent modeling analysis is conducted on the unstable contact region. The underlying mechanisms that increase the complexity and diversity of electric shock current are revealed. Then, innovative features such as “the sum of periodic point differences,” “energy fluctuation arrays,” “pulse regularity,” and “the count of reversals in the direction of changes” are proposed. By integrating several traditional features and automatically extracted encoded features, a feature vector for animal electric shock faults is established from the perspectives of dynamic amplitude, high-frequency components, energy, and encoded features. In addition, a light gradient boosting machine optimized by multiattraction mechanism zebra optimization has been developed. This model achieves accuracy in pattern recognition tasks through its unique ensemble computation and one-sided sampling mechanism, while also reducing time and space costs. Finally, the proposed method is compared with three existing electric shock identification methods using our experimental platform's testing set. The results indicate that the proposed method demonstrates superiority in terms of accuracy for identifying animal electric shocks.
30 April 2024 in IEEE Transactions on Power Delivery
The asymmetry of three phase-to-ground parameters is common in distribution networks, and the asymmetry of each feeder has the random difference. However, most of existing single line-to-ground (SLG) fault detection and arc suppression methods ignored the influence of asymmetry on fault protection reliability. In response to this problem, this paper firstly establishes a new zero-sequence equivalent model considering three phase-to-ground parameters asymmetry in an active flexible grounding system. Based on the zero-sequence voltage and current before and after the adjustment of the injected current in this model, the distribution characteristics of the injected current and the grounding parameters of each feeder are calculated, which can be used as the criteria for faulty feeder selection. Then, the unbalanced ground-fault current caused by the asymmetry is discovered, and the voltage-based arc suppression method is proposed to fully compensate these unbalanced components. Finally, considering the asymmetry of three phase-to-ground parameters, an SLG fault protection synchronous control strategy with a coordinated process of arc suppression and fault detection is proposed in active flexible grounding systems. The high reliability of the proposed method is confirmed by comparative experimental results with the theoretical analysis.
19 May 2025 in IEEE Journal of Emerging and Selected Topics in Power Electronics
The traditional current-type flexible arc suppression method fails to account for the impact of line voltage drop, resulting in residual current during grounding fault suppression. To improve fault current suppression performance, this article proposes flexible arc suppression method using cascaded H-bridge converters with adaptive voltage drop compensation. First, the theoretical expression for a novel injection current arc suppression algorithm is derived, incorporating the effects of line voltage drop. Subsequently, the differences between the newly developed algorithm and the original algorithm for zero-sequence voltage regulation are analyzed. Building on these differences, an injection current arc suppression algorithm with adaptive line voltage drop is constructed, enabling the realization of zero residual currents under varying ground fault conditions. Furthermore, to address the impact of variations in the equivalent load impedance of the cascaded H-bridge converter on the stability of the control system, this article proposes a controller design method that considers changes in grounding fault parameters, ensuring stable current output from the cascaded H-bridge converters. Finally, the correctness and feasibility of the proposed method are validated through PSCAD/EMTDC simulations and physical experiments.
15 December 2025 in IEEE Journal of Emerging and Selected Topics in Power Electronics
A three-phase, four-arm cascaded H-bridge (CHB) topology is proposed to reduce the power-electronic hardware required by conventional three-phase, direct-hanging flexible arc-suppression devices (FASDs), in which each arm is subjected to the line voltage. By limiting the per-arm voltage stress to the phase-to-ground level, the required cascade count is reduced. To address the limitations of flexible current arc suppression method based on proportional–integral–derivative (PID) control and linear active disturbance rejection control (LADRC)—which exhibit nonzero steady-state current-tracking error under high-resistance ground faults—as well as those of traditional flexible voltage arc suppression method—which become unreliable under low-resistance faults due to line-impedance voltage drop—a flexible fusion arc-suppression method based on sliding-mode control with an exponential reaching law (SMC-ERL) is developed. In this method, the device output current and the neutral-point voltage are regulated in parallel, simultaneously suppressing ground-fault current and voltage and mitigating the effects of fault resistance and line-impedance voltage drop. The SMC-ERL strategy enables fast and accurate tracking of the compensation-current reference. The effectiveness of the proposed approach is validated by simulation and experimental results.
17 November 2025 in IEEE Transactions on Smart Grid
Existing protection methods for DC distribution networks suffer from limitations such as low transition resistance tolerance, noise susceptibility, and inadequate speed. To overcome these challenges, this paper first establishes a bipolar short-circuit fault model that considers multi-converter interactions. Based on this model, we reveal the intrinsic relationship between fault current energy distribution and fault conditions, and propose a novel protection criterion utilizing the Energy Peak-to-Average Ratio (EPAR) of the fault current. By converting the time-domain waveform characteristics of the fault current into energy distribution features, the method effectively characterizes the influence of transition resistance on fault characteristics, enabling rapid and reliable identification of high-impedance bipolar short-circuit faults. An adaptive collaborative protection method leveraging the complementary characteristics of EPAR and current variation is developed. By constructing a dual-criterion coordination mechanism integrating current variation and EPAR, this method enables dynamic setting and complementary identification, ensuring full-line rapid protection for internal bipolar faults. Furthermore, the impact of setting value selection on protection reliability and sensitivity was quantitatively analyzed, constraints in the protection setting process were elucidated, and a theoretical basis for applying the proposed method to DC distribution networks with different structures was provided. A 10 kV multi-terminal flexible DC distribution network model incorporating diverse converters is built in PSCAD/EMTDC to validate the proposed method under various fault conditions. Simulation results demonstrate that the method accurately discriminates faults within 1.5 ms after occurrence, achieves transition resistance tolerance up to $100~\Omega $ , and exhibits strong noise immunity.
4 April 2025 in IEEE Sensors Journal
The time-domain fault signal data window provided by the new energy source is short. Certain existing bus protection methods may operate incorrectly when there are loud noise interference and high-resistance fault. Here, a novel differential bus protection method is proposed by using the fault-current traveling-wave (FCTW) frequency domain. Changes in the reflection coefficient and the refraction coefficient with respect to the frequency of FCTWs (when they are reflected to the fault line and refracted to the nonfault line through the bus) are theoretically deduced. The frequency-dependent evolution mechanism of FCTWs on buses and transmission lines is revealed. Characteristic differences in the FCTW spectrum waveforms that occur between the power lines when internal and external faults occur in the bus system are accurately identified. A protection criterion is constructed using the Tanimoto coefficient (TC) because the TC construction mode and the corresponding characteristics can reliably identify the spectral waveform change trend, making the criterion largely unaffected by noise and fault resistance variations. Power systems computer aided design (PSCAD)/electromagnetic transients including direct current (EMTDC) simulation results reveal that the proposed method is faster and more sensitive than the existing protection method, particularly for protecting against internal high-resistance faults and external faults with loud noise interference. Laboratory testing verifies the effectiveness of the proposed method and it is suitable to realize the industry application with new energy access.