Laccase, as a copper-containing polyphenol oxidase, primarily functions in the process of lignin, anthocyanin biosynthesis, and various abiotic/biotic stresses. In this study, forty-eight laccase members were identified in the eggplant genome. Only forty-two laccase genes from eggplant (SmLACs) were anchored unevenly in 12 chromosomes, the other six SmLACs were mapped on unanchored scaffolds. Phylogenetic analysis indicated that only twenty-five SmLACs were divided into six different groups on the basis of groups reported in Arabidopsis. Gene structure analysis revealed that the number of exons ranged from one to 13. Motif analysis revealed that SmLACs included six conserved motifs. In aspects of gene duplication analysis, twenty-one SmLACs were collinear with LAC genes from Arabidopsis, tomato or rice. Cis-regulatory elements analysis indicated many SmLACs may be involved in eggplant morphogenesis, flavonoid biosynthesis, diverse stresses and growth/development processes. Expression analysis further confirmed that a few SmLACs may function in vegetative and reproductive organs at different developmental stages and also in response to one or multiple stresses. This study would help to further understand and enrich the physiological function of the SmLAC gene family in eggplant, and may provide high-quality genetic resources for eggplant genetics and breeding.
9 July 2018 in Proceedings of the Institution of Mechanical Engineers, Part F: Journal of Rail and Rapid Transit
Optical sensors based on fiber Bragg gratings have become an important type of sensing element for strain measurements. In this study, fiber Bragg grating strain sensors and corresponding reference temperature sensors were integrated into a pantograph strip. The results of an online test indicated that the temperature of the pantograph strip impacting the strain measurement reaches about 80 ℃ while the vehicle was running. In addition, Fourier analysis showed that the energies of the temperature measurement signals dominated the relatively low-frequency band (less than 0.02 Hz), whereas the strain signals prevailed in the relatively high-frequency band. Thus, a novel method based on a digital filtering technique was proposed for temperature compensation in fiber Bragg grating sensor systems for monitoring the conditions in electrified pantograph–catenary systems. A Butterworth high-pass filter was designed to reject the temperature-related signal component with a stopband and to capture the real strain in the passband in frequency domain. To achieve this filtering, the cutoff frequencies and the filter order were calculated adaptively according to the frequency-domain characteristics of the measured temperature signal. With the designed filter, the temperature effect to the strain signals can be eliminated so that the strain can be estimated accurately. In comparison with the traditional temperature compensation technique, the proposed method is more effective in terms of estimating the real strain of the pantograph strip in practical applications. Compensated by the proposed method, the time-domain and frequency-domain analyses of the contact force denote the frequencies corresponding to the support span, and the dropper can be distinguished. Further, the first-order (4 Hz) and second-order (8.3 Hz) natural frequencies of the pantograph are visible in the measurements from catenary sections, which demonstrates the sufficiency and rationality of the proposed temperature compensation method for fiber Bragg grating sensor systems.
A fault diagnosis method of heating, ventilation, and air conditioning (HVAC) systems based on the ReliefF-recursive feature elimination based on cross validation-support vector machine (ReliefF-RFECV-SVM) combined model is proposed to enhance the diagnosis accuracy and efficiency. The method initially uses ReliefF to screen the original features, selecting those that account for 95% of the total weight. The recursive feature elimination based on cross validation (RFECV), based on a random forest classifier, is then applied to select the optimal feature subset according to diagnostic accuracy. Finally, a support vector machine (SVM) model is constructed for fault classification. The method is tested on seven typical faults of the ASHRAE 1043-RP water chiller dataset and three typical faults of an air-cooled self-built air conditioner simulation dataset. The results show that the ReliefF-RFECV-SVM method significantly reduces diagnosis time compared to SVM, shortening it by about 50% based on the ASHRAE 1043-RP dataset, while achieving an overall accuracy of 99.98%. Moreover, the proposed method achieves a comprehensive diagnosis accuracy of 99.97% on the self-built simulation dataset, with diagnosis time the reduced by about 65% compared to single SVM.
This paper describes an impact detection system using strain signals based on fibre optic sensors(FBG) for the real-time monitoring of the catenary system. The proposed detection system consists of three subsystems: a measuring system, a data processing and analysis system, and a status display and data access system. Because the strain signals obey the normal distribution, to monitor the catenary system in real time, a novel method that combines mobile standard deviation with the mobile Pauta criterion is proposed to distinguish real impact from the strain signal background. The use of this adaptive judging method reduces the misjudgment rate of impacts and improves the impact recognition accuracy. These impacts can be identified by the data analysis system, which provides impact location and their causes using the features of the catenary system. This method can simplify the detection system compared with the traditional location method. An application to a commercial metro line system indicated that the impacts on the catenary system were main caused by overlaps, expansion joints or steady arms, and were verified by correspondence with the floor plan of the catenary and manual inspection results. These results verified the reliability and effectiveness of the proposed impact detection system.
Heating, Ventilating, and Air Conditioning (HVAC) systems often suffer from unscheduled maintenance or abnormal shutdown due to the fault of their interior sensor system. Traditional fault diagnosis methods for HVAC sensor systems primarily focus on sensor fault diagnosis and isolation, lacking fault accommodation. Therefore, to realize effective sensor fault detection, identification, and accommodation (SFDIA), a method for HVAC SFDIA based on the soft sensor is proposed. First, a diagnosis soft sensor with multi-variable input is constructed to estimate the output of the physical sensor being diagnosed. The residual between the estimated value of the diagnosis soft sensor and the measurement of the physical sensor is used as an indicator of the sensor’s condition. If the residual exceeds the fault threshold, the sensor is diagnosed to be faulty. In order to maintain valid sensor output, an accommodation soft sensor is constructed using the historical normal value. The erroneous output of the faulty sensor is substituted by the estimated value from the accommodation soft sensor, thereby realizing sensor fault tolerance control. Experimental results demonstrate that the average false alarm rate for sensor fault diagnosis is 1.57% and the average fault diagnosis rate is 96.51%. The predictive mean absolute error (MAE) and root-mean-square error (RMSE) of the recovered soft sensors are 0.0525 and 0.0738, respectively. Thus, the soft sensors developed in this paper exhibit satisfying ability in HVAC SFDIA.
The condition of a catenary is significant to ensure a high current collection quality. Owing to the dynamic interaction between the pantograph and the catenary system, the vibration of the pantograph can be used to analyze the condition of the catenary system. Therefore, we developed a novel diagnosis system based on the correlation between catenary defects and pantograph vibration. The proposed system is capable of detecting the type and location of commonly encountered defects in rigid support catenary systems. Catenary positioning coefficient and enhanced sample entropy methods were proposed for the extraction of defect features, and subsequently, linear discriminate analysis was used to diagnose the type and location of the catenary defects. Finally, the proposed defect detection and diagnosis system was applied to a commercial metro line, and the results verified the reliability and effectiveness of this diagnosis system.