Eshamsul Sulaiman

Eshamsul Sulaiman

Auto-generated profile, based on publicly available information

Eshamsul Sulaiman

Faculty of Dentistry, Department of Restorative Dentistry University of Malaya Kuala Lumpur Malaysia

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 November 2022 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
AAAly Abdelrehim
Aly Abdelrehim
EEEnas Abdalla Etajuri
Enas Abdalla Etajuri
ESEshamsul Sulaiman
Eshamsul Sulaiman
HSHazrina Sofian
Hazrina Sofian
NSNosizana Mohd Salleh
Nosizana Mohd Salleh

31 December 2020 in Dental and Medical Problems
Verified
Journal Article
Open access
EEEnas Abdalla Etajuri
Enas Abdalla Etajuri
ESEshamsul Suliman
Eshamsul Suliman
WMWan Adida Azina Mahmood
Wan Adida Azina Mahmood
NINorliza Ibrahim
Norliza Ibrahim
MBMuaiyed Mahmoud Buzayan
Muaiyed Mahmoud Buzayan
NMNoorhayati Raja Mohd
Noorhayati Raja Mohd
There is very little literature available on the reliability of the rapid prototyping technology in the production of three-dimension (3D)-printed surgical guides for accurate implant placement. The aim of the study was to evaluate the deviation of implant placement performed with a surgical guide fabricated by means of the rapid prototyping technique (the PolyJet™ technology). Twenty sheep mandibles were used in the study. Pre-surgical cone-beam computed tomography (CBCT) scans were acquired for the mandibles by using the Kodak 9000 3D cone-beam system. Two implants with dimensions of 4 mm in diameter and 10 mm in length were virtually planned on the 3D models of each mandible by using the Mimics software, v. 16.0. Twenty surgical guides were designed and printed using the PolyJet technology. A total of 40 implants were placed using the surgical guides, 1 on each side of the mandible (2 implants per mandible). The post-surgical CBCT scans of the mandibles were performed and superimposed on the pre-surgical CBCT scans. The amount of deviation between the virtually planned placement and the actual implant placement was measured, and a descriptive analysis was done. The results showed that the mean deviation at the implant coronal position was 1.82 ±0.74 mm, the mean deviation at the implant apex was 1.54 ±0.88 mm, the mean depth deviation was 0.44 ±0.32 mm, and the mean angular deviation was 3.01 ±1.98°. The deviation of dental implant placement performed with a 3D-printed surgical guide (the PolyJet technology) is within the acceptable 2-millimeter limit reported in the literature.

24 March 2017 in Journal of Medical and Biological Engineering
Verified
Journal Article
Closed access
PDF file
MIMuhammad Ikman Ishak
Muhammad Ikman Ishak
ASAisyah Ahmad Shafi
Aisyah Ahmad Shafi
MKMohammed Rafiq Abdul Kadir
Mohammed Rafiq Abdul Kadir
ESEshamsul Sulaiman
Eshamsul Sulaiman

1 January 2018 in Surface and Coatings Technology
Verified
Journal Article
Closed access
FFFiras Abdulameer Farhan
Firas Abdulameer Farhan
ESEshamsul Sulaiman
Eshamsul Sulaiman
MKMuralithran G. Kutty
Muralithran G. Kutty

1 October 2011 in Applied Mechanics and Materials
Verified
Journal Article
Closed access
PDF file
AOAisyah Omar
Aisyah Omar
MIMuhammad Ikman Ishak
Muhammad Ikman Ishak
MHMuhamad Noor Harun
Muhamad Noor Harun
ESEshamsul Sulaiman
Eshamsul Sulaiman
NKNoor Hayaty Abu Kasim
Noor Hayaty Abu Kasim
Orthodontic is one of the treatments in dentistry field which concerned on malocclusion treatments such as improper bites, tooth irregularity and disproportionate jaw relationships. The mini-implant (OMI) is one of the components used in the orthodontic treatment, besides braces and spring. The application of OMI has been well accepted in orthodontic treatment. However, one of the main factors of OMI failures is the implant insertion procedure in which the clinician find it difficult to obtain the best angle to insert the OMI. Therefore, this study aims to evaluate stress in an OMI and bones using the finite element analysis (FEA) with variations of insertion angles and to identify their optimal angle for the implant placement. The three dimensional (3D) model of a left maxillary posterior bone section was constructed based on CT image dataset. That 3D model consists of cortical bone, cancellous bone, second premolar, first molar and second molar teeth. The 3D model of OMI was placed between root of second premolar and first molar teeth. The OMI was simulated with seven different angles of insertions: 30˚, 40˚, 50˚, 60˚, 70˚, 80˚ and 90˚. Within the seven different insertion angles, the results showed that the increase of insertion angle reduced the maximum equivalent von Mises stress in cortical bone, cancellous bone and OMI. Based on this FEA study, the optimal angle placement of OMI is when the implant positioned at vertical angle (90˚) to the bone surface.

31 July 2023 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Verified
Journal Article
Closed access
MAMustafa N. W. N. A.
Mustafa N. W. N. A.
ARAhmad R.
Ahmad R.
NANur Hafizah Kamar Affendi
Nur Hafizah Kamar Affendi
SESulaiman E.
Sulaiman E.
KAKhushaini M. A. A.
Khushaini M. A. A.
MSMOHD ZAKI SALLEH
MOHD ZAKI SALLEH