Purpose. This study aimed to develop a new method for automated contrast-to-noise ratio (CNR) measurement using the low-contrast object in the ACR computed tomography (CT) phantom. Methods. The proposed method for CNR measurement was based on statistical criteria. A region of interest (ROI) was placed in a specific radial location and was then rotated around 360° in increments of 2°. At each position, the average CT number within the ROI was calculated. After one complete rotation, a profile of the average CT number around the full rotation was obtained. The center coordinate of the low-contrast object was determined from the maximum value of the profile. The CNR was calculated based on the average CT number and noise within the ROI in the low-contrast object and the ROI in the background, i.e., at the center of the phantom. The proposed method was used to evaluate CNR from images scanned with various phantom rotations, images with various noise levels (tube currents), and images from 25 CT scanners. The results were compared to a previous method based on a threshold approach. Results. The proposed method successfully placed the ROI properly in the center of a low-contrast object for variations of phantom rotation and tube current, whereas was not properly located in the center of the low-contrast object using the previous method. In addition, from 325 image samples of the 25 CT scanners, the proposed method successfully (100%) located the ROI within the low-contrast objects of all images used. The success rate of the previous method was only 58%. Conclusion. A new method for measuring CNR in the ACR CT phantom has been proposed and implemented. It is more powerful than a previous method based on a threshold approach.
This study aims to develop and validate software for the automatic measurement of the task-transfer function (TTF) based on the American Association of Physicists in Medicine (AAPM) Task Group (TG) 233. The software consists of two main stages: automatic placement of the region of interest (ROI) within circular objects of the phantoms and calculating the TTF. The software was developed on four CT phantom types: computational phantom, ACR 464 CT phantom, AAPM CT phantom, and Catphan® 604 phantom. Each phantom was tested with varying parameters, including spatial resolution level, slice thickness, and image reconstruction technique. The results of TTF were compared with manual measurements performed using ImQuest version 7.3.01 and iQmetix-CT version v1.2. The software successfully located ROIs at all circular objects within each phantom and measured accurate TTF with various contrast-to-noise ratios (CNRs) of all phantoms. The TTF results were comparable to those obtained with ImQuest and iQmetrix-CT. It was found that the TTF curves produced by the software are smoother than those produced by ImQuest. An algorithm for the automated measurement of TTF was successfully developed and validated. TTF measurement with our software is highly user-friendly, requiring only a single click from the user.
This study evaluates the performance of a statistical-based automatic contrast-to-noise ratio (CNR) measurement method on images of the ACR CT phantom under varying imaging parameters. A statistical automatic method for segmenting low-contrast objects and for measuring CNR was recently introduced. The method employs a 25 mm region of interest (ROI), rotated in 2° clockwise steps, to identify the low-contrast object by locating the maximum CT value. The CNR was measured on images acquired with different parameters: tube voltage (80–140 kVp), tube current (80–200 mA), slice thickness (1.25–10 mm), field of view (190–230 mm), and convolution kernel (edge, ultra, lung, bone, chest, standard). The automatic results were compared to manual measurements. The automatic method accurately identified the largest low-contrast object. The CNR values from the automatic and manual methods showed no significant difference (p > 0.05). The CNR increased with higher tube voltage and current, and with thinner slice thickness. Chest and standard kernels yielded higher CNRs, while edge, ultra, lung, and bone kernels yielded lower ones. The CNR remained stable with minor FOV changes. The statistical-based automatic method provided accurate and consistent CNR measurements across a range of imaging settings for the ACR CT phantom.
The purpose of this study to develop software to extract and investigate the rofiles of the tube current and volume computed tomography dose index (CTDIvol) along the longitudinal axis (z-axis). The tube current and CTDIvol were extracted from the Digital Imaging and Communications in Medicine (DICOM) header of every image along the longitudinal axis. We evaluated the profiles of the tube current and CTDIvol from eight computed tomography (CT) scanners. If the CTDIvol did not fluctuate along the fluctuation of the tube currents, then the system will adjust the CTDIvol with tube currents. It is found that TCM is not always activated. If TCM is activated, the profiles of TCM vary from one scanner to another. The Siemens and Philip scanners have adjusted the CTDIvol profile with tube current, but the Toshiba scanner has not. By developed software, CTDIvol profile of the Toshiba can be easily adjusted. In conclusion, software to investigate the profile pattern of CTDIvol along the longitudinal axis has been successfully developed. The software is easy to use and works quickly. From this study, medical staff must be careful when using the CTDIvol along longitudinal axis contained in each DICOM header.