Ryan Close

Dr. Ryan Close


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 June 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
CGCaroline Gosser
Caroline Gosser
LDLuther Daniel
Luther Daniel
MHMartin Huecker
Martin Huecker
RCRodrigo Cavallazzi
Rodrigo Cavallazzi
HRHiram Rivas
Hiram Rivas
RCRyan Close
Ryan Close
Background/Objectives: Chronic obstructive pulmonary disease (COPD) remains a condition with high morbidity, mortality, and misdiagnosis. The gold standard pulmonary function testing with spirometry has limited availability. This study seeks to test a novel diagnostic test based on auscultatory mapping of pulmonary dynamics. This NIH-funded study aimed to develop a COPD detection technology, using mobile phone auscultation, for situations in which spirometry is not available. Methods: This prospective study collected mobile phone auscultation data on patients presenting for spirometry and evaluation by a pulmonologist. All subjects had same-day or recent (less than 6 months) spirometry in one PFT laboratory. After informed consent, the subjects underwent respiratory auscultation using a selection of mobile phone brands. The auscultation methods included normal breathing observed at the left axillary site and egophony observed at the right supra clavicular fossa. The team created models from the recordings using Time Series Dynamics (TSD), proprietary software that uses computational nonlinear dynamics to characterize the respiratory biofluid dynamics implied by the acoustic data. Results: We enrolled a total of 108 patients (34.3% male), from 19 to 85 years of age (median 61 years). Among the patients, 64 (59.3%) subjects identified as White, 43 (39.8%) as Black, and 1 as Asian. Among the two cohorts with diverse comorbidities, 52 subjects had confirmed COPD and 56 did not. The cohorts differed significantly in age and body mass index, but not in race, number of comorbidities, or COPD assessment test scores. They had significant differences in forced expiratory volume in 1 s (FEV1), the FEV1/FVC (forced vital capacity) ratio, but not FVC. The recordings from the egophonic and axillary sites were initially modeled separately and then combined in a single composite model. The modeling produced excellent results with 90%+ AUC and sensitivity in both the test and train sets relative to the gold standard. Conclusions: Evidence suggests that a mobile phone auscultation device can accurately determine COPD diagnosis. In frontline applications where the availability of gold standard pulmonary function testing is limited, the device could improve the detection of COPD, a condition with significant over- and under-diagnosis. Future trials will investigate the ability of patients to self-record. Success would support remote COPD testing using transmitted telehealth recording data, bringing diagnosis to patients in underserved populations.

4 March 2026 in Frontiers in Cardiovascular Medicine
Verified
Journal Article
Open access
PDF file
RCRyan Close
Ryan Close
GJGregory L. Judson
Gregory L. Judson
JZJacob Zhang
Jacob Zhang
KKKailey Kowalski
Kailey Kowalski
DMDestiny Martinez
Destiny Martinez
MHMartin Huecker
Martin Huecker
Background: The prevalence of valvular heart disease is increasing. Early detection remains poor as screening relies on front line detection of audible or symptomatic disease and confirmation requires specialized echocardiography. Methods: We conducted a single center, observational pilot study. Eligible subjects were stratified into groups based on echocardiographic findings. In addition to chart extraction of demographics, medical history, and echocardiographic parameters, each subject underwent three auscultation recordings that were analyzed via computational nonlinear dynamics to extract features and construct predictors without fitting or weighting. Predictors were used to create logistic regression binary classification models. Training and test set performance was reported for each model with a focus on area-under-the-curve and sensitivity as the primary benchmarks. Results: We analyzed the recordings of 248 subjects, median age 73 years, 43.6% female, 99% White. All recordings were chaotic and of low dimensionality. Personnel and subject collected recordings had a normalized mutual information entropy of 1.0, indicating they shared the same information and could be interchangeable for model development. Three models for aortic stenosis met predetermined metrics, with the best performing model reporting an AUC of 0.872 and a sensitivity of 0.923. Mitral regurgitation models were explored but limited by sample size. Conclusions: This study established the feasibility of two innovative approaches, by combining the sound recordings collected from unmodified mobile phones with analysis via nonlinear dynamics software. This work has the potential to improve valvular heart disease detection by overcoming barriers that remain for current standards of care and emerging artificial intelligence solutions.