Qi Yuan

Dr. Qi Yuan


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 October 2022 in Materials
Verified
Journal Article
Open access
PDF file
HPHaoying Pang
Haoying Pang
LFLiu Feng
Liu Feng
WFWenfeng Fan
Wenfeng Fan
JWJiaqi Wu
Jiaqi Wu
QYQi Yuan
Qi Yuan
WQWei Quan
Wei Quan
The ferrite magnetic shield is widely used in ultra-high-sensitivity atomic sensors because of its low noise characteristics. However, its noise level varies with temperature and affects the performance of the spin-exchange relaxation-free (SERF) co-magnetometer. Therefore, it is necessary to analyze and suppress the thermal magnetic noise. In this paper, the thermal magnetic noise model of a ferrite magnetic shield is established, and the thermal magnetic noise of ferrite is calculated more accurately by testing the low-frequency complex permeability at different temperatures. A temperature suppression method based on the improved heat dissipation efficiency of the ferrite magnetic shield is also proposed. The magnetic noise of the ferrite is reduced by 46.7%. The experiment is basically consistent with the theory. The sensitivity of the co-magnetometer is decreased significantly, from 1.21 × 10−5°/s/Hz1/2 to 7.02 × 10−6°/s/Hz1/2 at 1 Hz. The experimental results demonstrate the effectiveness of the proposed method. In addition, the study is also helpful for evaluating the thermal magnetic noise of other materials.

29 May 2025 in Photonics
Verified
Journal Article
Open access
PDF file
QYQi Yuan
Qi Yuan
WFWenfeng Fan
Wenfeng Fan
HPHaoying Pang
Haoying Pang
XHXue Han
Xue Han
ZWZhuo Wang
Zhuo Wang
WQWei Quan
Wei Quan
The beam angle error of the pump light in a K-Rb-21Ne spin-exchange relaxation-free atomic co-magnetometer (SERFCM) significantly degrades the efficiency of optical pumping and the system’s ability to suppress magnetic field noise. In this work, a system response model that incorporates the pump beam alignment error (PBAE) is established. The influence of PBAE on the scale factor, bandwidth, and magnetic noise response of the inertial output is analyzed. Theoretical results show that PBAE increases the internal magnetic field gradient, reduces the efficiency of nuclear spin hyperpolarization, and increases the nuclear spin relaxation rate, ultimately degrading the system’s scale factor, bandwidth, and magnetic noise suppression capability. Experimental results demonstrate that, compared to the original SERFCM with PBAE, aligning the pump laser using the proposed method improves the polarization strength of nuclear spins by approximately 10% and enhances magnetic noise suppression by 40%.

14 September 2026 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
XLXiaoping Li
Xiaoping Li
WFWenfeng Fan
Wenfeng Fan
HGHang Gao
Hang Gao
SFShimiao Fan
Shimiao Fan
QYQi Yuan
Qi Yuan
WQWei Quan
Wei Quan
The magnetic dynamics at the nanoscale interface of amorphous insulators sit at the intersection of advancing ultrasensitive quantum sensing and understanding condensed matter physics. While noble-gas spin relaxation offers a powerful approach to probe these interfaces, it has long been restricted to probing bulk paramagnetic backgrounds due to the deep penetration depths of traditional dipolar probes. In this Letter, we report the observation of nanotesla-level magnetic hysteresis and thermally activated relaxation growth in aluminosilicate glass cells using $^{21}\mathrm{Ne}$ as a quadrupolar-enhanced quantum probe. The strong coupling between the nuclear electric quadrupole moment and the surface electric field gradient compresses the effective spin sampling depth to the nanometer scale [$\ensuremath{\sim}\mathcal{O}(1)\text{ }\text{ }\mathrm{nm}$]. By coupling Jiles-Atherton hysteresis dynamics with Cates diffusion and accounting for gas-phase thermal line broadening, we obtain a cross-cell average apparent activation energy of $⟨{E}_{\mathrm{act}}⟩\ensuremath{\approx}49.7\text{ }\text{ }\mathrm{kJ}/\mathrm{mol}$ within the present relaxation model. The pronounced field-history dependence of the relaxation is consistent with localized magnetic inhomogeneity at the glass interface. The proposed methodology provides an in situ, nondestructive, depth-selective probe of magnetic behavior at otherwise inaccessible amorphous glass interfaces, with potential utility for identifying wall-related relaxation in ultrasensitive comagnetometers.