Yafei Huang

Dr. Yafei Huang

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 August 2020 in IEEE Access
Verified
Journal Article
Open access
YHYafei Huang
Yafei Huang
MVMuhammad S. Virk
Muhammad S. Virk
Xingliang JiangXingliang Jiang
Xingliang Jiang
Ice accretion on insulators in cold regions is a serious and inevitable problem for power transmission lines, which may cause over-load and icing flashover accidents and can lead to wide power outage. In this research work, multiphase numerical simulations are carried out to investigate the effect of wind flow angle & velocity on the ice accretion of transmission line composite insulators. To verify the simulation results, lab-based icing tests are carried out in artificial climate chamber of Chongqing University. Results show that the change of wind flow angle has an obvious effect on both accreted ice shape and ice mass of insulators. When wind flow angle changes from 0° to 90° or - 90°, the ice mass increases before dropping sharply. Meanwhile, ice mass accretion on insulators with wind flow angle is more sensitive to the change of wind velocity. For V-shape insulator strings, the ice mass increased 47.22% in average compared to ordinary suspension insulators. The findings of this research can provide significant engineering reference for the design of transmission line in icing prone areas.

5 February 2024 in High Voltage
Verified
Journal Article
Open access
ZYZhongyi Yang
Zhongyi Yang
DLDongxiong Liu
Dongxiong Liu
XZXiangjun Zeng
Xiangjun Zeng
CFCaijin Fan
Caijin Fan
XYXin Yang
Xin Yang
YHYafei Huang
Yafei Huang
With the widespread application of composite insulators in transmission lines, exploring the accumulation mechanism of pollution particles on composite insulator surfaces is of importance to ensure the safe and steady operation of the power system. Addressing the current theoretical shortcomings, this study categorises the accumulation process of particles on the insulator surface into three stages, namely ‘spatial motion’, ‘surface collision’, and ‘surface motion’. The motion and rotation velocities in a multi‐physics field are calculated in the spatial motion stage. In the surface collision stage, a parameter called ‘neck height’ is introduced to determine the optimum mechanics theory, and the normal deposition criterion is established. For the surface motion stage, the sliding displacement and rolling displacement on the surface are calculated based on the rotation speed of the particles. A dynamic pollution accumulation model of the composite insulator is established based on the normal deposition criterion and tangential displacement. Finally, numerical simulations are performed by using the finite element method. Simulation results show that the proposed model agrees with the actual insulator pollution accumulation, and the deposition model is still applicable for various types of composite insulators operating in different applied voltages. The deposition probability of particles increases with the increasing particle size. In the surface motion stage, particle displacement increases with particle size and wind velocity.

1 May 2026 in Physics of Fluids
Verified
Journal Article
Closed access
PDF file
YHYafei Huang
Yafei Huang
JWJiake Wang
Jiake Wang
XYXin Yang
Xin Yang
ZYZhongyi Yang
Zhongyi Yang
TTTian Tan
Tian Tan
Mixed-phase icing, characterized by the coexistence of supercooled water droplet and ice crystal, is a critical issue to the operation of wind turbines. This study is based on the Euler–Euler multiphase flow framework, combined with an extended Messinger thermodynamic model and an ice sticking–erosion model, to establish a three-dimensional rotating mixed-phase icing model of full-scale wind turbine blades. The results reveal that the mixed-phase icing model achieves an accuracy of 73.4% compared to experimental data, while the single supercooled droplet icing model reaches 91.7% accuracy. At the total water content of 1.0 g/m3, with the liquid water content to the ice water content ratio of 0.5/0.5 or lower, streamlined ice shapes are observed at the 0.95R blade section, where ice crystal sticking predominantly controls icing. In contrast, when the ratio exceeds 0.5/0.5, the ice develops an angular morphology, which suggests that water film dynamics primarily control the icing process. Additionally, droplet median volume diameter (MVD) significantly influences mixed-phase icing behavior, with sticking effects showing a positive correlation with droplet MVD. These findings provide valuable insights for predicting icing characteristics on three-dimensional rotating wind turbine blades.

27 July 2026 in Sensors
Verified
Journal Article
Open access
PDF file
SHsheng Han
sheng Han
JDJialong Dong
Jialong Dong
YHYafei Huang
Yafei Huang
BZBaifu Zhang
Baifu Zhang
Emissivity is a critical parameter in infrared temperature measurement and varies significantly among different materials. Infrared thermography has been widely used for the inspection of substation equipment. However, substations contain a large number of devices with complex structures, making it impractical to assign a separate emissivity value to each device or component. This limitation can significantly affect temperature measurement accuracy. To address this issue, this paper proposes an intelligent multi-emissivity temperature correction method for infrared images of substation equipment. First, a temperature–emissivity correction function is established. Then, a total of 2189 infrared images of substation equipment are collected, and the main equipment components are annotated at the pixel level. Subsequently, an equipment component segmentation model based on DeepLabv3+ is trained. Finally, different emissivity values are assigned to different component regions for temperature correction, and corrected infrared pseudo-color images are regenerated. In the experiment, the temperature values before and after correction are compared with thermocouple measurements. In the present validation experiment, the average deviation between the corrected infrared temperature and the thermocouple measurement was reduced by 79.2% compared with that before correction.

18 August 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YHYafei Huang
Yafei Huang
Xingliang JiangXingliang Jiang
Xingliang Jiang
JJJiayi Jin
Jiayi Jin
ZYZhongyi Yang
Zhongyi Yang
This paper proposes a rotating test method to address the limitations of high costs and the inability to replicate high-speed multiphase environments in icing wind tunnels and artificial climate chambers. The method simulates high-speed multiphase in an enclosed space using relative motion and duct regulation at a lower cost. Using the FQJG2-30/16-400 type roof insulator, the Eulerian–Eulerian and CFD (computational fluid dynamics) method was employed to compare the proposed rotating method with traditional linear airflow tests in wind–sand erosion and high-speed icing experiments. Results show maximum differences of 3.23% in the collision rate and 4.34% in the icing mass, indicating good consistency. Validation experiments in an artificial climate chamber further confirmed the feasibility of the rotating test method, with icing mass differences within 5–8%. This study provides a cost-effective approach for high-speed testing in multiphase environments.

20 April 2026 in Energies
Verified
Journal Article
Open access
PDF file
TTTian Tan
Tian Tan
HPHuajian Peng
Huajian Peng
XYXin Yang
Xin Yang
JLJiaxi Liu
Jiaxi Liu
MLMingzhe Li
Mingzhe Li
YHYafei Huang
Yafei Huang
Tree contact discharge is a key contributing factor to wildfires caused by medium-voltage insulated conductors. Prolonged abrasion of the insulation layer by branches gradually creates weak points in the insulation. When subjected to lightning strikes, these areas are prone to forming lightning-induced pinholes, which can subsequently trigger partial discharge and even ignition. This study systematically investigates the discharge-induced ignition mechanism for 10 kV overhead insulated conductors in tree contact scenarios by establishing an experimental platform integrated with high-speed imaging, ultraviolet detection, and simulation methods. Three types of typical defects were set up in the experiments: complete insulation abrasion, lightning puncture holes accompanied by localized abrasion, and lightning puncture holes without abrasion. The development process and characteristics of different discharge forms were observed and analyzed. The results indicate that the tree contact discharge ignition mechanism can be categorized into two types: thermal accumulation and direct arcing. The former occurs when insulation abrasion or composite defects exist, where sustained partial discharge or a high-resistance current leads to gradual heat accumulation, resulting in an ignition delay lasting tens of seconds. The latter occurs when only small defects such as lightning puncture holes exist in the insulation layer. A concentrated arc forms due to gap breakdown under high voltage, leading to a millisecond-level ignition process. The study found that different discharge forms produce significantly distinct ablation and carbonization patterns on both the insulation layer and the branch surface, reflecting differences in energy transfer pathways. Simulation analysis further indicated that the thickness of the insulation layer affects the electric field distribution in the tree contact gap, with the initial discharge field strength decreasing as the thickness increases. This study provides experimental evidence and classification guidance for tree contact fault monitoring, insulation condition assessment, and wildfire prevention and control in medium-voltage distribution networks.