High-resolution spectral analysis of a multimode GaN-based blue laser diode was performed as a function of temperature and current both below and above the threshold levels. Maps of longitudinal modes evolution as a function of current and temperature were obtained from the highly resolved emission spectra of the laser diode. The evolution of emitted longitudinal modes with current and temperature exhibited redshifts at rates of 0.0059 nm/mA and 0.0149 nm/°C, respectively. Similarly, the laser gain profile was observed to shift towards longer wavelengths but with rates of 0.022 nm/mA and 0.0439 nm/°C. The longitudinal mode spacing of 0.0540 nm was experimentally evaluated and compared with its equivalent theoretically predicted value.
In this paper, we present a new technique to study the dynamics of a free-falling object in a lab setting and to measure the acceleration due to gravity g using a simple and economic setup. The precise measurement of time taken for an object to fall freely passing an infrared (IR) transceiver is utilized to deduce the acceleration due to gravity. The reflected IR intensity from a free-falling 0.19 m rod of equally spaced white stripes of 0.01 m is detected and sent to a digital oscilloscope to observe and record the falling time period of each stripe. By fitting recorded elapsed falling times to the well-known quadratic equation of motion under constant acceleration, an accurate value of the acceleration due to gravity of g = 9.8092 ± 0.0384 m s−2 is obtained. In addition to its accuracy, the proposed technique is safer and more economic than most of the other currently used setups to determine g in undergraduate teaching labs. This study may provide undergraduate lab instructors with an efficient teaching technique for a traditional classroom experiment.
The full details of a newly developed versatile, portable and low-cost magneto-optical device for the accurate determination of Verdet constant over the wavelength range of 400–480 nm in undergraduate physics and chemistry labs are presented. The elevated sensitivity of the device is achieved by using a semiconducting photodiode detector coupled with an electronic circuit board, which is configured to autonomously record the finest rotation angle in the polarization direction of the transmitted light relative to a reference polarizer. Two different mechanisms to generate a strong coaxial magnetic field of ∼1.34 T are presented, using either a ring neodymium permanent magnet or a solenoid fed by a lithium-ion battery cell. Due to its versatility, portability and low-cost, the presented device is expected to replace most currently existing bulky and expensive setups.