Susanne Eich

Mrs. Susanne Eich


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 May 2013 in Sensors
Verified
Journal Article
Open access
PDF file
SESusanne Eich
Susanne Eich
ESElmar Schmälzlin
Elmar Schmälzlin
HLHans-Gerd Löhmannsröben
Hans-Gerd Löhmannsröben
In many biological and environmental applications spatially resolved sensing of molecular oxygen is desirable. A powerful tool for distributed measurements is optical time domain reflectometry (OTDR) which is often used in the field of telecommunications. We combine this technique with a novel optical oxygen sensor dye, triangular-[4] phenylene (TP), immobilized in a polymer matrix. The TP luminescence decay time is 86 ns. The short decay time of the sensor dye is suitable to achieve a spatial resolution of some meters. In this paper we present the development and characterization of a reflectometer in the UV range of the electromagnetic spectrum as well as optical oxygen sensing with different fiber arrangements.

30 April 2010
Verified
Conference Paper
Closed access
SESusanne Eich
Susanne Eich
ESElmar Schmälzlin
Elmar Schmälzlin
HLHans-Gerd Löhmannsröben
Hans-Gerd Löhmannsröben
Spatially resolved sensing of molecular oxygen is important for many biological and environmental applications. For this purpose, time-resolved fluorescence measurements were combined with optical time domain reflectometry (OTDR), a technique which was primarily developed for inspections of optical fiber lines. To achieve spatial resolution of some meters, which are typical for commercial OTDR instruments, the lifetimes of the sensor dyes must be within the range of some nanoseconds, which is much shorter than the decay times of common phosphorescent oxygen probes. Therefore, the measurements were performed with a novel fluorescent triangular-[4]phenylene sensor dye. The fluorescence decay times are around 80 ns in absence of oxygen and around 20 ns in the presence of air. The [4]phenylene sensor dye was applied in toluene solution as well as immobilized in a polymer film. Using a branched model fiber line, oxygen measurements were carried out in a micro- to millimolar concentration range. Oxygen-dependent fluorescence decay times measured with OTDR in toluene were verified by use of time-correlated single photon counting (TCSPC). The Stern-Volmer plots obtained for fluorescence quenching of sensor dyes dissolved in toluene solution and polymer-based sensor spots show good linearity.