The aim of this study was to evaluate the effectiveness of the novel aerobic granular sludge (AGS) wastewater treatment technology in removing faecal indicator organisms (FIOs) compared to the conventional activated sludge (CAS) treatment system. The work was carried out at two full-scale wastewater treatment plants (WWTP) in the Netherlands, Vroomshoop and Garmerwolde. Both treatment plants have a CAS and AGS system operated in parallel. The parallel treatment lines are provided with the same influent wastewater. The concentrations of the measured FIOs in the influent of the two WWTPs were comparable with reported literature values as follows: F-specific RNA bacteriophages at 106 PFU/100 mL, and Escherichia coli (E. coli), Enterococci, and Thermotolerant coliforms (TtC) at 105 to 106 CFU/100 mL. Although both systems (CAS and AGS) are different in terms of design, operation, and microbial community, both systems showed similar FIOs removal efficiency. At the Vroomshoop WWTP, Log10 removals for F-specific RNA bacteriophages of 1.4 ± 0.5 and 1.3 ± 0.6 were obtained for the AGS and CAS systems, while at the Garmerwolde WWTP, Log10 removals for F-specific RNA bacteriophages of 1.9 ± 0.7 and 2.1 ± 0.7 were found for the AGS and CAS systems. Correspondingly, E. coli, Enterococci, and TtC Log10 removals of 1.7 ± 0.7 and 1.1 ± 0.7 were achieved for the AGS and CAS systems at Vroomshoop WWTP. For Garmerwolde WWTP Log10 removals of 2.3 ± 0.8 and 1.9 ± 0.7 for the AGS and CAS systems were found, respectively. The measured difference in removal rates between the plants was not significant. Physicochemical water quality parameters, such as the concentrations of organic matter, nutrients, and total suspended solids (TSS) were also determined. Overall, it was not possible to establish a direct correlation between the physicochemical parameters and the removal of FIOs for any of the treatment systems (CAS and AGS). Only the removal of TSS could be positively correlated to the E. coli removal for the AGS technology at the evaluated WWTPs.
1 November 2020 in Science of The Total Environment
The co-treatment of two synthetic faecal sludges (FS-1 and FS-2) with municipal synthetic wastewater (WW) was evaluated in an aerobic granular sludge (AGS) reactor. After characterisation, FS-1 showed the following concentrations, representative for medium-strength FS: 12,180 mg TSS L-1, 24,300 mg total COD L-1, 93.8 mg PO3-P L-1, and 325 mg NH4-N L-1. The NO3-N concentration was relatively high (300 mg L-1). For FS-2, the main difference with FS-1 was a lower nitrate concentration (18 mg L-1). The recipes were added consecutively, together with the WW, to an AGS reactor. In the case of FS-1, the system was fed with 7.2 kg total COD m-3d-1 and 0.5 kg Nitrogen m-3d-1. Undesired denitrification occurred during feeding and settling resulting in floating sludge and wash-out. In the case of FS-2, the system was fed with 8.0 kg total COD m-3d-1 and 0.3 kg Nitrogen m-3d-1. The lower NO3-N concentration in FS-2 resulted in less floating sludge, a more stabilised granular bed and better effluent concentrations. To enhance the hydrolysis of the slowly biodegradable particulates from the synthetic FS, an anaerobic stand-by period was added and the aeration period was increased. Overall, when compared to a control AGS reactor, a lower COD consumption (from 87 to 35 mg g-1 VSS h-1), P-uptake rates (from 6.0 to 2.0 mg P g VSS-1 h-1) and NH4-N removal (from 2.5 to 1.4 mg NH4-N g VSS-1 h-1) were registered after introducing the synthetic FS. Approximately 40% of the granular bed became flocculent at the end of the study, and a reduction of the granular size accompanied by higher solids accumulation in the reactor was observed. A considerable protozoa Vorticella spp. bloom attached to the granules and the accumulated particles occurred; potentially contributing to the removal of the suspended solids which were part of the FS recipe.
The aerobic granular sludge (AGS) process is an effective wastewater treatment technology for organic matter and nutrient removal that has been introduced in the market rapidly. Until now, limited information is available on AGS regarding the removal of bacterial and viral pathogenic organisms present in sewage. This study focussed on determining the relation between reactor operational conditions (plug flow feeding, turbulent aeration and settling) and physical and biological mechanisms on removing two faecal surrogates, Escherichia coli and MS2 bacteriophages. Two AGS laboratory-scale systems were separately fed with influent spiked with 1.0 × 106 CFU/100 mL of E. coli and 1.3 × 108 PFU/100 mL of MS2 bacteriophages and followed during the different operational phases. The reactors contained only granular sludge and no flocculent sludge. Both systems showed reductions in the liquid phase of 0.3 Log10 during anaerobic feeding caused by a dilution factor and attachment of the organisms on the granules. Higher removal efficiencies were achieved during aeration, approximately 1 Log10 for E. coli and 0.6 Log10 for the MS2 bacteriophages caused mainly by predation. The 18S sequencing analysis revealed high operational taxonomic units (OTUs) of free-living protozoa genera Rhogostoma and Telotrochidium concerning the whole eukaryotic community. Attached ciliates propagated after the addition of the E. coli, an active contribution of the genera Epistylis, Vorticella, and Pseudovorticella was found when the reactor reached stability. In contrast, no significant growth of predators occurred when spiking the system with MS2 bacteriophages, indicating a low contribution of protozoa on the phage removal. Settling did not contribute to the removal of the studied bacterial and viral surrogates.
Wastewater treatment plants (WWTPs) are recognised as key hotspots for the dissemination of antimicrobial-resistant bacteria and antimicrobial resistance genes (ARGs). However, studies addressing the role of domestic WWTPs in the spread of resistance traits in tropical regions remain limited. This study evaluated a domestic WWTP during dry and rainy seasons to examine its role as a reservoir and dissemination hub for ARGs and potential bacterial pathogens. The WWTP demonstrated stable physicochemical removal efficiencies, although its performance slightly decreased during the rainy season. Notably, the relative abundance of ARGs measured by qPCR was higher in the effluent than in the influent of the WWTP. Metagenomic analysis of activated sludge revealed that chromosomally encoded ARGs conferred resistance to macrolides, aminoglycosides, rifamycin, sulphonamides, and tetracyclines. In contrast, plasmid-associated ARGs were primarily linked to resistance against quaternary ammonium compounds (QACs), indicating the presence of a potential conjugative plasmid facilitating the mobility and persistence of QAC resistance genes within the microbial community. Furthermore, pathobiome analysis identified a high relative abundance of potential pathogens, including genera Gordonia, Acidovorax, Pseudomonas, and Mycobacterium members. These findings highlight the role of domestic WWTPs as reservoirs and potential amplifiers of antimicrobial resistance in tropical environments.
[Objective] This study aimed to evaluate the short-term response of four different odor control measures in a homogenization tank of a university Wastewater Treatment Plant (WWTP). [Methodology] The following were implemented: aeration, adding lime, adding iron sulfate, and adding the commercial product BiOWiSH® Odor over four hydraulic retention times. The effluent and the unit were monitored during each period, using a baseline to compare the measures. Hydrogen potential, oxidation-reduction potential, dissolved oxygen, and dissolved sulfide concentration were measured in triplicate every 30 minutes. An odor perception survey was administered to WWTP visitors to evaluate intensity, offensiveness, and character (15 surveys per monitoring period). Differences were determined between control measures and the baseline using Student’s t-tests (quantitative data) and Mood’s median tests (qualitative data). Minitab 2019 was used with a 95% confidence level. [Results] All control measures significantly reduced the dissolved sulfide concentration in the unit. Aeration prevented oxygen depletion, reductive regime, and acid fermentation, which favored the oxidation of odorants. Aeration was also the only studied control measure that reduced odor intensity and offensiveness. [Conclusions] Applying aeration changed unit behavior and odor perception, which confirms its effectiveness, while adding iron sulfate, lime, and BiOWiSH® did not significantly change odor perception.
La gestión de aguas residuales en Costa Rica, centrada principalmente en la regulación de la eliminación de materia orgánica, requiere una inversión en tecnologías para abordar una mayor gama de contaminantes. Como institución académica, el TEC está promoviendo la tecnología de Lodos Aeróbicos Granulares, basada en aglomerados de bacterias que se forman de manera natural estimulando la actividad biológica desde el centro hacia el exterior del gránulo, asegurando así la remoción simultánea de materia orgánica, nitrógeno y fósforo. Este enfoque ha impulsado la creación de prototipos de sistemas adaptados a las necesidades de las comunidades costarricenses, utilizando modelos matemáticos que garantizan la eliminación completa de contaminantes. Además, se está avanzando a través de investigaciones de laboratorio y colaboración nacional e internacional para implementar esta tecnología en el contexto del país y promover su adopción a gran escala.