ERKAN SANCAKLI

Dr. ERKAN SANCAKLI

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 October 2015 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
ESERKAN SANCAKLI
ERKAN SANCAKLI
BGBilge Gokcen-Rohlig
Bilge Gokcen-Rohlig
ABAli Balık
Ali Balık
DÖDeğer Öngül
Değer Öngül
SKSelin Kıpırdı
Selin Kıpırdı
HKHaluk Keskın
Haluk Keskın
To evaluate the effect of Low Level Laser (LLL) application at the points of greatest pain in patients with chronic masticatory muscle pain. A total number of 30 (21 women, 9 men, with a mean age of 39.2) were selected after the diagnosis of MPDS according to the Research Diagnostic Criteria for Temporomandibular Disorder (RDC/TMD). The patients were randomly divided into three groups; laser group I (n = 10); patients received the LLL at the point of greatest pain, laser group II (n = 10); patients received LLL at pre-established points in the effected muscles and placebo group (n = 10). LLL and placebo were applied three times per week, for a total of 12 sessions. Mandibular mobility was examined, masticator muscles tenderness were assessed and PPT values were obtained. Subjective pain levels were evaluated using VAS. The measurements performed before the treatment and after the completion of the therapy. Descriptive statistics (mean, standard deviation, and frequency) Student’s t-test, Mann–Whitney U-test and paired-sample t-tests were used for analysis. In both laser groups, there was a statically significant reduction in PPT values of the muscles, number of muscles without any pain on palpation increased significantly, mandibular movements’ ranges were improved. Laser group I demonstrated statistically better results than the Laser group II in all of the measured values. Plasebo group did not show any statistically difference in any of the measured values. LLLT can be accepted as an alternative treatment modality in the management of masticatory muscle pain and direct irradiation seems to effect better. Current Controlled Trials ISRCTN31085 , Date of registration 28/08/20145.

1 February 2016 in Journal of Oral Implantology
Verified
Journal Article
Open access
ABAli Balik
Ali Balik
MOMeltem Ozdemir-Karatas
Meltem Ozdemir-Karatas
KPKadriye Peker
Kadriye Peker
ECEbru Demet Cifter
Ebru Demet Cifter
ESERKAN SANCAKLI
ERKAN SANCAKLI
BGBilge Gokcen-Rohlig
Bilge Gokcen-Rohlig
Maxillofacial defects may be reconstructed by plastic surgery or treated by prosthetic mean rehabilitation. In case of large defects, prosthetic rehabilitation rather than surgical reconstruction is preferred due to the insufficient esthetic results of surgical interventions. However, retention of the craniofacial prosthesis is a great problem despite the satisfactory esthetic results. With the presentation of extraoral implants, the retention of maxillofacial prostheses was improved, and osseointegrated craniofacial implants have become indispensable for retention and stability. However, there are conflicting results regarding the success rates of osseointegrated implants used at the craniofacial region. A total of 24 patients with 64 implants (30 in auricular region of 13 patients, 24 in nasal region of 8 patients, and 10 in orbital region of 3 patients) ranging in age from 16 to 83 years (mean age = 45.45 years) were evaluated. One patient among 13 patients (1/13) has lost his implants in the auricular area, 1 patient among 8 patients (1/8) lost his implants, and 1 patient among 3 patients (1/3) has lost all of her implants. Peri-implant soft tissue response was evaluated for a 60-month period and a total of 654 visits/sites recorded. Grade 0 (no irritation) was present in 72.8% (476/654) of the visits/sites. Grade 1 (slight redness) was observed for 18.8% (123/654). Grade 2 (red and slightly moist tissue) was scored in 6.9% (45/654). Grade 3 (red and slightly moist tissue with granulation) was noted in 1.5% (10/654) and grade 4 (infection) could not be found. Ossseointegrated implants provide reasonable support and show successful results when used with maxillofacial prostheses.

19 June 2019 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
ECEbru Demet Cifter
Ebru Demet Cifter
MOMeltem Ozdemir-Karatas
Meltem Ozdemir-Karatas
ACAdem Cinarli
Adem Cinarli
ESERKAN SANCAKLI
ERKAN SANCAKLI
ABAli Balik
Ali Balik
GEGulumser Evlioglu
Gulumser Evlioglu
The inherent colour change in maxillofacial silicone elastomers becomes perceptible 6–12 months after fabrication. Determining the factors that accelerate the degradation of the prosthesis can help the clinicians increase its life span. Therefore, the aim of the study was to investigate the effect of time passage, processing temperature, and molding-stone colour on the colour change of maxillofacial silicone elastomers after darkroom storage for 6000 h. A total of ten study molds, each incorporating ten specimen gaps were fabricated using five different colors of dental stones. The gaps were filled with coloured Cosmesil M511 maxillofacial silicone elastomer. Five of the study molds, one of each stone color, were processed at room temperature (25 °C) for 24 h while the remainder were vulcanized at 100 °C for 1 h. Two stainless-steel molds were also fabricated to obtain a total of twenty control-group specimens of the same dimensions that were processed under the same conditions as the study molds. Colour measurements of the vulcanized silicone samples were performed using a Konica Minolta spectrophotometer. Initial measurements were obtained after the blocks were removed from the molds and the final measurements were recorded 6000 h after storage in the dark at 25 °C and 40% relative humidity. The CIEDE2000 colour-difference formula was used to measure the changes in the colour. One-way and two-way ANOVA, and an independent-sample t-test were used for statistical assessments. For every group, the colour change exceeded the perceptible thresholds. Thus, either the vulcanization temperature or the colour of the molding stone has a significant effect on the colour change over time. Those samples vulcanized in green and white molding stones at 100 °C exhibited a significantly higher ∆L*, ∆a*, and ∆b* values relative to the samples vulcanized at room temperature. The molding-stone colour and vulcanization temperature both affect the degree of colour change after storage in a dark environment. The L*, a*, and b* values for the maxillofacial silicone elastomers are influenced by the direction of the increase or decrease according to the selected colour. This effect varies as the temperature increases.

31 March 2017 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
ECEbru Demet Cifter
Ebru Demet Cifter
MKMeltem Ozdemir – Karatas
Meltem Ozdemir – Karatas
Emrah BacaEmrah Baca
Emrah Baca
ACAdem Cinarli
Adem Cinarli
ABAli Balik
Ali Balik
BGBilge Gokcen-Rohlig
Bilge Gokcen-Rohlig
Colour degradation is a major problem in maxillofacial silicone elastomers. Recent studies have focused on colour stability and the mechanical properties of the silicone elastomers. A colour match is also essential for the acceptance of the prosthesis by the patient. The aim of this study is to assess the colour degradation of the silicone elastomer after being moulded in different colours of dental stones at two different vulcanization temperatures. Five different colours of dental stones were used to fabricate a total of 120 silicone blocks using a Cosmesil M511 maxillofacial silicone elastomer. Vulcanization was completed at two different temperatures (25 and 100° Celsius). Colour measurements were obtained with a Conica Minolta spectrophotometer. The CIEDE2000 formula was used to calculate the colour differences (∆E00). Two-way ANOVA, one-way ANOVA with Bonferroni corrected post-hoc p values and independent samples t-test were used for the statistical analyses. High temperature vulcanization causes lightening of the maxillofacial silicone elastomers without regard to the dental stone colour (p = 0.001). Specimens moulded in green stone lightened least at room temperature (p = 0.999). Compared to the control group, at high temperature, all specimens moulded in coloured dental stones darkened significantly (p < 0.001 for white, blue and yellow; p = 0.006 for green; p = 0.045 for reddish-brown). In the high temperature group, the shift to a green chroma was significant in the white, yellow and green dental stones groups (p = 0.001, p = 0.002, p < 0.001, respectively). The mean b* of the high temperature control group was higher than that of the room temperature control group (p < 0.001). The only ∆E00 score lower than the perceptibility threshold for dental materials (∆E00 = 1.30) was between the room temperature control group and the room temperature green dental stone group (∆E00 = 0.96). Green and blue dental stones cause less colour degradation in silicone elastomers. Reddish-brown dental stones cause the most colour degradation in silicone elastomers. At 100 °C, the colour of the silicone elastomer lightens and yellows even if the elastomer is vulcanized in a stainless steel mould. White, yellow and reddish-brown dental stones make the silicone elastomer appear more yellow even if the elastomer is vulcanized at room temperature.

1 October 2015 in Journal of Craniofacial Surgery
Verified
Journal Article
Closed access
TCTamer Celakil
Tamer Celakil
DADemet Çağıl Ayvalıoğlu
Demet Çağıl Ayvalıoğlu
ESERKAN SANCAKLI
ERKAN SANCAKLI
BABelir Atalay
Belir Atalay
OOOzge Doganay Ozyilmaz
Ozge Doganay Ozyilmaz
KKKivanc Bektas Kayhan
Kivanc Bektas Kayhan
Maxillectomy defects may vary from localized to extensive soft and hard tissue loss. In addition to physical and psychologic damages, functional and aesthetic aspects must be restored. This clinical report describes the rehabilitation of a patient with a zygoma implant-supported obturator prosthesis caused by a subtotal bilateral maxillectomy due to a squamous oral cell carcinoma. Prosthetic rehabilitation of this patient was performed after zygoma implant surgery. A maxillary obturator prosthesis supported by 2 osseointegrated zygoma implants was fabricated. Despite limited mouth opening and anatomic deficiencies, the patient's aesthetic and functional demands were fulfilled.

17 January 2023 in Clinical and Experimental Health Sciences
Verified
Journal Article
Closed access
HÖHatice Banu Özel
Hatice Banu Özel
YAYilmaz Umut Aslan
Yilmaz Umut Aslan
ESERKAN SANCAKLI
ERKAN SANCAKLI
Objective: With the widespread use of CAD/CAM (computer aided design and manufacture) systems in dentistry, many restorative materials have been produced. In our study, we aimed to evaluate the change in optical properties of newly developed translucent monolithic zirconia (TMZ) (Cercon HT Dentsply, Sirona, USA), zirconia-reinforced lithium silicate (ZLS) (Celtra Duo, Dentsply, Germany) and lithium disilicate (LS2) (IPS e.max CAD, Ivoclar Vivadent, Liechtenstein) materials with aging. Methods:10 discs of 12mm diameter and 1.2 mm thickness were produced from high translucent A2 color of each material. The aging process was applied in an autoclave under 134ºC, 0.2MPa pressure. For optical evaluation, L*, a*, b* values of the samples were measured by spectrophotometry before aging, after 3 hours and 6 hours aging. ΔE00 values and translucency parameters (TP) were calculated. The data were evaluated statistically. Results: In the present study, all the materials had undergone color change as a result of aging, but this change was within acceptable limits (ΔE00 0.8). There was a decrease in the translucency of all materials used in the study, but this decrease was not statistically significant. Conclusion: In the light of the findings obtained from this in vitro study, aging did not cause color and translucency changes in TMZ, ZLS, LS2 monolithic CAD/CAM materials.