Shuai Jiang

Mr. Shuai Jiang


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 December 2018 in Energies
Verified
Journal Article
Open access
PDF file
SJShuai Jiang
Shuai Jiang
WWWeifeng Wang
Weifeng Wang
Aizhu ZhangAizhu Zhang
Aizhu Zhang
WZWeiwei Zhou
Weiwei Zhou
Covert fault zone is an important type of geological phenomenon that is closely related to hydrocarbon formation and distribution but has often been overlooked because it lacks obvious fault displacement and fault plane. To meet this challenge, a novel cognitive framework is proposed in this study, in which criteria for identifying the existence of covert fault zone are developed based on the regional tectonic backgrounds and geophysical data. The Riedel shear model is then utilized to analyze the genetic mechanism of the covert fault zone. The Mohr-Coulomb theory is also introduced to conduct a structural physical simulation to interpret the evolution process of the covert fault zone. Information about the genetic mechanism and evolution of the covert fault zone is finally combined to determine the oil-controlling mode. The study site is Qikou Sag in Eastern China. It is found that the covert fault zone in Qikou Sag meets four recognition criteria and is generated by the stress transferred from the strike-slip activity of the basement fault. Moreover, it can be concluded that the covert fault zone in Qikou Sag contains five evolution stages and controls the reservoir mainly via three aspects, that is, sedimentary sand, subtle traps and oil accumulation mode.

11 October 2023 in Energies
Verified
Journal Article
Open access
PDF file
PLPeng Liu
Peng Liu
YWYa Jing Wang
Ya Jing Wang
ZLZhao Liang
Zhao Liang
ZZZhikai Zhang
Zhikai Zhang
JRJun Rao
Jun Rao
SJShuai Jiang
Shuai Jiang
To prevent liquid leakage during the phase transition of a phase change material (PCM), a novel form-stable PCM (FSPCM) based on LA/CIT/CNT was fabricated using a simple and facile direct impregnation method. The iron tailings (ITs) was calcinated at first. And then lauric acid (LA) was impregnated into the calcinated iron tailings (CITs) with carbon nanotubes (CNTs) as a thermal conductivity additive. Subsequently, the leakage tests and the properties of the prepared samples were investigated by diffusion-oozing testing (DOT), SEM, XRD, FTIR, DSC, TGA, and intelligent paperless recorder (IPR). DOT results showed that the impregnation ratio of LA into the CIT and CNT was up to 27.5% without leakage. SEM indicated that LA can be adsorbed into microscale pores and covered the surface of CITs and CNTs. FTIR spectra indicated that there was no chemical reaction during the preparation process. The melting and freezing temperatures of the prepared LA/CIT/CNT FSPCMs were measured as 45.24 °C and 39.61 °C, respectively. Correspondingly, the latent heat values were determined as 39.95 J/g and 35.63 J/g, respectively. The LA/CIT/CNT FSPCMs exhibited good thermal stability in the working temperature range, and its heat transfer efficiency was improved significantly by 69.23% for LA and 84.62% for LA/CIT FSPCM. In short, LA/CIT/CNT FSPCMs are a very promising material for thermal energy storage in practical low-temperature applications.

28 July 2023 in Energies
Verified
Journal Article
Open access
PDF file
PLPeng Liu
Peng Liu
Xinglan CuiXinglan Cui
Xinglan Cui
YWYa Jing Wang
Ya Jing Wang
ZZZhikai Zhang
Zhikai Zhang
JRJun Rao
Jun Rao
XGXiaobin Gu
Xiaobin Gu
Fly ash is a kind of industrial solid waste that is considered “hazardous waste”. In this study, a supporting matrix of modified fly ash (MFA) was employed to package lauric acid (LA) via a facile direct impregnation method involving less experimental error. A low-cost and eco-friendly form-stable phase change material (PCM) of LA/MFA/graphene (G) was fabricated, with G as the thermal conductivity enhancer. The preparation and leakage testing of an LA/MFA/G form-stable PCM (FSPCM) were investigated in detail. The leakage test results indicated that good package efficiency was obtained using MFA with a higher specific surface area and richer pore structure to pack the LA. Then, LA/MFA/G composites were characterized via scanning electronic microscope (SEM), Fourier transform infrared spectroscope (FTIR), differential scanning calorimeter (DSC), and thermal gravimetric analyzer (TGA). The results showed that excellent form stability was obtained by adding MFA as the supporting matrix. The SEM analysis indicated that LA could be well dispersed into the structure of MFA. The FTIR analysis demonstrated that the components of the FSPCM were quite compatible. The results of the DSC illustrated that LA/MFA/G (5 wt. %) had a melting point of 45.38 °C and a latent heat of 41.08 J/g. The TGA analysis revealed that the prepared FSPCM had better thermal stability compared with LA within its working temperature range. In addition, the effects of G on the heat transfer performance of the prepared FSPCM were examined. In short, using MFA with a higher specific surface area and richer pore structure to pack the LA via a simple preparation process with less experimental error can contribute to good performance. The research not only improved the comprehensive utilization of solid waste, but also promotes the application of FSPCM in the field of building energy conservation.