Ke Ma

Dr. Ke Ma

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 January 2023 in Chemical Communications
Verified
Journal Article
Closed access
PDF file
LOLing Ouyang
Ling Ouyang
XFXiaoya Fan
Xiaoya Fan
ZLZerong Li
Zerong Li
He XunHe Xun
He Xun
SSShengjun Sun
Shengjun Sun
Xuping SunXuping Sun
Xuping Sun
A Cu nanoparticle-decorated TiO2 nanobelt array on a titanium plate acts as a catalyst for NH3 electrosynthesis via NO2− reduction, attaining an NH3 yield of 760.5 μmol h−1 cm−2 (237.7 μmol h−1 mgcat.−1) and a high Faradaic efficiency of 95.3%.

5 April 2023 in Chemical Communications
Verified
Journal Article
Closed access
PDF file
PHPeiji Hu
Peiji Hu
SHSongjie Hu
Songjie Hu
HDHongting Du
Hongting Du
QLQian Liu
Qian Liu
HGHaoran Guo
Haoran Guo
TLTingshuai Li
Tingshuai Li
SmCoO3nanofibers achieve a large NH3yield of 14.4 mg h−1mgcat.−1and a high faradaic efficiency of 81.3% at −1.0 Vvs. RHE in 0.1 M PBS with 0.1 M NO3−.

20 December 2022 in Journal of Materials Chemistry A
Verified
Journal Article
Closed access
PDF file
JLJie Liang
Jie Liang
Longcheng ZhangLongcheng Zhang
Longcheng Zhang
He XunHe Xun
He Xun
Yan WangYan Wang
Yan Wang
YLYongsong Luo
Yongsong Luo
CTChengwu Tang
Chengwu Tang
Under ambient conditions, using low concentration NO (1%), ultrahigh nitrate formation rates in a two-electrode system can be achievedviathe eCOR-NOOR. The structure changes of electrode materials under real reaction conditions are revealed.

22 March 2024 in Eye
Verified
Journal Article
Closed access
PDF file
QWQi Wan
Qi Wan
PHPeiyuan He
Peiyuan He
RWRan Wei
Ran Wei
KMKe Ma
Ke Ma
HYHongbo Yin
Hongbo Yin
YDYingping Deng
Yingping Deng

17 March 2025 in Graefe's Archive for Clinical and Experimental Ophthalmology
Verified
Journal Article
Closed access
PDF file
QWQi Wan
Qi Wan
QWQiong Wang
Qiong Wang
RWRan Wei
Ran Wei
JTJing Tang
Jing Tang
HYHongbo Yin
Hongbo Yin
KMKe Ma
Ke Ma

30 December 2024 in Annals of Medicine
Verified
Journal Article
Open access
WQWan Qi
Wan Qi
LCLi Chen
Li Chen
PHPeiyuan He
Peiyuan He
RWRan Wei
Ran Wei
KMKe Ma
Ke Ma
YDYingping Deng
Yingping Deng
The objective of the investigation is to examine the long term efficacy, safety, and predictability of ICL-V4c implantation for high and super-high myopic patients in order to provide reliable guidance for the selection of refractive surgical procedures. We reviewed 125 eyes from 64 patients who implanted ICL-V4c at the Refractive Surgery Center of West China Hospital in Chengdu, China, between May 2015 and January 2017. These eyes were divided into two groups based on their preoperative spherical equivalent (SE) degree: high myopia (≥ −10D) and super-high myopia groups (< −10D). We followed up with the patients over 5 years and evaluated several parameters, including uncorrected visual acuity (UDVA), corrected visual acuity (CDVA), axial length (AL), refractive error, endothelial cell density (ECD), intraocular pressure (IOP), white-to-white distance (WTW), and vault. The efficacy indices of ICL-V4c implantation in high and super-high myopia groups were 0.91 ± 0.23 and 0.80 ± 0.25, respectively at 5 years after operation. Compared to high myopia group, the efficacy index of super-high myopia was obviously decreased (p = 0.020) and the △AL of super-high myopia was significantly increased (p = 0.001). The mean safety indices were 1.10 ± 0.15 and 1.10 ± 0.21 respectively in high and super-high myopia groups (p = 0.850). At the 5-year mark, 11.67% vs 20.00% (High vs Super-high) of eyes were within ±0.50 D (Spherical Equivalent), and 75.00% vs 70.77% (High vs Super-high) of eyes were within ±2.00 D. No significant difference of ECD was found in the high (2823.45 ± 274.75 cells/mm2) and super-high myopia (2856.71 ± 323.53cells/mm2) at the visit of 5 years. Compared to baseline, we observed a significant increase in IOP at the 1-week follow-up, which decreased significantly at the one-month visit. Furthermore, there was a significant difference of vault between the high and super-high groups at 1-month (p = 0.042) and 5-year (p = 0.002) after surgery. ICL-V4c implantation is effective, safe, and stable for correcting high and super-high myopia. However, ophthalmologists need to be aware of the potential for greater myopia regression in super-high myopic patients, as well as the increase in axial length and associated fundus complications.