The influence of the interventional treatment approach for transarterial radioembolization (TARE) on the incidence of extrahepatic microsphere depositions and to angiographic complications was evaluated. In total, 398 TARE cycles were analyzed. Interventional treatment approaches were classified as single treatment position (TP) with interventional occlusion (IO), multiple TPs without IO, and multiple TPs with IO. Correlations with extrahepatic microsphere depositions, angiographic complications, and periprocedural clinical events were performed. Alternative treatment strategies were evaluated. Applications from multiple TPs could have ensured the safe application of microspheres in 48.2% of cases that were originally performed from a single TP after IO. Extrahepatic microsphere accumulations were detected after 5.2%, 5.3%, and 1.5% of TARE procedures from a single TP without IO, a single TP with IO, and multiple TPs without IO, respectively. Applications from multiple TPs did not increase angiographic complications. During the 30-day follow-up, nausea/vomiting and upper abdominal discomfort were observed more frequently in the group with IO than in the group without IO (7.9%/4.6% and 9.2%/5.9%, respectively). In many TARE procedures, the same target liver can be treated from multiple TPs instead of a single TP, reducing the need for the interventional occlusion of aberrant arteries and potential extrahepatic microsphere depositions.
The differentiation of splenic tissue from malignant lesions via imaging may be challenging, particularly considering aberrant or accessory lesions and diseases that are rarely encountered. Functioning splenic tissue can be identified using technetium-99m red blood cell (99mTc-RBC) scintigraphy, but its sensitivity is limited and may not be available. We present the case of a patient in whom disseminated abdomino-pelvic splenosis was diagnosed using PET/CT with gallium-68-oxine-labeled RBCs. The method represents a feasible and probably superior alternative to splenic scintigraphy.
Hepatobiliary scintigraphy is a well-established nuclear imaging method for evaluating liver function and displaying the biliary system, but the spatial and temporal resolution is limited, and, there is still no established PET equivalent. Adapted from the work of Schuhmacher et al. in 1983, the production of a 68Gallium-labeled substitute, tetrabromophthalein ([68Ga]Ga-BP-IDA), was undertaken according to current Good Manufacturing Practice (GMP) standards and proved feasible and reproducible. PET/CT with the radiotracer was performed in two complex patients with hepatocellular carcinoma in preparation for transarterial radioembolization. Due to its high spatial and temporal resolution, localization of areas with impaired liver function and visualization of the biliary system were possible. We could demonstrate that this 68Gallium-labeled, IDA-based PET tracer is feasible and could advance hepatic and biliary function PET imaging.
Background: In addition to clinical examinations, confirmatory investigations are frequently performed to determine brain death (BD). Among other perfusion tests, brain perfusion scintigraphy (BPS) has been shown to be a reliable tool for the detection of brain circulatory arrest, particularly in cases with inconclusive clinical status or potential pharmacological interactions. Methods: Evaluation for brain death included standardized clinical examinations by two experienced neuro-intensive medicine specialists, followed by ancillary brain perfusion tests. BPS with the lipophilic tracer 99mTc-hexamethylpropyleneamine oxime (HMPAO) was performed according to a standardized protocol. Imaging results, additional confirmatory test results, as well as clinical parameters were prospectively recorded. Results: BPS was performed in 30 patients (18 male, 12 female; median age 55.5 years, range 0.1–79.8 years). Eight patients underwent decompressive craniectomy (DC) prior to BD evaluation, three patients were supported by veno-arterial extracorporeal membrane oxygenation (vaECMO), and one patient by a left ventricular assist device (LVAD). The median interval between the initial brain-damaging event and BPS was 4.0 days (range 1–18 days). BPS demonstrated brain perfusion cessation in all patients. A concomitant single-photon emission computed tomography (SPECT) was required in one patient. There were no technical failures requiring a re-examination. Conclusions: BPS is a feasible, safe, and technically robust confirmatory test in BD diagnosis. BPS yielded unambiguous results, particularly in cases with inconclusive results of other ancillary tests, in neonates, young children and patients after DC. It is applicable to patients supported by LVAD and vaECMO.
Background/Objectives: Biliary complications are common after liver transplantation (LT), with bile leaks representing a major cause of morbidity. Conventional imaging modalities such as ultrasound, CT, MRCP, and endoscopic techniques may fail to localize peripheral or complex leaks. This study aimed to evaluate the feasibility of [68Ga]Ga-TEoS-DAZA-PET/CT for non-invasive localization of bile leaks after LT. Methods: Five male patients (mean age 53.2 years) with suspected bile leakage and inconclusive prior imaging underwent [68Ga]Ga-TEoS-DAZA-PET/CT. The tracer was synthesized under GMP conditions and administered at a mean activity of 204 ± 42 MBq. Dynamic PET/CT imaging was performed for 60 min, and findings were classified according to the Nagano classification. Results: Bile leaks were detected and anatomically localized in all five patients. Sites included the liver resection surface, central bile ducts, bilioenteric anastomosis, and biliary drainage exit. PET/CT findings guided revision surgery in one case and endoscopic treatment in three, while one patient improved without intervention. No adverse effects occurred. Conclusions: [68Ga]Ga-TEoS-DAZA-PET/CT is a feasible and safe imaging technique for the anatomical localization of bile leaks following LT. Its antegrade visualization of biliary flow, high spatial and temporal resolution, and lack of contraindications make it a promising complementary modality when conventional imaging is inconclusive or not feasible. Larger studies are warranted to validate its diagnostic value and clinical utility in postoperative and post-traumatic biliary injuries.
Background/Objectives: Lung cancer is one of the most prevalent malignant diseases in humans. Numerous studies have demonstrated the significance of [18F]fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) in the staging of this condition. Methods: The pictorial evaluation is based on a recent study comparing preoperative imaging with postoperative histopathological findings following thoracic surgery. It confirmed the value of PET/CT in assessing primary tumor extent and metastatic lymph node involvement; but also revealed discrepancies in primary tumor (T) and lymph nodes (N) classification in 25% and 14% of patients, respectively. Results: The aim of this pictorial review is to highlight and further analyze the causes of inaccurate staging, identify potential diagnostic pitfalls, and provide practical recommendations to help avoid misinterpretation of PET/CT findings. Additionally, the impact of the newly introduced ninth edition of the International Association for the Study of Lung Cancer (IASLC) primary tumor, lymph nodes, and metastasis (TNM) staging system for lung cancer is discussed. Conclusions: In this pictorial review, we presented various sources of error in preoperative staging observed at our institution. Awareness of these potential pitfalls may aid in improving staging accuracy and distinguishing physiological or reactive (benign) processes from pathological findings.