Background/Objectives: Chronic obstructive pulmonary disease (COPD) remains a condition with high morbidity, mortality, and misdiagnosis. The gold standard pulmonary function testing with spirometry has limited availability. This study seeks to test a novel diagnostic test based on auscultatory mapping of pulmonary dynamics. This NIH-funded study aimed to develop a COPD detection technology, using mobile phone auscultation, for situations in which spirometry is not available. Methods: This prospective study collected mobile phone auscultation data on patients presenting for spirometry and evaluation by a pulmonologist. All subjects had same-day or recent (less than 6 months) spirometry in one PFT laboratory. After informed consent, the subjects underwent respiratory auscultation using a selection of mobile phone brands. The auscultation methods included normal breathing observed at the left axillary site and egophony observed at the right supra clavicular fossa. The team created models from the recordings using Time Series Dynamics (TSD), proprietary software that uses computational nonlinear dynamics to characterize the respiratory biofluid dynamics implied by the acoustic data. Results: We enrolled a total of 108 patients (34.3% male), from 19 to 85 years of age (median 61 years). Among the patients, 64 (59.3%) subjects identified as White, 43 (39.8%) as Black, and 1 as Asian. Among the two cohorts with diverse comorbidities, 52 subjects had confirmed COPD and 56 did not. The cohorts differed significantly in age and body mass index, but not in race, number of comorbidities, or COPD assessment test scores. They had significant differences in forced expiratory volume in 1 s (FEV1), the FEV1/FVC (forced vital capacity) ratio, but not FVC. The recordings from the egophonic and axillary sites were initially modeled separately and then combined in a single composite model. The modeling produced excellent results with 90%+ AUC and sensitivity in both the test and train sets relative to the gold standard. Conclusions: Evidence suggests that a mobile phone auscultation device can accurately determine COPD diagnosis. In frontline applications where the availability of gold standard pulmonary function testing is limited, the device could improve the detection of COPD, a condition with significant over- and under-diagnosis. Future trials will investigate the ability of patients to self-record. Success would support remote COPD testing using transmitted telehealth recording data, bringing diagnosis to patients in underserved populations.
Immune checkpoint inhibitors (ICIs) have considerably changed the management of several malignancies. Although these agents transformed the scope of management in oncology and proved long-term efficacy, they have been associated with numerous autoimmune-related adverse events. We presented a case of a 61-year-old male with a history of non-small cell lung cancer (NSCLC) who presented with respiratory failure requiring mechanical ventilation. He was discharged with a working diagnosis of myasthenia gravis crisis secondary to the use of pembrolizumab. On further evaluation, he was found to possibly have pembrolizumab-induced myositis. He was treated with plasmapheresis, methylprednisolone, and rituximab and achieved significant improvement. Pembrolizumab, a monoclonal antibody, is an ICI that targets programmed death protein 1 (PD-1), thereby blocking the interaction between PD-1 and PDL-1, leading to an enhancement of T-cell mediated immune response against tumor cells. Pembrolizumab has been used to treat a variety of malignancies including melanoma, NSCLC, and other solid tumors. Though ICIs have revolutionized the field of oncology, they should be used with caution. ICIs can cause immune-related adverse events (irAEs), including myasthenia gravis and myositis. Diagnosing irAEs is challenging due to their nonspecific presentations and lack of antibody markers. Therefore, patients and clinicians should be aware of irAEs in order to initiate timely intervention.
Introduction: This case series describes a point of care ultrasound (POCUS) artifact involving the abdominal aorta of four standardized patients. The purpose of this case series is to highlight this artifact and maneuvers to discern pathology from normal. Methods: Permission was obtained for each case described in this series. POCUS images of the abdominal aorta in both sagittal and transverse were obtained in these four cases. The findings were reviewed and compared. Discussion: All four standardized patients were otherwise healthy, thin and female. The artifact was consistently a linear, hyperechoic structure within the lumen of the abdominal aorta in the sagittal plane. Conclusion: In each of these cases, the artifact disappeared on rotation of the probe from the sagittal plane to the transverse plane. Knowledge of this POCUS artifact and maneuvers to avoid it are important in both clinical and educational settings.