The temperature dependence of core mode resonance has been thoroughly studied in fiber Bragg gratings (FBGs), but it is not the case for cladding mode resonances in multi-resonance gratings such as tilted FBGs (TFBGs). In this work, the temperature sensitivity of ultraviolet written TFBGs in SMF-28 fibers is assessed, demonstrating in the first, to the best of our knowledge, place that a single gauge factor can be employed to characterize the response to temperature of the resonances over the full spectrum in the 10°–50°C range. Then, a simulation model is obtained, enabling to predict TFBG spectra in the 10°–50°C range with high accuracy. This requires a calibration of the core index and dispersion of the TFBG measured in air at 25°C, and determination of the glass refractive index thermo-optic coefficient ( , common to both core and cladding glasses), leading to a mean error on the wavelength position of resonances between 1 and 3 pm. This mean error can be further reduced (less than 1 pm) by considering a linear dependence with temperature of . Therefore, this model will enable to completely remove the temperature-induced shifts of all resonances in TFBG sensing applications and measure with great accuracy the variables of interest by using the scaled averages of groups of resonances instead of (less accurate) individual shifts.
A novel kind of fiber optic ultrasonic sensor based on matching fiber Bragg gratings (FBGs) is proposed and demonstrated. The sensors consist of a pair of matching FBGs fixed to a special bracket. The bracket plays a role in stretching and squeezing the FBGs, with the push–pull effect efficiently coupling the ultrasonic signal to the sensor, thus, improving the sensor’s sensitivity. Side-band filtering technology-based intensity interrogation was used to detect ultrasounds in water. With the synergic effect of the matching FBGs, the sensor performed with a high signal-to-noise ratio (56.9 dB at 300 KHz, 53 dB at 1 MHz and 31.8 dB at 5 MHz) and the observed ultrasonic sinusoidal signals were undistorted and distinguishable in the time domain.
A sensitivity-improved ultrasonic sensor is proposed and demonstrated experimentally in this present study. The device is comprised only a fiber-optic microcavity that is formed by discharging a short section of hollow core fiber (HCF). The key to ensuring the success of the sensor relies on the preprocessing of hydrogen loading for HCF. When discharging the HCF, the hydrogen is heated up during the formation of the air bubble, which enlarges the bubble diameter, smoothens its surfaces simultaneously and decreases Young’s modulus of the material of the bubble. Ultimately, this results in the probe being highly sensitive to ultrasound with a SNR of 69.28 dB. Once the compact air cavity is formed between the end face of the leading-in fiber and the top wall of the bubble, a well-defined interference spectrum is achieved based on the Fabry–Perot interference. By using spectral side-band filtering technology, we detect the ultrasonic waves reflected by the seismic physical model (SMF) and then reconstruct its three-dimensional image.