Hang Gao

Hang Gao

Auto-generated profile, based on publicly available information

Hang Gao

Beihang University

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 November 2022 in Materials
Verified
Journal Article
Open access
PDF file
YLYe Liu
Ye Liu
HGHang Gao
Hang Gao
LMLongyan Ma
Longyan Ma
JQJiale Quan
Jiale Quan
WFWenfeng Fan
Wenfeng Fan
WQWei Quan
Wei Quan
With the widespread use of magneto-sensitive elements, magnetic shields are an important part of electronic equipment, ultra-sensitive atomic sensors, and in basic physics experiments. Particularly in Spin-exchange relaxation-free (SERF) co-magnetometers, the magnetic shield is an important component for maintaining the SERF state. However, the inherent noise of magnetic shield materials is an important factor limiting the measurement sensitivity and accuracy of SERF co-magnetometers. In this paper, both amorphous and nanocrystalline materials were designed and applied as the innermost magnetic shield of an SERF co-magnetometer. Magnetic noise characteristics of different amorphous and nanocrystalline materials used as the internal magnetic shielding layer of the magnetic shielding system were analyzed. In addition, the effects on magnetic noise due to adding aluminum to amorphous and nanocrystalline materials were studied. The experimental results show that compared with an amorphous material, a nanocrystalline material as the inner magnetic shield layer can effectively reduce the magnetic noise and improve the sensitivity and precision of the rotation measurement. Nanocrystalline material is very promising for inner shield composition in SERF co-magnetometers. Furthermore, its ultra-thin structure and low cost have significant application value in the miniaturization of SERF co-magnetometers.

4 September 2024 in Photonics
Verified
Journal Article
Open access
PDF file
KZKai Zhang
Kai Zhang
LYLinlin Yuan
Linlin Yuan
ZCZe Cai
Ze Cai
HGHang Gao
Hang Gao
RWRui Wang
Rui Wang
ZXZhou Xinxiu
Zhou Xinxiu
This paper systematically studies the output noise model of the K-Rb-21Ne co-magnetometer and proposes the method for determining the optimal pump laser power density. The amplitude-frequency response and the equivalent model for each frequency band are obtained through the transfer function of the co-magnetometer. Based on the established model and considering the power spectral density characteristics of magnetic noise, the output noise equation is formulated. Consequently, the pump laser power density yielding minimal output noise is determined. Both experimental and simulation results indicate that the pump laser power density yielding minimal output noise is greater than the pump laser power density corresponding to the maximum scale factor. Moreover, when the co-magnetometer operates at the pump laser power density corresponding to the minimal output noise, the output noise can be reduced by approximately 25%, and the Allan variance reaches its optimal value. The optimal Allan variance at 180 °C and 190 °C are 0.01395°/h @100 s and 0.01329°/h @100 s, respectively. Therefore, this pump laser power density is designated as the optimal pump laser power density for the co-magnetometer. Finally, simulations are conducted to investigate the variation patterns of the optimal pump laser power density points and the minimum output noise under different density ratios and gas pressures. The theories and methods proposed in this paper provide significant reference value for selecting the optimal pump laser power density and suppressing magnetic noise in co-magnetometers.

6 November 2025 in Measurement Science and Technology
Verified
Journal Article
Closed access
HGHang Gao
Hang Gao
WFWenfeng Fan
Wenfeng Fan
JHJiong Huang
Jiong Huang
HPHaoying Pang
Haoying Pang
WQWei Quan
Wei Quan
Spin-exchange relaxation-free atomic comagnetometer require a combined low-noise magnetic shielding system to provide a weak magnetic field environment. However, the remanent magnetization of the shielding materials themselves reduces the shielding performance, which necessitates suppression. This study addresses the demagnetization problem in magnetic shielding systems composed of µ -metal and MnZn ferrite by proposing a method based on optimizing the demagnetization function and minimizing the gaps between ferrite ring stacks to reduce the comagnetometer’s remanent magnetization. Experimental results demonstrate that the design achieves a magnetic field gradient of 0.94 nT cm −1 within ±3 cm of the shielding cylinder’s axial range, with a minimum value of 0.28 nT at the center. This performance significantly surpasses previously published results. Additionally, the long-term drift of the in situ magnetic field decreases with reduced remanent magnetization. The reduction in the shielding cylinder’s internal inhomogeneous magnetic field also suppresses atomic relaxation, thereby decreasing magnetic noise in the comagnetometer. This leads to a 14% reduction in rotation measurement sensitivity at 1 Hz. This study helps ferrite ring stacks approach the remanent magnetization levels of monolithic ferrite designs, making combined low-noise magnetic shielding systems more applicable to high-precision quantum measurement fields, especially those requiring large ferrite components.

20 January 2026 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
HGHang Gao
Hang Gao
ZCZe Cai
Ze Cai
WFWenfeng Fan
Wenfeng Fan
KZKai Zhang
Kai Zhang
XLXiaoping Li
Xiaoping Li
WQWei Quan
Wei Quan
Rotation sensing is essential for both fundamental physics and inertial navigation. The atomic spin comagnetometer is a promising candidate for high-precision gyroscopes, owing to its exceptional sensitivity. A key challenge lies in the coupling between magnetic field and rotation inputs, which degrades rotation measurement precision and affects the bias stability of the gyroscope. This study reports the first shipborne demonstration of a dual-axis comagnetometer for rotation sensing, confirming its viability for marine environments. By applying a rotating magnetic field orthogonal to the pump beam, a four-channel system is constructed to simultaneously sense dual-axis magnetic field and rotation. A linearized input–output model supports real-time, decoupled estimation of both inputs. Sea trials confirm that the comagnetometer can reliably monitor the pitch and yaw angular velocities of the vessel over extended durations. The time-domain outputs show good agreement with those from fiber-optic gyroscopes, demonstrating high accuracy and dynamic tracking performance. This study represents a significant step toward transforming atomic spin comagnetometers into practical, high-precision inertial sensors for real-world marine navigation.

14 September 2026 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
XLXiaoping Li
Xiaoping Li
WFWenfeng Fan
Wenfeng Fan
HGHang Gao
Hang Gao
SFShimiao Fan
Shimiao Fan
QYQi Yuan
Qi Yuan
WQWei Quan
Wei Quan
The magnetic dynamics at the nanoscale interface of amorphous insulators sit at the intersection of advancing ultrasensitive quantum sensing and understanding condensed matter physics. While noble-gas spin relaxation offers a powerful approach to probe these interfaces, it has long been restricted to probing bulk paramagnetic backgrounds due to the deep penetration depths of traditional dipolar probes. In this Letter, we report the observation of nanotesla-level magnetic hysteresis and thermally activated relaxation growth in aluminosilicate glass cells using $^{21}\mathrm{Ne}$ as a quadrupolar-enhanced quantum probe. The strong coupling between the nuclear electric quadrupole moment and the surface electric field gradient compresses the effective spin sampling depth to the nanometer scale [$\ensuremath{\sim}\mathcal{O}(1)\text{ }\text{ }\mathrm{nm}$]. By coupling Jiles-Atherton hysteresis dynamics with Cates diffusion and accounting for gas-phase thermal line broadening, we obtain a cross-cell average apparent activation energy of $⟨{E}_{\mathrm{act}}⟩\ensuremath{\approx}49.7\text{ }\text{ }\mathrm{kJ}/\mathrm{mol}$ within the present relaxation model. The pronounced field-history dependence of the relaxation is consistent with localized magnetic inhomogeneity at the glass interface. The proposed methodology provides an in situ, nondestructive, depth-selective probe of magnetic behavior at otherwise inaccessible amorphous glass interfaces, with potential utility for identifying wall-related relaxation in ultrasensitive comagnetometers.

28 October 2024 in Optics Letters
Verified
Journal Article
Closed access
HGHang Gao
Hang Gao
LDLihong Duan
Lihong Duan
WFWenfeng Fan
Wenfeng Fan
LYLinlin Yuan
Linlin Yuan
JHJiong Huang
Jiong Huang
WQWei Quan
Wei Quan
The longitudinal relaxation time (T1) of noble gas nuclear spins is a critical parameter for evaluating the performance of an atomic comagnetometer, significantly influencing the signal-to-noise ratio of the system. Traditional measurement techniques, such as the free induction decay method combined with the spin growth technique (FIDSG), are time-consuming for gases with extended T1 durations, such as 21Ne, and are prone to substantial environmental variability. Here, we propose the transverse low-frequency square-wave magnetic field modulation (LSMM) method for the rapid measurement of T1. The experiment indicates that the LSMM significantly condenses the measurement time to 19.2% of the original, thereby diminishing the robustness demands of the system. Although a minor discrepancy of up to 3 min (or 1.3%) exists between LSMM and FIDSG results, the LSMM method provides strong support for calibrating the performance of comagnetometer cells and conducting various nuclear spin polarization experiments, thereby improving efficiency and reducing energy loss.