This paper presents a study on the application of the Markov Model (MM) to determine the transformer population states based on Health Index (HI). In total, 3195 oil samples from 373 transformers ranging in age from 1 to 25 years were analyzed. First, the HI of transformers was computed based on yearly individual oil condition monitoring data that consisted of oil quality, dissolved gases, and furanic compounds. Next, the average HI for each age was computed and the transition probabilities were obtained based on a nonlinear optimization technique. Finally, the future deterioration performance curve of the transformers was determined based on the MM chain algorithm. It was found that the MM can be used to predict the future transformers condition states. The chi-squared goodness-of-fit analysis revealed that the predicted HI for the transformer population obtained based on MM agrees with the average computed HI along the years, and the average error is 3.59%.

14 August 2018 in Energies
Verified
Journal Article
Open access
PDF file
ASAmran Mohd Selva
Amran Mohd Selva
NANorhafiz Azis
Norhafiz Azis
MYMuhammad Sharil Yahaya
Muhammad Sharil Yahaya
MKMohd Zainal Abidin Ab. Kadir
Mohd Zainal Abidin Ab. Kadir
JJJasronita Jasni
Jasronita Jasni
MTMohd Aizam Talib
Mohd Aizam Talib
This paper presents a study to estimate individual condition parameters of the transformer population based on Markov Model (MM). The condition parameters under study were hydrogen (H2), methane (CH4), acetylene (C2H2), ethylene (C2H4), ethane (C2H6), carbon monoxide (CO), carbon dioxide (CO2), dielectric breakdown voltage, interfacial tension, colour, acidity, water content, and 2-furfuraldehyde (2-FAL). First, the individual condition parameter of the transformer population was ranked and sorted based on recommended limits as per IEEE Std. C57. 104-2008 and IEEE Std. C57.106-2015. Next, the mean for each of the condition parameters was computed and the transition probabilities for each condition parameters were obtained based on non-linear optimization technique. Next, the future states probability distribution was computed based on the MM prediction model. Chi-square test and percentage of absolute error analysis were carried out to find the goodness-of-fit between predicted and computed condition parameters. It is found that estimation for majority of the individual condition parameter of the transformer population can be carried out by MM. The Chi-square test reveals that apart from CH4 and C2H4, the condition parameters are outside the rejection region that indicates agreement between predicted and computed values. It is also observed that the lowest and highest percentages of differences between predicted and computed values of all the condition parameters are 81.46% and 98.52%, respectively.

18 March 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ASAmran Mohd Selva
Amran Mohd Selva
NANorhafiz Azis
Norhafiz Azis
NSNor Shafiqin Shariffudin
Nor Shafiqin Shariffudin
MKMohd Zainal Abidin Ab. Kadir
Mohd Zainal Abidin Ab. Kadir
JJJasronita Jasni
Jasronita Jasni
MTMohd Aizam Talib
Mohd Aizam Talib
In this study, statistical distribution model (SDM) is used to predict the health index (HI) of transformers by utilizing the condition parameters data from dissolved gas analysis (DGA), oil quality analysis (OQA), and furanic compound analysis (FCA), respectively. First, the individual condition parameters data were categorized based on transformer age from year 1 to 15. Next, the individual condition parameters data for every age were fitted while using a probability plot to find the representative distribution models. The distribution parameters were calculated based on 95% confidence level and extrapolated from year 16 to 25 through representative fitting models. The individual condition parameters data within the period were later calculated based on the estimated distribution parameters through the inverse cumulative distribution function (ICDF) of the selected distribution models. The predicted HI was then determined based on the conventional scoring method. The Chi-square test for statistical hypothesis reveals that the predicted HI for the transformer data is quite close to the calculated HI. The average percentage of absolute error is 2.7%. The HI that is predicted based on SDM yields 97.83% accuracy for the transformer data.

25 September 2018 in Sustainability
Verified
Journal Article
Open access
PDF file
MYMuhammad Sharil Yahaya
Muhammad Sharil Yahaya
NANorhafiz Azis
Norhafiz Azis
ASAmran Mohd Selva
Amran Mohd Selva
MKMohd Zainal Abidin Ab. Kadir
Mohd Zainal Abidin Ab. Kadir
JJJasronita Jasni
Jasronita Jasni
MTMohd Aizam Talib
Mohd Aizam Talib
This paper presents an investigation of the condition state distribution and performance condition curve of the transformer population under different pre-determined maintenance repair rates based on the Markov Prediction Model (MPM). In total, 3195 oil samples from 373 transformers with an age between one and 25 years were tested. The previously computed Health Index (HI) prediction model of the transformer population based on MPM utilizing the nonlinear minimization technique was employed in this study. The transition probabilities for each of the states were updated based on 10%, 20% and 30% pre-determined maintenance repair rates for the sensitivity study. Next, the HI state distribution and performance condition curve were analyzed based on the Markov chain algorithm. Based on the case study, it is found that the pre-determined maintenance repair rates can affect the HI state distribution and improve the performance condition curve. The 30% pre-determined maintenance repair rate gives the highest impact, especially for the transformer population at state 4 (poor). Overall, the average percentage of change for all HI state distributions is 16.48%. A clear improvement of HI state distribution is found at state 4 (poor) where the highest percentage can be up to 63.25%.

2 August 2018 in Energies
Verified
Journal Article
Open access
PDF file
MYMuhammad Sharil Yahaya
Muhammad Sharil Yahaya
NANorhafiz Azis
Norhafiz Azis
ASAmran Mohd Selva
Amran Mohd Selva
MKMohd Zainal Abidin Ab. Kadir
Mohd Zainal Abidin Ab. Kadir
JJJasronita Jasni
Jasronita Jasni
Young Zaidey Yang GhazaliYoung Zaidey Yang Ghazali
Young Zaidey Yang Ghazali
In this paper, a maintenance cost study of transformers based on the Markov Model (MM) utilizing the Health Index (HI) is presented. In total, 120 distribution transformers of oil type (33/11 kV and 30 MVA) are examined. The HI is computed based on condition assessment data. Based on the HI, the transformers are arranged according to its corresponding states, and the transition probabilities are determined based on frequency of a transition approach utilizing the transformer transition states for the year 2013/2014 and 2012/2013. The future states of transformers are determined based on the MM chain algorithm. Finally, the maintenance costs are estimated based on future-state distribution probabilities according to the proposed maintenance policy model. The study shows that the deterioration states of the transformer population for the year 2015 can be predicted by MM based on the transformer transition states for the year 2013/2014 and 2012/2013. Analysis on the relationship between the predicted and actual computed numbers of transformers reveals that all transformer states are still within the 95% prediction interval. There is a 90% probability that the transformer population will reach State 1 after 76 years and 69 years based on the transformer transition states for the year 2013/2014 and 2012/2013. Based on the probability-state distributions, it is found that the total maintenance cost increases gradually from Ringgit Malaysia (RM) 5.94 million to RM 39.09 million based on transformer transition states for the year 2013/2014 and RM 37.56 million for the year 2012/2013 within the 20 years prediction interval, respectively.

1 October 2012 in Procedia - Social and Behavioral Sciences
Verified
Journal Article
Open access
PDF file
MYMuhammad Sharil Yahaya
Muhammad Sharil Yahaya
ANA. Noordin
A. Noordin
SAS. Ahmad
S. Ahmad
MSM. R. Mohamad Sapiee
M. R. Mohamad Sapiee
In line with industrial development which is growing rapidly in Malaysia, engineering technology program is likely to be introduced in Malaysia education system at higher level. Towards developing the electrical engineering technology program and designing a curriculum structure in Universiti Teknikal Malaysia Melaka (UTeM), a market survey has been conducted to gather opinion from industries on the relevant subjects, duration of training required and also the career opportunity. The market research survey was conducted by the Committee of Development for Engineering Technology, UTeM in 2011. A total of 110 questionnaires were distributed to local and foreign companies throughout Malaysia. The scope of the market survey covered the common understanding of the concept of Engineering Technologist, requirements from industry perspective, the relevant focus areas as well as perceptions towards the program. As a result, the market research shows that there is a demand for degree programs in Electrical Engineering Technology.