Thai Duy Nguyen

Thai Duy Nguyen

Auto-generated profile, based on publicly available information

Thai Duy Nguyen

Clinic for Pediatric & Congenital Heart Surgery, Children’s Heart Center, University Hospital RWTH Aachen, Germany

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2023 in Radiology
Verified
Journal Article
Closed access
TDTimm Dirrichs
Timm Dirrichs
ETEric Tietz
Eric Tietz
ARAndré Rüffer
André Rüffer
JHJens Hanten
Jens Hanten
TNThai Duy Nguyen
Thai Duy Nguyen
CKChristiane K. Kuhl
Christiane K. Kuhl
Background Photon-counting CT (PCCT) has been shown to improve cardiovascular CT imaging in adults. Data in neonates, infants, and young children under the age of 3 years are missing. Purpose To compare image quality and radiation dose of ultrahigh-pitch PCCT with that of ultrahigh-pitch dual-source CT (DSCT) in children suspected of having congenital heart defects. Materials and Methods This is a prospective analysis of existing clinical CT studies in children suspected of having congenital heart defects who underwent contrast-enhanced PCCT or DSCT in the heart and thoracic aorta between January 2019 and October 2022. CT dose index and dose-length product were used to calculate effective radiation dose. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated by standardized region-of-interest analysis. SNR and CNR dose ratios were calculated. Visual image quality was assessed by four independent readers on a five-point scale: 5, excellent or absent; 4, good or minimal; 3, moderate; 2, limited or substantial; and 1, poor or massive. Results Contrast-enhanced PCCT (n = 30) or DSCT (n = 84) was performed in 113 children (55 female and 58 male participants; median age, 66 days [IQR, 15-270]; median height, 56 cm [IQR, 52-67]; and median weight, 4.5 kg [IQR, 3.4-7.1]). A diagnostic image quality score of at least 3 was obtained in 29 of 30 (97%) with PCCT versus 65 of 84 (77%) with DSCT. Mean overall image quality ratings were higher for PCCT versus DSCT (4.17 vs 3.16, respectively; P < .001). SNR and CNR were higher for PCCT versus DSCT with SNR (46.3 ± 16.3 vs 29.9 ± 15.3, respectively; P = .007) and CNR (62.0 ± 50.3 vs 37.2 ± 20.8, respectively; P = .001). Mean effective radiation doses were similar for PCCT and DSCT (0.50 mSv vs 0.52 mSv; P = .47). Conclusion At a similar radiation dose, PCCT offers a higher SNR and CNR and thus better cardiovascular imaging quality than DSCT in children suspected of having cardiac heart defects. © RSNA, 2023.

17 November 2023 in Perfusion
Verified
Journal Article
Open access
TNThai Duy Nguyen
Thai Duy Nguyen
MMMohammed Morjan
Mohammed Morjan
KAKhaldoun Ali
Khaldoun Ali
IBIngo Breitenbach
Ingo Breitenbach
WHWolfgang Harringer
Wolfgang Harringer
AEAschraf El-Essawi
Aschraf El-Essawi
Introduction: Cardiac surgery in patients on chronic renal dialysis is associated with significant morbidity and mortality. Minimally invasive extracorporeal circuits (MiECC) have shown a positive impact on patient outcome in different high-risk populations. This retrospective study compares the outcome of these high-risk patients undergoing heart surgery either with a MiECC or a conventional extracorporeal circulation (CECC). Methods: This is a single-center experience including 131 consecutive dialysis dependent patients undergoing cardiac surgery between January 2006 and December 2016. A propensity score matching was employed leaving 30 matched cases in each group. Results: After propensity score matching the 30-day mortality was significantly lower in the MiECC group ( n = 3 (10%) vs n = 10 (33%) in the CECC group, p = .028). Further, intraoperative transfused units of packed red blood cells were lower in the MiECC group (1.4 ± 1.8 units vs 2.8 ± 1.7, p < .001). Conclusions: There are evident advantages to using MiECC in dialysis dependent patients, especially regarding mortality. These findings necessitate additional research in MiECC usage in high-risk populations.