Background—: Recent evolution of cardiac computed tomography (CT) provides useful information about valvular and perivalvular structures. We compared the diagnostic performance of CT and transesophageal echocardiography (TEE) with applications of 3-dimensional reconstruction in detecting vegetation and intracardiac complications in patients with infective endocarditis (IE). Methods and Results—: Seventy-five patients (53 men; age, 58±15 years) with definite IE who underwent TEE and CT with 3-dimensional reconstruction within 3 days were analyzed. The diagnostic performances of the 2 modalities for vegetation and IE-related intracardiac complications (valve perforation, valve aneurysm, perivalvular abscess, pseudoaneurysm, fistula, and prosthetic valve dehiscence) were compared. The detection rate of vegetation in TEE and CT was 97.3% and 72.0%, respectively. The maximum sizes of vegetation identified by TEE and CT were well correlated ( r =0.593; P <0.001), especially in patients with large vegetation (≥10 mm), suggestive of a high risk of systemic embolism ( r =0.608; P <0.001). However, small vegetation (<10 mm) was underdiagnosed by CT (52.8%) compared with TEE (94.4%), and the sizes of the 2 modalities were poorly correlated ( r =0.187; P =0.445). Both modalities showed fair diagnostic performance for detecting IE-related intracardiac complications with excellent agreement. TEE was more useful for diagnosing valve perforation and intracardiac fistula, whereas CT was better for diagnosing perivalvular abscess. Conclusions—: Cardiac CT shows a comparable diagnostic performance with TEE for large vegetation and several IE-related complications. TEE is better for detecting small vegetation, valve perforation, and intracardiac fistula, whereas CT is more useful for detecting perivalvular abscess and coronary artery disease.
1 January 2010 in Clinical and Experimental Otorhinolaryngology
The objective of this study was to review our experience in the surgical management of carotid body paragangliomas and evaluate the outcomes and complications according to the Shamblin classification. Thirteen patients who had been diagnosed and surgically treated for carotid body tumors (CBTs) were enrolled in this study. We reviewed patient demographics, radiographic findings, and surgical outcomes collected from medical records. Fifteen CBTs were found in 13 patients and 13 tumors were resected. Selective preoperative tumor embolization was performed on six patients. The median blood loss, operation time, and hospital stay for these patients were not significantly reduced compared to those without embolization. The median tumor size was 2.3 cm in Shamblin I and II and 4 cm in Shamblin III. The median intraoperative blood loss was 280 mL and 700 mL, respectively (P<0.05). Internal carotid artery ligation with reconstruction was accomplished on three patients (23%), and they all belonged to Shamblin III (38%). One Shamblin III patient (8%) developed transient cerebral ischemia, and postoperative stroke with death occurred in another Shamblin III patient. Postoperative permanent cranial nerve deficit occurred in three patients (23%) who were all in Shamblin III (P=0.03). There were no recurrences or delayed complications at the median follow up of 29 months. Shamblin III had a high risk of postoperative neurovascular complications. Therefore, early detection and prompt surgical resection of CBTs will decrease surgical morbidity.
1 April 2010 in The Journal of Thoracic and Cardiovascular Surgery
The in situ diagnosis of cardiac activities with simultaneous therapeutic electrical stimulation of the heart is key to preventing cardiac arrhythmia. Here, we present an unconventional single-device platform that enables in situ monitoring even in a wet condition and control of beating heart motions without interferences to the recording signal. This platform consists of the active-matrix array of pressure-sensitive transistors for detecting cardiac beatings, biocompatible, low-impedance electrodes for cardiac stimulations, and an alginate-based hydrogel adhesive for attaching this platform conformally to the epicardium. In contrast to conventional electrophysiological sensing using electrodes, the pressure-sensitive transistors measured mechanophysiological characteristics by monitoring the spatiotemporal distributions of cardiac pressures during heart beating motions. In vivo tests show mechanophysiological readings having good correlation with electrocardiography and negligible interference with the electrical artifacts caused during cardiac stimulations. This platform can therapeutically synchronize the rhythm of abnormal heartbeats through efficient pacing of cardiac arrhythmia.