Ewald Unger

Mr. Ewald Unger

orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 November 2020 in Clinical Oral Implants Research
Verified
Journal Article
Open access
PDF file
DTDino Tur
Dino Tur
KGKatharina Giannis
Katharina Giannis
EUEwald Unger
Ewald Unger
MMMartina Mittlboeck
Martina Mittlboeck
XRXiaohui Rausch-Fan
Xiaohui Rausch-Fan
GSGeorg D. Strbac
Georg D. Strbac
Objectives: The aim of this study was to evaluate thermal effects of ceramic and metal implant drills during implant site preparation using a standardised bovine model.Material and Methods: A total of 320 automated intermittent osteotomies of 10‐ and 16‐mm drilling depths were performed using zirconium dioxide‐based and stainless steel drills. Various drill diameters (2.0/ 2.2, 2.8, 3.5, 4.2 mm ∅) and different cooling methods (without/ with external saline irrigation) were investigated at room temperature (21 ± 1°C). Temperature changes were recorded in real time using two custom‐built multichannel thermoprobes in 1‐ and 2‐mm distance to the osteotomy site. For comparisons, a linear mixed model was estimated.Results: Comparing thermal effects, significantly lower temperatures could be detected with steel‐based drills in various drill diameters, regardless of drilling depth or irrigation method. Recorded temperatures for metal drills of all diameters and drilling depths using external irrigation were below the defined critical temperature threshold of 47°C, whereas ceramic drills of smaller diameters reached or exceeded the harmful temperature threshold at 16‐mm drilling depths, regardless of whether irrigation was applied or not. The results of this study suggest that the highest temperature changes were not found at the deepest point of the osteotomy site but were observed at subcortical and deeper layers of bone, depending on drill material, drill diameter, drilling depth and irrigation method.Conclusions: This standardised investigation revealed drill material and geometry to have a substantial impact on heat generation, as well as external irrigation, drilling depth and drill diameter.

8 May 2020 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
PDF file
Sepideh HatamikiaSepideh Hatamikia
Sepideh Hatamikia
GOGunpreet Oberoi
Gunpreet Oberoi
EUEwald Unger
Ewald Unger
GKGernot Kronreif
Gernot Kronreif
JKJoachim Kettenbach
Joachim Kettenbach
WBWolfgang Birkfellner
Wolfgang Birkfellner
Conventional medical imaging phantoms are limited by simplified geometry and radiographic skeletal homogeneity, which confines their usability for image quality assessment and radiation dosimetry. These challenges can be addressed by additive manufacturing technology, colloquially called 3D printing, which provides accurate anatomical replication and flexibility in material manipulation. In this study, we used Computed Tomography (CT)-based modified PolyJetTM 3D printing technology to print a hollow thorax phantom simulating skeletal morphology of the patient. To achieve realistic heterogenous skeletal radiation attenuation, we developed a novel radiopaque amalgamate constituting of epoxy, polypropylene and bone meal powder in twelve different ratios. We performed CT analysis for quantification of material radiodensity (in Hounsfield Units, HU) and for identification of specific compositions corresponding to the various skeletal structures in the thorax. We filled the skeletal structures with their respective radiopaque amalgamates. The phantom and isolated 3D printed rib specimens were rescanned by CT for reproducibility tests regarding verification of radiodensity and geometry. Our results showed that structural densities in the range of 42–705HU could be achieved. The radiodensity of the reconstructed phantom was comparable to the three skeletal structures investigated in a real patient thorax CT: ribs, ventral vertebral body and dorsal vertebral body. Reproducibility tests based on physical dimensional comparison between the patient and phantom CT-based segmentation displayed 97% of overlap in the range of 0.00–4.57 mm embracing the anatomical accuracy. Thus, the additively manufactured anthropomorphic thorax phantom opens new vistas for imaging- and radiation-based patient care in precision medicine.

28 December 2022 in Physica Medica
Verified
Journal Article
Closed access
Sepideh HatamikiaSepideh Hatamikia
Sepideh Hatamikia
IGIngo Gulyas
Ingo Gulyas
WBWolfgang Birkfellner
Wolfgang Birkfellner
GKGernot Kronreif
Gernot Kronreif
AUAlexander Unger
Alexander Unger
ARAndreas Renner
Andreas Renner

3 April 2020 in European Radiology
Verified
Journal Article
Closed access
PDF file
MLMatthias Lazar
Matthias Lazar
HRHelmut Ringl
Helmut Ringl
PBPascal A.T. Baltzer
Pascal A.T. Baltzer
DTDaniel Toth
Daniel Toth
CSChristian Seitz
Christian Seitz
MTMichael Toepker
Michael Toepker

27 November 2020 in Frontiers in Veterinary Science
Verified
Journal Article
Open access
PDF file
GOGunpreet Oberoi
Gunpreet Oberoi
MEM. C. Eberspächer-Schweda
M. C. Eberspächer-Schweda
SHSepideh Hatamikia
Sepideh Hatamikia
MKMarkus Königshofer
Markus Königshofer
DBDoris Baumgartner
Doris Baumgartner
EUEwald Unger
Ewald Unger
Rabbit inhalation anesthesia by endotracheal intubation involves a higher risk among small animals owing to several anatomical and physiological features, which is pathognomonic to this species of lagomorphs. Rabbit-specific airway devices have been designed to prevent misguided intubation attempts. However, it is believed that expert anesthetic training could be a boon in limiting the aftermaths of this procedure. Our research is aimed to develop a novel biomimetic 3D printed rabbit airway model with representative biomechanical material behavior and radiodensity. Imaging data were collected for two sacrificed rabbit heads using micro-computed tomography (μCT) and micro-magnetic resonance imaging for the first head and cone beam computed tomography (CBCT) for the second head. Imaging-based life-size musculoskeletal airway models were printed using polyjet technology with a combination of hard and soft materials in replicates of three. The models were evaluated quantitatively for dimensional accuracy and radiodensity and qualitatively using digital microscopy and endoscopy for technical, tactic, and visual realism. The results displayed that simulation models printed with polyjet technology have an overall surface representation of 93% for μCT-based images and 97% for CBCT-based images within a range of 0.0–2.5 mm, with μCT showing a more detailed reproduction of the nasotracheal anatomy. Dimensional discrepancies can be caused due to inadequate support material removal and due to the limited reconstruction of microstructures from the imaging on the 3D printed model. The model showed a significant difference in radiodensities in hard and soft tissue regions. Endoscopic evaluation provided good visual and tactile feedback, comparable to the real animal. Overall, the model, being a practical low-cost simulator, comprehensively accelerates the learning curve of veterinary nasotracheal intubation and paves the way for 3D simulation-based image-guided interventional procedures.

14 March 2024 in Journal of Imaging Informatics in Medicine
Verified
Journal Article
Open access
PDF file
MBMartin Bittner-Frank
Martin Bittner-Frank
ASAndreas Strassl
Andreas Strassl
EUEwald Unger
Ewald Unger
Lena HirtlerLena Hirtler
Lena Hirtler
BEBarbara Eckhart
Barbara Eckhart
EBEmir Benca
Emir Benca
The introduction of three-dimensional (3D) printed anatomical models has garnered interest in pre-operative planning, especially in orthopedic and trauma surgery. Identifying potential error sources and quantifying their effect on the model dimensional accuracy are crucial for the applicability and reliability of such models. In this study, twenty radii were extracted from anatomic forearm specimens and subjected to osteotomy to simulate a defined fracture of the distal radius (Colles’ fracture). Various factors, including two different computed tomography (CT) technologies (energy-integrating detector (EID) and photon-counting detector (PCD)), four different CT scanners, two scan protocols (i.e., routine and high dosage), two different scan orientations, as well as two segmentation algorithms were considered to determine their effect on 3D model accuracy. Ground truth was established using 3D reconstructions of surface scans of the physical specimens. Results indicated that all investigated variables significantly impacted the 3D model accuracy (p < 0.001). However, the mean absolute deviation fell within the range of 0.03 ± 0.20 to 0.32 ± 0.23 mm, well below the 0.5 mm threshold necessary for pre-operative planning. Intra- and inter-operator variability demonstrated fair to excellent agreement for 3D model accuracy, with an intra-class correlation (ICC) of 0.43 to 0.92. This systematic investigation displayed dimensional deviations in the magnitude of sub-voxel imaging resolution for all variables. Major pitfalls included missed or overestimated bone regions during the segmentation process, necessitating additional manual editing of 3D models. In conclusion, this study demonstrates that 3D bone fracture models can be obtained with clinical routine scanners and scan protocols, utilizing a simple global segmentation threshold, thereby providing an accurate and reliable tool for pre-operative planning.