Qiao Wang

Dr. Qiao Wang

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 February 2020 in British Journal of Radiology
Verified
Journal Article
Closed access
CLChang Liu
Chang Liu
SDShi-Si Ding
Shi-Si Ding
KZKun Zhang
Kun Zhang
LLLinna Liu
Linna Liu
LGLe-Hang Guo
Le-Hang Guo
HXHuixiong Xu
Huixiong Xu
Objectives: The aim of this study was to develop an ultrasound consolidated score (UCS) in determining the activity of Crohn’s disease (CD) and evaluate it with reference to simple endoscopic score (SES). Methods: From June 2014 to June 2017, 66 patients with CD were retrospectively enrolled in this study. Each patient underwent endoscopy and transabdominal ultrasound (US) examination. The morphological symmetry, echogenicity of bowel wall, bowel wall layer structure, echogenicity of peri-bowel fat, bowel wall thickness (BWT), and Limberg type on power Doppler US were assessed with transabdominal US, and an UCS scoring system was developed based on these characteristics. Endoscopic results were used as the reference standard and SES was calculated to determine the CD activity. Receiver operating characteristic curve analysis was performed to assess the diagnostic performance for determining CD activity and the correlation between UCS and SES was assessed using Spearman correlation analysis. Results: 330 intestinal segments in 66 patients were included. The UCS of the segments in the remission phase ranged from 3.0 to 9.0 (mean, 3.6 ± 0.9) whereas in the active phase from 3.0 to 20.0 (mean, 10.6 ± 4.0) (p < 0.001). The cut-off value of UCS was 6. The associated area under ROC curve, sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 0.980, 88.3%, 95.5%, 93.8%, 91.3%, and 92.3%, respectively. The correlation coefficient between UCS and SES was 0.90, which was higher than the correlation coefficient of 0.83 between BWT and SES. Conclusions: The newly developed UCS with transabdominal US has a good performance and potentially provides an effective alternative for evaluating the activity of CD. Advances in knowledge: UCS is an effective method to evaluate the activity of CD because it provides comprehensive information of the disease. Therefore, it could be employed as an alternative for diagnosis of CD.

1 April 2022 in Ultrasonography
Verified
Journal Article
Open access
PDF file
YSYi-Kang Sun
Yi-Kang Sun
XLXiao-Long Li
Xiao-Long Li
QWQiao Wang
Qiao Wang
BZBo-Yang Zhou
Bo-Yang Zhou
AZAn-Qi Zhu
An-Qi Zhu
HXHuixiong Xu
Huixiong Xu
Purpose: This prospective study explored the value of synchronous tele-ultrasound (US) to aid doctors inexperienced in US with breast US examinations.Methods: In total, 99 patients were enrolled. Two trainee doctors who were inexperienced in US (trainee A [TA] and trainee B [TB]) and one doctor who was an expert in US completed the US examinations sequentially. TA completed the US examinations independently, while TB was instructed by the expert using synchronous tele-US. Subsequently, the expert performed on-site US examinations in person. Separately, they selected the most clinically significant nodule as the target nodule. Consistency with the expert and image quality were compared between TA and TB to evaluate tele-US. Furthermore, TB and the patients evaluated tele-US through questionnaires.Results: TB demonstrated higher consistency with the expert in terms of target nodule selection than TA (93.3% vs. 63.3%, P0.75) with the expert on five US features (5/9, 55.6%), while TA only did so for one (1/9, 11.1%) (P=0.046). TB’s image quality was higher than TA’s in gray value, time gain compensation, depth, color Doppler adjustment, and the visibility of key information (P=0.018, P<0.001, P<0.001, P=0.033, and P=0.006, respectively). The comprehensive assessment score was higher for TB than for TA (3.96±0.82 vs. 3.09±0.87, P<0.001). Tele-US was helpful in 69.7% of US examinations and had a training effect in 68.0%. Furthermore, 63.6% of patients accepted tele-US and 60.6% were willing to pay.Conclusion: Tele-US can help doctors inexperienced in US to perform breast US examinations.

1 July 2024 in Ultrasonography
Verified
Journal Article
Open access
PDF file
QWQiao Wang
Qiao Wang
WRWeiwei Ren
Weiwei Ren
LWLifan Wang
Lifan Wang
XLXiaolong Li
Xiaolong Li
AZAnqi Zhu
Anqi Zhu
LSLiping Sun
Liping Sun
Purpose: This study examined the diagnostic value of high-frequency ultrasound (HFUS) features in differentiating between benign and malignant skin lesions.Methods: A total of 1,392 patients with 1,422 skin lesions who underwent HFUS examinations were included in an initial dataset (cohort 1) to identify features indicative of malignancy. Qualitative clinical and HFUS characteristics were recorded for all lesions. To determine which HFUS and clinical features were suggestive of malignancy, univariable and multivariable logistic regression analyses were employed. The diagnostic performance of HFUS features combined with clinical information was evaluated. This assessment was validated using internal data (cohort 2) and multicenter external data (cohort 3).Results: Features significantly associated with malignancy included age above 60 years; lesion location in the head, face, and neck or genital regions; changes in macroscopic appearance; crawling or irregular growth pattern; convex or irregular base; punctate hyperechogenicity; blood flow signals; and feeding arteries. The area under the receiver operating characteristic curve, sensitivity, and specificity of HFUS features combined with clinical information were 0.946, 92.5%, and 86.9% in cohort 1; 0.870, 93.1%, and 80.8% in cohort 2 (610 lesions); and 0.864, 86.2%, and 86.6% in cohort 3 (170 lesions), respectively. However, HFUS is not suitable for evaluating lesions less than 0.1 mm in thickness or lesions exhibiting surface hyperkeratosis.Conclusion: In a clinical setting, the integration of HFUS with clinical information exhibited good diagnostic performance in differentiating malignant and benign skin lesions. However, its utility was limited in evaluating extremely thin lesions and those exhibiting hyperkeratosis.

10 September 2023 in Skin Research and Technology
Verified
Journal Article
Open access
YMYao Miao
Yao Miao
WRWei‐Wei Ren
Wei‐Wei Ren
FYFei‐Yue Yang
Fei‐Yue Yang
LLLiang Li
Liang Li
LWLing Wu
Ling Wu
LGLe-Hang Guo
Le-Hang Guo
Background: It is unknown whether high‐frequency ultrasound (HFUS) can evaluate invisible subcutaneous lesions. We aimed to investigate the diagnostic value of HFUS in invisible subcutaneous lesions.Method: Patients with invisible subcutaneous lesions were prospectively recruited from two centres. Before undergoing biopsy or surgery, each lesion was independently evaluated by two clinicians. One provides a clinical diagnosis by only clinical examination and the other provides an integrated diagnosis by combining clinical examination and HFUS information. Diagnoses were classified as correct, wrong, and indeterminate. A total of 391 lesions from 355 patients were enrolled, including 225 epidermoid cysts, 77 lipomas, 25 pilomatrixomas, 21 haemangiomas, 19 dermatofibromas, 11 dermatofibrosarcoma protuberans (DFSP), 7 neurofibromas, and 6 leiomyomas. Using pathological results as the gold standard, diagnostic performance was compared.Results: The number of correct diagnoses increased from 185 (47.3%) by clinical examination alone to 316 (80.8%) after the addition of HFUS (P < 0.05). Meanwhile, the indeterminate diagnosis rate decreased from 143 (36.6%) to 10 (2.6%). Using HFUS, the accuracy improved significantly for epidermoid cysts (59.6% vs. 86.7%), lipomas (50.6% vs. 94.8%), pilomatrixomas (0% vs. 48.0%), haemangiomas (23.8% vs. 57.1%), and DFSPs (0% vs. 81.8%) (all p < 0.05). However, HFUS did not significantly improve the diagnostic accuracy of dermatofibromas (15.8% vs. 21.1%, p > 0.999), neurofibromas (42.9% vs. 71.4%, p = 0.625), or leiomyomas (16.7% vs. 100%, p = 0.063).Conclusion: Combining HFUS and clinical examination can generally improve the diagnostic accuracy and decrease the indeterminacy of invisible subcutaneous lesions, especially epidermoid cysts, lipomas, pilomatrixomas, haemangiomas, and DFSPs. However, for some rare lesions, HFUS cannot provide useful information.

5 March 2022 in Ultrasonography
Verified
Journal Article
Open access
PDF file
XLXiao-Long Li
Xiao-Long Li
YSYi-Kang Sun
Yi-Kang Sun
QWQiao Wang
Qiao Wang
ZCZi-Tong Chen
Zi-Tong Chen
ZQZhe-Bin Qian
Zhe-Bin Qian
HXHuixiong Xu
Huixiong Xu
Purpose: This study investigated the value of synchronous tele-ultrasonography (TUS) for naive operators in thyroid ultrasonography (US) examinations.Methods: Ninety-seven patients were included in this prospective, parallel-controlled trial. Thyroid scanning and diagnosis were completed by resident A independently, resident B with guidance from a US expert through synchronous TUS, and an on-site US expert. The on-site expert’s findings constituted the reference standard. Two other off-site US experts analyzed all data in a blind manner. Inter-operator consistency between the two residents and the on-site US expert for thyroid size measurements, nodule measurements, nodule features, American College of Radiology (ACR) Thyroid Imaging Reporting and Data System (TI-RADS) categories, and image quality was compared. Two questionnaires were completed to evaluate the clinical benefit.Results: Resident B detected more nodules consistent with the on-site expert than resident A did (89.4% vs. 56.5%, P0.75), while resident A achieved lower consistency in ACR TI-RADS categories, composition, echogenicity, margin, echogenic foci, and vascularity (all ICCs 0.40-0.75). Residents A and B had excellent consistency in target nodule measurements (all ICCs >0.75). Resident B achieved better performance than resident A for gray values, time gain compensation, depth, color Doppler adjustment, and the visibility of key information (all P<0.05). Furthermore, 61.9% (60/97) of patients accepted synchronous TUS, and 59.8% (58/97) patients were willing to pay for it.Conclusion: Synchronous TUS can help inexperienced residents achieve comparable thyroid diagnostic capability to a US expert.

25 October 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
DLDan-Hua Li
Dan-Hua Li
FYFeiyue Yang
Feiyue Yang
YZYang Zhao
Yang Zhao
QWQiao Wang
Qiao Wang
WRWeiwei Ren
Weiwei Ren
CQChuan Qin
Chuan Qin
Background: Dermatofibroma has various pathological classifications, some of which pose a risk of recurrence and metastasis. Distinguishing these high-risk dermatofibromas based on appearance alone can be challenging. Therefore, high-frequency ultrasound may provide additional internal information on these lesions, helping to identify high-risk and low-risk dermatofibroma early. Methods: In this retrospective study, 50 lesions were analyzed to explore the correlation between clinical and high-frequency ultrasound features and dermatofibroma risk level. Based on their pathological features, the lesions were divided into high-risk (n = 17) and low-risk (n = 33) groups. Subsequently, an identification model based on significant high-frequency ultrasound features was developed. Results: Significant differences were observed in the thickness, shape, internal echogenicity, stratum basal, and Doppler vascular patterns between the high-risk and low-risk groups. The median lesion thickness for the high-risk dermatofibroma group was 4.1 mm (IQR: 3.2–6.1 mm), while it was 3.1 mm (IQR: 1.3–4.2 mm) for the low-risk dermatofibroma group. In the high-risk dermatofibroma group, irregular morphology was predominant (70.6%, 12/17), the most common being dermis-to-subcutaneous soft tissue penetration (64.7%, 11/17), and heterogenous internal echogenicity was observed in the majority of cases (76.5%, 13/17). On the other hand, regular morphology was more prevalent in the low-risk dermatofibroma group (78.8%, 26/33), primarily limited to the dermis layer (78.8%, 26/33), with homogeneous internal echogenicity also being prevalent in the majority of cases (81.8%, 27/33). Regarding the Doppler vascularity pattern, 69.7% (23/33) of low-risk dermatofibromas had no blood flow, while 64.7% (11/17) of high-risk dermatofibromas had blood flow. Conclusion: High-frequency ultrasound is crucial in distinguishing high-risk and low-risk dermatofibromas, making it invaluable for clinical management.