Elmar Schmälzlin

Elmar Schmälzlin

Auto-generated profile, based on publicly available information

Elmar Schmälzlin

NanoPolyPhotonik, Fraunhofer Institute for Applied Polymer Research, Geiselbergstr. 69, 14476 Potsdam-Golm, Germany

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 May 2012 in Sensors
Verified
Journal Article
Open access
PDF file
CACindy Ast
Cindy Ast
ESElmar Schmälzlin
Elmar Schmälzlin
HLHans-Gerd Löhmannsröben
Hans-Gerd Löhmannsröben
JDJoost Van Dongen
Joost Van Dongen
Pioneered by Clark’s microelectrode more than half a century ago, there has been substantial interest in developing new, miniaturized optical methods to detect molecular oxygen inside cells. While extensively used for animal tissue measurements, applications of intracellular optical oxygen biosensors are still scarce in plant science. A critical aspect is the strong autofluorescence of the green plant tissue that interferes with optical signals of commonly used oxygen probes. A recently developed dual-frequency phase modulation technique can overcome this limitation, offering new perspectives for plant research. This review gives an overview on the latest optical sensing techniques and methods based on phosphorescence quenching in diverse tissues and discusses the potential pitfalls for applications in plants. The most promising oxygen sensitive probes are reviewed plus different oxygen sensing structures ranging from micro-optodes to soluble nanoparticles. Moreover, the applicability of using heterologously expressed oxygen binding proteins and fluorescent proteins to determine changes in the cellular oxygen concentration are discussed as potential non-invasive cellular oxygen reporters.

30 April 2010
Verified
Conference Paper
Closed access
SESusanne Eich
Susanne Eich
ESElmar Schmälzlin
Elmar Schmälzlin
HLHans-Gerd Löhmannsröben
Hans-Gerd Löhmannsröben
Spatially resolved sensing of molecular oxygen is important for many biological and environmental applications. For this purpose, time-resolved fluorescence measurements were combined with optical time domain reflectometry (OTDR), a technique which was primarily developed for inspections of optical fiber lines. To achieve spatial resolution of some meters, which are typical for commercial OTDR instruments, the lifetimes of the sensor dyes must be within the range of some nanoseconds, which is much shorter than the decay times of common phosphorescent oxygen probes. Therefore, the measurements were performed with a novel fluorescent triangular-[4]phenylene sensor dye. The fluorescence decay times are around 80 ns in absence of oxygen and around 20 ns in the presence of air. The [4]phenylene sensor dye was applied in toluene solution as well as immobilized in a polymer film. Using a branched model fiber line, oxygen measurements were carried out in a micro- to millimolar concentration range. Oxygen-dependent fluorescence decay times measured with OTDR in toluene were verified by use of time-correlated single photon counting (TCSPC). The Stern-Volmer plots obtained for fluorescence quenching of sensor dyes dissolved in toluene solution and polymer-based sensor spots show good linearity.