Chuan Qin

Dr. Chuan Qin


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 October 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
DLDan-Hua Li
Dan-Hua Li
FYFeiyue Yang
Feiyue Yang
YZYang Zhao
Yang Zhao
QWQiao Wang
Qiao Wang
WRWeiwei Ren
Weiwei Ren
CQChuan Qin
Chuan Qin
Background: Dermatofibroma has various pathological classifications, some of which pose a risk of recurrence and metastasis. Distinguishing these high-risk dermatofibromas based on appearance alone can be challenging. Therefore, high-frequency ultrasound may provide additional internal information on these lesions, helping to identify high-risk and low-risk dermatofibroma early. Methods: In this retrospective study, 50 lesions were analyzed to explore the correlation between clinical and high-frequency ultrasound features and dermatofibroma risk level. Based on their pathological features, the lesions were divided into high-risk (n = 17) and low-risk (n = 33) groups. Subsequently, an identification model based on significant high-frequency ultrasound features was developed. Results: Significant differences were observed in the thickness, shape, internal echogenicity, stratum basal, and Doppler vascular patterns between the high-risk and low-risk groups. The median lesion thickness for the high-risk dermatofibroma group was 4.1 mm (IQR: 3.2–6.1 mm), while it was 3.1 mm (IQR: 1.3–4.2 mm) for the low-risk dermatofibroma group. In the high-risk dermatofibroma group, irregular morphology was predominant (70.6%, 12/17), the most common being dermis-to-subcutaneous soft tissue penetration (64.7%, 11/17), and heterogenous internal echogenicity was observed in the majority of cases (76.5%, 13/17). On the other hand, regular morphology was more prevalent in the low-risk dermatofibroma group (78.8%, 26/33), primarily limited to the dermis layer (78.8%, 26/33), with homogeneous internal echogenicity also being prevalent in the majority of cases (81.8%, 27/33). Regarding the Doppler vascularity pattern, 69.7% (23/33) of low-risk dermatofibromas had no blood flow, while 64.7% (11/17) of high-risk dermatofibromas had blood flow. Conclusion: High-frequency ultrasound is crucial in distinguishing high-risk and low-risk dermatofibromas, making it invaluable for clinical management.

5 January 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
YZYang Zhao
Yang Zhao
FYFeiyue Yang
Feiyue Yang
DLDan-Hua Li
Dan-Hua Li
QWQiao Wang
Qiao Wang
LGLe-Hang Guo
Le-Hang Guo
CQChuan Qin
Chuan Qin
Introduction: The Breslow thickness of cutaneous melanoma (CM) is related to the surgical approach and is usually measured using a preoperative biopsy. However, tumor thickness is often underestimated by partial biopsies. Objectives: To identify whether high-frequency ultrasound (HFUS) can improve the accuracy of preoperative detection of Breslow thickness. Methods: Partial biopsies and HFUS measurements of Breslow thickness were analyzed in 17 patients with CM. Postoperative histopathologic examination is considered the gold standard. In different thicknesses, HFUS and partial biopsy were compared with postoperative pathology and their effects on tumor T staging and surgical margins. Results: The mean (±SD) Breslow thicknesses measured using HFUS, partial biopsy, and postoperative histopathology were 3.5 ± 2.2 mm, 1.8 ± 1.1 mm, and 3.2 ± 2.1 mm, respectively. The correlation coefficients were 0.76 (partial biopsy and postoperative histopathology) and 0.96 (HFUS and postoperative histopathology), respectively (all p < 0.01). Partial biopsy underestimated the Breslow thickness, and with a gradual increase in CM thickness, the underestimation became increasingly obvious. Partial biopsy led to an underestimation of T staging of the tumor in 8 (8/17 [47.1%]) patients, 4 (4/8 [50.0%]) of whom may have had insufficient surgical peripheral margins. Conversely, HFUS exhibited a significant downward trend of underestimation (0/17 [0%], p = 0.003). However, only 2 (2/17 [11.8%]) patients had slight overestimation for T staging (p = 0.485), and none of the overestimations changed the surgical margins. Conclusions: HFUS can provide an accurate preoperative assessment of Breslow thickness, and correlates better with postoperative histopathology.

23 December 2024 in Frontiers in Medicine
Verified
Journal Article
Open access
PDF file
YZYang Zhao
Yang Zhao
EZEr-Ke Zhang
Er-Ke Zhang
DLDan-Hua Li
Dan-Hua Li
YZYu-Jing Zhou
Yu-Jing Zhou
HJHui Jiang
Hui Jiang
CQChuan Qin
Chuan Qin
Purpose: Acute fatty liver of pregnancy (AFLP) is a severe complication that can occur in the third trimester or immediately postpartum, characterized by rapid hepatic failure. This study aims to explore the changes in portal vein blood flow velocity and liver function during pregnancy, which may assist in the early diagnosis and management of AFLP.Methods: This longitudinal study was conducted at a tertiary healthcare center with participants recruited from routine antenatal check-ups. The study included healthy women aged 20–40 years with singleton pregnancies. Doppler ultrasonography was used to assess portal vein flow and velocity, complemented by standard laboratory tests to monitor liver function. A nomogram model integrating the clinical features and Doppler ultrasonography parameters was constructed using logistic regression analysis for differentiating AFLP from normal controls.Results: A total of 135 women were enrolled, divided into control and AFLP groups. The AFLP group demonstrated a significant reduction in portal vein flow velocity and alterations in liver dimensions. Laboratory tests indicated elevated liver enzymes and altered lipid profiles in the AFLP group. Statistical analysis showed that portal vein flow velocity could be a sensitive marker for predicting liver dysfunction in AFLP. The area under the receiver operating characteristic (ROC) curves (AUC) of the nomogram model were 0.88 (95% confidence interval [CI]: 0.82–0.95) with specificity, sensitivity, negative predictive value, and positive predictive value of 67.8, 95.0, 95.0, and 67.8, respectively, in the training cohort and 0.86 (95% CI: 0.72–0.98) and 86.9, 75.0, 83.3, and 80.0 in the test cohort, respectively. The calibration curves demonstrated good agreement between the predicted and observed probability for predicting AFLP.Conclusion: The study underscores the potential of using portal vein flow velocity as an early diagnostic marker for AFLP in pregnant women. Further research is required to establish standardized diagnostic thresholds for portal vein flow measurements.

10 June 2026 in Frontiers in Oncology
Verified
Journal Article
Open access
PDF file
YZYang Zhao
Yang Zhao
YZYujing Zhao
Yujing Zhao
DLDan-Hua Li
Dan-Hua Li
TLTing Liang
Ting Liang
DSDan-Dan Shan
Dan-Dan Shan
CQChuan Qin
Chuan Qin
Objective: To develop a High-frequency ultrasound (HFUS)-based predictive nomogram integrating clinical and ultrasound features for distinguishing malignant from benign skin tumors. Methods: This retrospective study enrolled 185 patients who underwent preoperative HFUS examination for skin tumors. Patients were randomly divided into training (n=130; 73 malignant, 57 benign) and validation (n=55; 31 malignant, 24 benign) cohorts. Clinical characteristics and ultrasound features were systematically analyzed. Univariate and multivariate logistic regression analyses were used to identify independent predictors of malignancy, which were incorporated into a nomogram. Model performance was evaluated using receiver operating characteristic (ROC) curves, calibration plots, and decision curve analysis (DCA). Results: Malignant tumors demonstrated significantly greater multilayer involvement, irregular margins, heterogeneous echogenicity, raised surface morphology, and abundant intralesional vascularity compared to benign tumors (all P<0.001). Multivariate analysis identified five independent predictors of malignancy: advanced age (OR = 1.01, 95% CI: 1.00 - 1.01), multilayer involvement (OR = 1.19, 95% CI: 1.12 - 1.26), unclear margins (OR = 1.36, 95% CI: 1.21 - 1.54), raised surface morphology (OR = 1.10, 95% CI: 1.01 - 1.21), and heterogeneous echogenicity (OR = 1.09, 95% CI: 0.99 - 1.21). The nomogram achieved area under the curve (AUC) values of 0.98 (95% CI 0.95-1.00) in the training cohort and 0.98 (95% CI 0.95-1.00) in the validation cohort. Conclusions: HFUS provides valuable information for preoperative evaluation of skin tumors. The nomogram demonstrates good diagnostic performance and clinical utility for distinguishing malignant from benign skin tumors.