Timm Dirrichs

Dr. Timm Dirrichs

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2016 in Academic Radiology
Verified
Journal Article
Closed access
TDTimm Dirrichs
Timm Dirrichs
VQValentin Quack
Valentin Quack
MGMatthias Gatz
Matthias Gatz
MTMarkus Tingart
Markus Tingart
CKChristiane K. Kuhl
Christiane K. Kuhl
SSSimone Schrading
Simone Schrading

1 March 2018 in Academic Radiology
Verified
Journal Article
Closed access
TDTimm Dirrichs
Timm Dirrichs
VQValentin Quack
Valentin Quack
MGMatthias Gatz
Matthias Gatz
MTMarkus Tingart
Markus Tingart
BRBjörn Rath
Björn Rath
SSSimone Schrading
Simone Schrading

1 June 2023 in Radiology
Verified
Journal Article
Closed access
TDTimm Dirrichs
Timm Dirrichs
ETEric Tietz
Eric Tietz
ARAndré Rüffer
André Rüffer
JHJens Hanten
Jens Hanten
TNThai Duy Nguyen
Thai Duy Nguyen
CKChristiane K. Kuhl
Christiane K. Kuhl
Background Photon-counting CT (PCCT) has been shown to improve cardiovascular CT imaging in adults. Data in neonates, infants, and young children under the age of 3 years are missing. Purpose To compare image quality and radiation dose of ultrahigh-pitch PCCT with that of ultrahigh-pitch dual-source CT (DSCT) in children suspected of having congenital heart defects. Materials and Methods This is a prospective analysis of existing clinical CT studies in children suspected of having congenital heart defects who underwent contrast-enhanced PCCT or DSCT in the heart and thoracic aorta between January 2019 and October 2022. CT dose index and dose-length product were used to calculate effective radiation dose. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated by standardized region-of-interest analysis. SNR and CNR dose ratios were calculated. Visual image quality was assessed by four independent readers on a five-point scale: 5, excellent or absent; 4, good or minimal; 3, moderate; 2, limited or substantial; and 1, poor or massive. Results Contrast-enhanced PCCT (n = 30) or DSCT (n = 84) was performed in 113 children (55 female and 58 male participants; median age, 66 days [IQR, 15-270]; median height, 56 cm [IQR, 52-67]; and median weight, 4.5 kg [IQR, 3.4-7.1]). A diagnostic image quality score of at least 3 was obtained in 29 of 30 (97%) with PCCT versus 65 of 84 (77%) with DSCT. Mean overall image quality ratings were higher for PCCT versus DSCT (4.17 vs 3.16, respectively; P < .001). SNR and CNR were higher for PCCT versus DSCT with SNR (46.3 ± 16.3 vs 29.9 ± 15.3, respectively; P = .007) and CNR (62.0 ± 50.3 vs 37.2 ± 20.8, respectively; P = .001). Mean effective radiation doses were similar for PCCT and DSCT (0.50 mSv vs 0.52 mSv; P = .47). Conclusion At a similar radiation dose, PCCT offers a higher SNR and CNR and thus better cardiovascular imaging quality than DSCT in children suspected of having cardiac heart defects. © RSNA, 2023.

1 October 2019 in Academic Radiology
Verified
Journal Article
Closed access
TDTimm Dirrichs
Timm Dirrichs
SSSimone Schrading
Simone Schrading
MGMatthias Gatz
Matthias Gatz
MTMarkus Tingart
Markus Tingart
CKChristiane K. Kuhl
Christiane K. Kuhl
VQValentin Quack
Valentin Quack

21 June 2024 in Academic Radiology
Verified
Journal Article
Open access
TDTimm Dirrichs
Timm Dirrichs
JSJörg Schröder
Jörg Schröder
MFMichael Frick
Michael Frick
MHMarc Huppertz
Marc Huppertz
RIRoman Iwa
Roman Iwa
CKChristiane K. Kuhl
Christiane K. Kuhl
Cardiovascular CT is required for planning transcatheter aortic valve implantation (TAVI). To compare image quality, suitability for TAVI planning, and radiation dose of photon-counting CT (PCCT) with that of dual-source CT (DSCT). Retrospective study on consecutive TAVI candidates with aortic valve stenosis who underwent contrast-enhanced aorto-ilio-femoral PCCT and/or DSCT between 01/2022 and 07/2023. Signal-to-noise (SNR) and contrast-to-noise ratio (CNR) were calculated by standardized ROI analysis. Image quality and suitability for TAVI planning were assessed by four independent expert readers (two cardiac radiologists, two cardiologists) on a 5-point-scale. CT dose index (CTDI) and dose-length-product (DLP) were used to calculate effective radiation dose (eRD). 300 patients (136 female, median age: 81 years, IQR: 76-84) underwent 302 CT examinations, with PCCT in 202, DSCT in 100; two patients underwent both. Although SNR and CNR were significantly lower in PCCT vs. DSCT images (33.0 ± 10.5 vs. 47.3 ± 16.4 and 47.3 ± 14.8 vs. 59.3 ± 21.9, P < .001, respectively), visual image quality was higher in PCCT vs. DSCT (4.8 vs. 3.3, P < .001), with moderate overall interreader agreement among radiologists and among cardiologists (κ = 0.60, respectively). Image quality was rated as "excellent" in 160/202 (79.2%) of PCCT vs. 5/100 (5%) of DSCT cases. Readers found images suitable to depict the aortic valve hinge points and to map the femoral access path in 99% of PCCT vs. 85% of DSCT (P < 0.01), with suitability ranked significantly higher in PCCT vs. DSCT (4.8 vs. 3.3, P < .001). Mean CTDI and DLP, and thus eRD, were significantly lower for PCCT vs. DSCT (22.4 vs. 62.9; 519.4 vs. 895.5, and 8.8 ± 4.5 mSv vs. 15.3 ± 5.8 mSv; all P < .001). PCCT improves image quality, effectively avoids non-diagnostic CT imaging for TAVI planning, and is associated with a lower radiation dose compared to state-of-the-art DSCT. Radiologists and cardiologists found PCCT images more suitable for TAVI planning.

1 June 2020 in Academic Radiology
Verified
Journal Article
Closed access
VQValentin Quack
Valentin Quack
MBMarcel Betsch
Marcel Betsch
JHJulian Hellmann
Julian Hellmann
JEJörg Eschweiler
Jörg Eschweiler
SSSimone Schrading
Simone Schrading
TDTimm Dirrichs
Timm Dirrichs