Stefan Popa

Mr. Stefan Popa

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2024 in High Power Laser Science and Engineering
Verified
Journal Article
Open access
PDF file
OCOlivier Chalus
Olivier Chalus
CDChristophe Derycke
Christophe Derycke
MCMathilde Charbonneau
Mathilde Charbonneau
SPStanislas Pasternak
Stanislas Pasternak
SRSandrine Ricaud
Sandrine Ricaud
IDIoan Dancus
Ioan Dancus
We are showing a significant enhancement in the temporal contrast by reducing the coherent noise of the 10 PW laser system at the Extreme Light Infrastructure - Nuclear Physics facility. The temporal contrast was improved by four orders of magnitude at 10 picoseconds and by more than one order of magnitude at 50 picoseconds before the main peak. This improvement of the picosecond contrast is critical for the experiments using thin solid targets.

15 November 2024 in High Power Laser Science and Engineering
Verified
Journal Article
Open access
PDF file
ANAndrei B. Nazîru
Andrei B. Nazîru
SPStefan Popa
Stefan Popa
ALAna-Maria Lupu
Ana-Maria Lupu
DMDan Gh, Matei
Dan Gh, Matei
ADAlice Dumitru
Alice Dumitru
DUDaniel Ursescu
Daniel Ursescu
Simultaneous ultra-intense pulses at petawatt laser facilities enable a broad range of experiments in nuclear photonics and strong field quantum electrodynamics. These experiments often require very precise control of the time delays between pulses. We report measurements of the time delay between the two 1 PW outputs of the Extreme Light Infrastructure - Nuclear Physics (ELI-NP) facility in Romania. The short-term standard deviation of the time delay was approximately half of the pulse duration of 23 fs, and the average delay drifted with up to 100 fs/h. The drift and sporadic delay jumps were corrected using a feedback loop, which reduced the long-term standard deviation of the delay close to its short-term value. These results imply that in ELI-NP experiments using two simultaneous pulses, a temporal overlap of better than half of the pulse duration can be achieved for more than two thirds of the shots, which would enable high data rate experiments using simultaneous petawatt pulses.

1 March 2026 in Plasma Physics and Controlled Fusion
Verified
Journal Article
Open access
LCL Calvin
L Calvin
EGE Gerstmayr
E Gerstmayr
CAC Arran
C Arran
LTL Tudor
L Tudor
TFT Foster
T Foster
Gianluca SarriGianluca Sarri
Gianluca Sarri
We report on experimental evidence of the generation of directional muons from a laser-wakefield accelerator driven by a PW-class laser. The muons were generated following the interaction of a GeV-scale high-charge electron beam with a 2 cm-thick Pb target and were detected using a Timepix3 detector placed behind a suitable shielding configuration. Data analysis indicates a ( 99.1 ± 0.5 ) % confidence of muon detection over noise, in excellent agreement with numerical modelling. Extrapolation of the experimental setup to higher electron energies and charges suggests the potential to guide and separate from noise approximately 10 4 muons s −1 onto cm 2 -scale areas for applications using a 10 Hz PW laser. These results demonstrate the possibility of generating and transporting directional muon beams using high-power lasers and establish a foundation for the systematic application of laser-driven high-energy muon beams.

24 May 2025 in Photonics
Verified
Journal Article
Open access
PDF file
SPStefan Popa
Stefan Popa
ANAndrei Nazîru
Andrei Nazîru
ALAna-Maria Lupu
Ana-Maria Lupu
DMDan Gh, Matei
Dan Gh, Matei
Alice Diana DumitruAlice Diana Dumitru
Alice Diana Dumitru
DUDaniel Ursescu
Daniel Ursescu
High-repetition-rate targets present an opportunity for developing diagnostic tools for on-demand calibration at high-power laser facilities for consistent performance and reproducibility during experimental campaigns. The non-linear change in transmission associated with a laser-driven plasma mirror, based on high-repetition rate targets, has been used in a Frequency Resolved Optical Gating (FROG) configuration to analyze the spectral phase for near-infrared pulses far from the Fourier limit. Three types of targets were compared for characterizing pulses in the 1–8 ps range: a glass slide, a polymer tape, and a thin liquid sheet created by two impinging micrometer-scale jets. The thin liquid film had the best mechanical stability and introduced the least spectral distortion, allowing the most robust reconstruction of the temporal intensity profile. The spectral phase was reconstructed using a non-iterative algorithm, which reproduced the second-order phase distortions induced with an acousto-optic programmable dispersive filter with an RMS error of 6.2%, leading to measured pulse durations with an RMS deviation ranging from 1% for pulses of 6.8–7.8 ps up to 7.5% for pulses around 1 ps.

25 March 2026 in High Power Laser Science and Engineering
Verified
Journal Article
Open access
PDF file
SIStefania Cristina Ionescu
Stefania Cristina Ionescu
VPVanessa Ling Jen Phung
Vanessa Ling Jen Phung
CGCristina Constanta Gheorghiu
Cristina Constanta Gheorghiu
MEMichael Ehret
Michael Ehret
NGNina Gamaiunova
Nina Gamaiunova
VLVictor Leca
Victor Leca
We review prevalent fabrication techniques for targets used in high-power and high-intensity single-beam laser experiments, emphasizing their applications and performance. Solid targets include free-standing metallic and carbon films of various thicknesses for particle acceleration studies involving proton and carbon beams and micro-/nano-structured surfaces, as well as near-critical-density materials, such as foams, which enhance laser absorption and coupling, and boron targets for proton–boron fusion experiments. The resulting gamma and proton beams enable applications in isomer production, proton therapy, societal applications and fundamental studies. The use of gas targets for electron acceleration via the laser wakefield acceleration mechanism is discussed, as are cryogenic clusters undergoing Coulomb explosion. Finally, liquid, cryogenic and tape target systems are presented as high-repetition-rate and application-oriented solutions, offering high reproducibility and long-term operation.

1 October 2026 in Physics of Plasmas
Verified
Journal Article
Closed access
DBDimiter L. Balabanski
Dimiter L. Balabanski
ACA. S. Cucoaneș
A. S. Cucoaneș
VHVojtech Horny
Vojtech Horny
JOJian Fuh Ong
Jian Fuh Ong
SPStefan Popa
Stefan Popa
DUDaniel Ursescu
Daniel Ursescu
High-power laser systems have the potential to provide a compact and decentralized complementary technology to conventional cyclotrons for the production of medical radioisotopes. Within the Dr. Laser project at Extreme Light Infrastructure - Nuclear Physics, we focus on the production of 11C, a key positron-emitting radionuclide that can be incorporated into a wide range of molecules without altering their biological functionality. This work presents a comprehensive simulation framework for optimizing the entire laser-driven radioisotope production chain. The framework integrates hydrodynamic and particle-in-cell simulations for secondary ion generation from sub-micron liquid targets, as well as nuclear activation calculations for natural and enriched boron. The article also discusses optical techniques for beam focusing and the 11C extraction from target materials, such as boron nitride, boron oxide, and sodium borohydride. The simulation results indicate that current 100-TW-class, 10-Hz laser systems can achieve end-of-irradiation activities of 50–100 MBq. After processing, these activities are expected around 10–20 MBq, which is sufficient for preclinical research studies. Our simulations also show that a system based on 100 TW laser and sub-micron liquid-sheet targets is able to provide stable Target Normal Sheath Acceleration conditions, well suited for efficient laser-driven 11C production.