Ariij Naufal

Mr. Ariij Naufal

Department of Physics, Diponegoro University, Semarang, Jawa Tengah, Indonesia
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 October 2022 in Algorithms
Verified
Journal Article
Open access
PDF file
Choirul AnamChoirul Anam
Choirul Anam
ANAriij Naufal
Ariij Naufal
HSHeri Sutanto
Heri Sutanto
KAKusworo Adi
Kusworo Adi
Geoff DoughertyGeoff Dougherty
Geoff Dougherty
A bilateral filter is a non-linear denoising algorithm that can reduce noise while preserving the edges. This study explores the characteristics of a bilateral filter in changing the noise and texture within computed tomography (CT) images in an iterative implementation. We collected images of a homogeneous Neusoft phantom scanned with tube currents of 77, 154, and 231 mAs. The images for each tube current were filtered five times with a configuration of sigma space (σd) = 2 pixels, sigma intensity (σr) = noise level, and a kernel of 5 × 5 pixels. To observe the noise texture in each filter iteration, the noise power spectrum (NPS) was obtained for the five slices of each dataset and averaged to generate a stable curve. The modulation-transfer function (MTF) was also measured from the original and the filtered images. Tests on an anthropomorphic phantom image were carried out to observe their impact on clinical scenarios. Noise measurements and visual observations of edge sharpness were performed on this image. Our results showed that the bilateral filter was effective in suppressing noise at high frequencies, which is confirmed by the sloping NPS curve for different tube currents. The peak frequency was shifted from about 0.2 to about 0.1 mm−1 for all tube currents, and the noise magnitude was reduced by more than 50% compared to the original images. The spatial resolution does not change with the number of iterations of the filter, which is confirmed by the constant values of MTF50 and MTF10. The test results on the anthropomorphic phantom image show a similar pattern, with noise reduced by up to 60% and object edges remaining sharp.

16 December 2022 in Biomedical Physics & Engineering Express
Verified
Journal Article
Closed access
Choirul AnamChoirul Anam
Choirul Anam
RARiska Amilia
Riska Amilia
ANAriij Naufal
Ariij Naufal
WBWahyu S Budi
Wahyu S Budi
AMAnisa T Maya
Anisa T Maya
GDGeoff Dougherty
Geoff Dougherty
We developed a software to automatically measure the linearity between the CT numbers and densities of objects using an ACR 464 CT phantom, and investigated the CT number linearity of 16 different CT scanners. The software included a segmentation-rotation method. After segmenting five objects within the phantom image, the software computed the mean CT number of each object and plotted a graph between the CT numbers and densities of the objects. Linear regression and coefficients of regression, R2, were automatically calculated. The software was used to investigate the CT number linearity of 16 CT scanners from Toshiba, Siemens, Hitachi, and GE installed at 16 hospitals in Indonesia. The linearity of the CT number obtained on most of the scanners showed a strong linear correlation (R 2 > 0.99) between the CT numbers and densities of the five phantom materials. Two scanners (Siemens Emotion 16) had the strongest linear correlation with R 2 = 0.999, and two Hitachi Eclos scanners had the weakest linear correlation with R 2 < 0.99.

20 November 2024 in Biomedical Physics & Engineering Express
Verified
Journal Article
Closed access
Choirul AnamChoirul Anam
Choirul Anam
RARiska Amilia
Riska Amilia
ANAriij Naufal
Ariij Naufal
TFToshioh Fujibuchi
Toshioh Fujibuchi
GDGeoff Dougherty
Geoff Dougherty
Purpose. This study aimed to develop a new method for automated contrast-to-noise ratio (CNR) measurement using the low-contrast object in the ACR computed tomography (CT) phantom. Methods. The proposed method for CNR measurement was based on statistical criteria. A region of interest (ROI) was placed in a specific radial location and was then rotated around 360° in increments of 2°. At each position, the average CT number within the ROI was calculated. After one complete rotation, a profile of the average CT number around the full rotation was obtained. The center coordinate of the low-contrast object was determined from the maximum value of the profile. The CNR was calculated based on the average CT number and noise within the ROI in the low-contrast object and the ROI in the background, i.e., at the center of the phantom. The proposed method was used to evaluate CNR from images scanned with various phantom rotations, images with various noise levels (tube currents), and images from 25 CT scanners. The results were compared to a previous method based on a threshold approach. Results. The proposed method successfully placed the ROI properly in the center of a low-contrast object for variations of phantom rotation and tube current, whereas was not properly located in the center of the low-contrast object using the previous method. In addition, from 325 image samples of the 25 CT scanners, the proposed method successfully (100%) located the ROI within the low-contrast objects of all images used. The success rate of the previous method was only 58%. Conclusion. A new method for measuring CNR in the ACR CT phantom has been proposed and implemented. It is more powerful than a previous method based on a threshold approach.


5 October 2025 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
Choirul AnamChoirul Anam
Choirul Anam
ANAriij Naufal
Ariij Naufal
HSHeri Sutanto
Heri Sutanto
KAKusworo Adi
Kusworo Adi
CYChai Hong Yeong
Chai Hong Yeong
GDGeoff Dougherty
Geoff Dougherty
Objective. The aim of this study was to develop an automatic method for generating a detectability index (d′)-based contrast–detail (C–D) curve across multiple object sizes and contrasts, and to evaluate its performance under varying tube current settings and reconstruction filter types. Approach. To compute d′ for a given object size and contrast, the task-transfer function and noise power spectrum were obtained from ACR 464 computed tomography (CT) phantom images acquired at tube currents of 80, 120, 160 and 200 mA, using Edge, Lung, and Soft filter types. The task objects were varied in size (1–15 mm) and contrast levels (1–15 HU) with both flat and Gaussian signal types. For each defined task object, d′ was calculated using a non-prewhitening model observer. This process was iterated for every predefined task function across multiple object sizes and contrasts, resulting in a d′ map corresponding to the synthetic low-contrast images. A C–D curve was then generated using a d′ cut-off value defined by the user. For comparison, a separate C–D curve was generated based on visual assessment by five human observers (HOs). Main results. The automated method successfully computed d′ values and arranged synthetic low-contrast images into a grid according to object size and contrast. C–D curves using d′ cut-off values of 3 or 4 most closely reflected HOs performance. For tube current variations, increasing the current led to higher detectability. For filter type variations, the Lung filter resulted in relatively lower detectability compared to the Edge and Soft filters. Significance. An automated method to calculate d′ across a wide range of object sizes and contrasts, and to generate a d′-based C–D curve for CT protocol optimization was developed. The results were consistent with HO trends and effectively captured detectability changes across different imaging parameters.

30 May 2023 in Biomedical Physics & Engineering Express
Verified
Journal Article
Closed access
Choirul AnamChoirul Anam
Choirul Anam
ANAriij Naufal
Ariij Naufal
HSHeri Sutanto
Heri Sutanto
ZAZaenal Arifin
Zaenal Arifin
EHEko Hidayanto
Eko Hidayanto
GDGeoff Dougherty
Geoff Dougherty
Objective. To develop an algorithm to measure slice thickness running on three types of Catphan phantoms with the ability to adapt to any misalignment and rotation of the phantoms. Method. Images of Catphan 500, 504, and 604 phantoms were examined. In addition, images with various slice thicknesses ranging from 1.5 to 10.0 mm, distance to the iso-center and phantom rotations were also examined. The automatic slice thickness algorithm was carried out by processing only objects within a circle having a diameter of half the diameter of the phantom. A segmentation was performed within an inner circle with dynamic thresholds to produce binary images with wire and bead objects within it. Region properties were used to distinguish wire ramps and bead objects. At each identified wire ramp, the angle was detected using the Hough transform. Profile lines were then placed on each ramp based on the centroid coordinates and detected angles, and the full-width at half maximum (FWHM) was determined for the average profile. The slice thickness was obtained by multiplying the FWHM by the tangent of the ramp angle (23°). Results. Automatic measurements work well and have only a small difference (<0.5 mm) from manual measurements. For slice thickness variation, automatic measurement successfully performs segmentation and correctly locates the profile line on all wire ramps. The results show measured slice thicknesses that are close (<3 mm) to the nominal thickness at thin slices, but slightly deviated for thicker slices. There is a strong correlation (R2 = 0.873) between automatic and manual measurements. Testing the algorithm at various distances from the iso-center and phantom rotation angle also produced accurate results. Conclusion. An automated algorithm for measuring slice thickness on three types of Catphan CT phantom images has been developed. The algorithm works well on various thicknesses, distances from the iso-center, and phantom rotations.