Muaiyed Mahmoud Buzayan

Dr. Muaiyed Mahmoud Buzayan

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 December 2013 in The Journal of Indian Prosthodontic Society
Verified
Journal Article
Open access
PDF file
MBMuaiyed Mahmoud Buzayan
Muaiyed Mahmoud Buzayan
NYNorsiah Binti Yunus
Norsiah Binti Yunus
One of the considerable challenges for screw-retained multi-unit implant prosthesis is achieving a passive fit of the prosthesis’ superstructure to the implants. This passive fit is supposed to be one of the most vital requirements for the maintenance of the osseointegration. On the other hand, the misfit of the implant supported superstructure may lead to unfavourable complications, which can be mechanical or biological in nature. The manifestations of these complications may range from fracture of various components in the implant system, pain, marginal bone loss, and even loss of osseointegration. Thus, minimizing the misfit and optimizing the passive fit should be a prerequisite for implant survival and success. The purpose of this article is to present and summarize some aspects of the passive fit achieving and improving methods. The literature review was performed through Science Direct, Pubmed, and Google database. They were searched in English using the following combinations of keywords: passive fit, implant misfit and framework misfit. Articles were selected on the basis of whether they had sufficient information related to framework misfit’s related factors, passive fit and its achievement techniques, marginal bone changes relation with the misfit, implant impression techniques and splinting concept. The related references were selected in order to emphasize the importance of the passive fit achievement and the misfit minimizing. Despite the fact that the literature presents considerable information regarding the framework’s misfit, there was not consistency in literature on a specified number or even a range to be the acceptable level of misfit. On the other hand, a review of the literature revealed that the complete passive fit still remains a tricky goal to be achieved by the prosthodontist.

1 January 2013 in The International Journal of Oral and Maxillofacial Implants
Verified
Journal Article
Open access
MBMuaiyed Mahmoud Buzayan
Muaiyed Mahmoud Buzayan
MBMirza Rustum Baig
Mirza Rustum Baig
NYNorsiah Yunus
Norsiah Yunus
Muaiyed Buzayan, MClin Dent/Mirza Rustum Baig, MDS/Norsiah Yunus, BDS, MSc: Purpose: This in vitro study evaluated the accuracy of multiple-unit dental implant casts obtained from splinted or nonsplinted direct impression techniques using various splinting materials by comparing the casts to the reference models. The effect of two different impression materials on the accuracy of the implant casts was also evaluated for abutment-level impressions. Materials and Methods: A reference model with six internal-connection implant replicas placed in the completely edentulous mandibular arch and connected to multi-base abutments was fabricated from heat-curing acrylic resin. Forty impressions of the reference model were made, 20 each with polyether (PE) and polyvinylsiloxane (PVS) impression materials using the open tray technique. The PE and PVS groups were further subdivided into four subgroups of five each on the bases of splinting type: no splinting, bite registration PE, bite registration addition silicone, or autopolymerizing acrylic resin. The positional accuracy of the implant replica heads was measured on the poured casts using a coordinate measuring machine to assess linear differences in interimplant distances in all three axes. The collected data (linear and three-dimensional [3D] displacement values) were compared with the measurements calculated on the reference resin model and analyzed with nonparametric tests (Kruskal-Wallis and Mann-Whitney). Results: No significant differences were found between the various splinting groups for both PE and PVS impression materials in terms of linear and 3D distortions. However, small but significant differences were found between the two impression materials (PVS, 91 μm; PE, 103 μm) in terms of 3D discrepancies, irrespective of the splinting technique employed. Conclusions: Casts obtained from both impression materials exhibited differences from the reference model. The impression material influenced impression inaccuracy more than the splinting material for multiple-unit abutment-level impressions.

1 April 2013 in Journal of Prosthodontics
Verified
Journal Article
Open access
PDF file
MBMuaiyed Mahmoud Buzayan
Muaiyed Mahmoud Buzayan
YAYusnidar T. Ariffin
Yusnidar T. Ariffin
NYNorsiah Yunus
Norsiah Yunus
A method is described for the fabrication of a closed hollow bulb obturator prosthesis using a hard thermoforming splint material and heat-cured acrylic resin. The technique allowed the thickness of the thermoformed bulb to be optimized for weight reduction, while the autopolymerized seal area was covered in heat-cured acrylic resin, thus eliminating potential leakage and discoloration. This technique permits the obturator prosthesis to be processed to completion from the wax trial denture without additional laboratory investing, flasking, and processing.

31 December 2020 in Dental and Medical Problems
Verified
Journal Article
Open access
EEEnas Abdalla Etajuri
Enas Abdalla Etajuri
ESEshamsul Suliman
Eshamsul Suliman
WMWan Adida Azina Mahmood
Wan Adida Azina Mahmood
NINorliza Ibrahim
Norliza Ibrahim
MBMuaiyed Mahmoud Buzayan
Muaiyed Mahmoud Buzayan
NMNoorhayati Raja Mohd
Noorhayati Raja Mohd
There is very little literature available on the reliability of the rapid prototyping technology in the production of three-dimension (3D)-printed surgical guides for accurate implant placement. The aim of the study was to evaluate the deviation of implant placement performed with a surgical guide fabricated by means of the rapid prototyping technique (the PolyJet™ technology). Twenty sheep mandibles were used in the study. Pre-surgical cone-beam computed tomography (CBCT) scans were acquired for the mandibles by using the Kodak 9000 3D cone-beam system. Two implants with dimensions of 4 mm in diameter and 10 mm in length were virtually planned on the 3D models of each mandible by using the Mimics software, v. 16.0. Twenty surgical guides were designed and printed using the PolyJet technology. A total of 40 implants were placed using the surgical guides, 1 on each side of the mandible (2 implants per mandible). The post-surgical CBCT scans of the mandibles were performed and superimposed on the pre-surgical CBCT scans. The amount of deviation between the virtually planned placement and the actual implant placement was measured, and a descriptive analysis was done. The results showed that the mean deviation at the implant coronal position was 1.82 ±0.74 mm, the mean deviation at the implant apex was 1.54 ±0.88 mm, the mean depth deviation was 0.44 ±0.32 mm, and the mean angular deviation was 3.01 ±1.98°. The deviation of dental implant placement performed with a 3D-printed surgical guide (the PolyJet technology) is within the acceptable 2-millimeter limit reported in the literature.

1 June 2021 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
ISIndumathi Sivakumar
Indumathi Sivakumar
SASivakumar Arunachalam
Sivakumar Arunachalam
SCSuchismita Choudhary
Suchismita Choudhary
MBMuaiyed Mahmoud Buzayan
Muaiyed Mahmoud Buzayan

23 September 2023 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
MBMuaiyed Mahmoud Buzayan
Muaiyed Mahmoud Buzayan
AEAeman H. Elkezza
Aeman H. Elkezza
SASiti Fauzza Ahmad
Siti Fauzza Ahmad
NSNosizana Mohd Salleh
Nosizana Mohd Salleh
ISIndumathi Sivakumar
Indumathi Sivakumar