Statement of problem: Recent advancements in digital technology have revolutionized implant dentistry, particularly with additively manufactured subperiosteal jaw implants (AMSJIs). These implants allow patient-specific designs that adapt to anatomical requirements. However, optimizing stress distribution remains a challenge. Purpose: This study evaluated the stress distribution in AMSJIs and surrounding bone by analyzing different framework materials (PEEK and Co-Cr), anterior wing designs (I- and Y-shaped), and cantilever extensions using three-dimensional finite element analysis. Methods: A model was created from a patient with an atrophic, edentulous maxilla. Biomechanical evaluation of eight maxillary implant scenarios was performed under a 200 N force applied at a 45° oblique angle. Stress distribution in the bone, implants, screws, and prosthetic frameworks, as well as prosthetic displacement, was analyzed. Results: The lowest implant stress (444.5 MPa) was observed in the Co-Cr group without a cantilever using an I-shaped design, whereas the highest stress (623.0 MPa) occurred in the Co-Cr group with a cantilever using a Y-shaped design. Prosthetic displacement was greater in cantilevered groups, with PEEK exhibiting more displacement than Co-Cr. Conclusions: The optimal stress distribution was achieved with the I-shaped design without a cantilever, using Co-Cr. Stress levels were significantly influenced by framework material, wing design, and cantilever presence, underscoring the importance of design and material selection. Clinical significance: While stress remained within physiological limits in all cases, avoiding cantilevers and selecting a rigid material can optimize Y-shaped designs. PEEK demonstrated favorable properties in cantilevered designs, but its long-term effects on soft tissue and implants warrant further clinical trials.
Maxillectomy defects may vary from localized to extensive soft and hard tissue loss. In addition to physical and psychologic damages, functional and aesthetic aspects must be restored. This clinical report describes the rehabilitation of a patient with a zygoma implant-supported obturator prosthesis caused by a subtotal bilateral maxillectomy due to a squamous oral cell carcinoma. Prosthetic rehabilitation of this patient was performed after zygoma implant surgery. A maxillary obturator prosthesis supported by 2 osseointegrated zygoma implants was fabricated. Despite limited mouth opening and anatomic deficiencies, the patient's aesthetic and functional demands were fulfilled.
The aim of this study was to investigate the effects of Bioglue as a mechanical barrier with or without biphasic calcium phosphate (BCP) in a rat tibia model. Sixty Sprague Dawley male rats weighing 250 ± 20 g and 10 to 12 weeks of age were studied. Unicortical defects were created on the right tibia of all rats. Subjects were randomly divided into 3 groups. BioGlue group (24 rats); BioGlue alone, Graft group (24 rats); BioGlue + BCP and Control group; unfilled and uncovered (12 rats). Animals were euthanized at 7th, 21st, and 45th days postoperatively for histological and histomorphometric analyses. BioGlue material exhibited no adverse effects until the end of observation period. Bone-healing scores did not differ statistically between Control and BioGlue group, but found to be lower in Graft group on 21st and 45th days, (P < 0.001 and P < 0.01 on the 21st day and P < 0.01 and P < 0.05 on the 45th day, respectively). New bone formation in Graft group was found to be statistically different from Control group on the 7th and 21st days (P < 0.01 and P < 0.05 respectively), whereas no statistical difference was observed between BioGlue and Control group at all times. The present analysis indicates that BioGlue functioned well as a mechanical barrier allowing new bone formation. No additional benefit of combination treatment was detected in this study design and BCP did not offer any advantage for bone regeneration, thus it can serve as only a space maintainer.