Chest X-ray (CXR) is a low-cost medical imaging technique. It is a common procedure for the identification of many respiratory diseases compared to MRI, CT, and PET scans. This paper presents the use of generative adversarial networks (GAN) to perform the task of lung segmentation on a given CXR. GANs are popular to generate realistic data by learning the mapping from one domain to another. In our work, the generator of the GAN is trained to generate a segmented mask of a given input CXR. The discriminator distinguishes between a ground truth and the generated mask, and updates the generator through the adversarial loss measure. The objective is to generate masks for the input CXR, which are as realistic as possible compared to the ground truth masks. The model is trained and evaluated using four different discriminators referred to as D1, D2, D3 and D4 respectively. Experimental results on three different CXR datasets reveal that the proposed model is able to achieve a dice-score of 0.9740, and IOU score of 0.943, which are better than other reported state-of-the art results.
Purpose: Respiratory rate can provide auxiliary information on the physiological changes within the human body, such as physical and emotional stress. In a clinical setup, the abnormal respiratory rate can be indicative of the deterioration of the patient's condition. Most of the existing algorithms for the estimation of respiratory rate using photoplethysmography (PPG) are sensitive to external noise and may require the selection of certain algorithm-specific parameters, through the trial-and-error method. Methods: This paper proposes a new algorithm to estimate the respiratory rate using a photoplethysmography sensor signal for health monitoring. The algorithm is resistant to signal loss and can handle low-quality signals from the sensor. It combines selective windowing, preprocessing and signal conditioning, modified Welch filtering and postprocessing to achieve high accuracy and robustness to noise. Results: The Mean Absolute Error and the Root Mean Square Error of the proposed algorithm, with the optimal signal window size, are determined to be 2.05 breaths count per minute and 2.47 breaths count per minute, respectively, when tested on a publicly available dataset. These results present a significant improvement in accuracy over previously reported methods. The proposed algorithm achieved comparable results to the existing algorithms in the literature on the BIDMC dataset (containing data of 53 subjects, each recorded for 8 min) for other signal window sizes. Conclusion: The results endorse that integration of the proposed algorithm to a commercially available pulse oximetry device would expand its functionality from the measurement of oxygen saturation level and heart rate to the continuous measurement of the respiratory rate with good efficiency at home and in a clinical setting.
Stress is known as a silent killer that contributes to several life-threatening health conditions such as high blood pressure, heart disease, and diabetes. The current standard for stress evaluation is based on self-reported questionnaires and standardized stress scores. There is no gold standard to independently evaluate stress levels despite the availability of numerous biophysiological stress indicators. With an increasing interest in wearable health monitoring in recent years, several studies have explored the potential of various biophysiological indicators of stress for this purpose. However, there is no clear understanding of the relative sensitivity and specificity of these stress-related biophysiological indicators of stress in the literature. Hence this study aims to perform statistical analysis and classification modelling of biophysiological data gathered from healthy individuals, undergoing various induced emotional states, and to assess the relative sensitivity and specificity of common biophysiological indicators of stress. In this paper, several frequently used key indicators of stress, such as heart rate, respiratory rate, skin conductance, RR interval, heart rate variability in the electrocardiogram, and muscle activation measured by electromyography, are evaluated based on a detailed statistical analysis of the data gathered from an already existing, publicly available WESAD (Wearable Stress and Affect Detection) dataset. Respiratory rate and heart rate were the two best features for distinguishing between stressed and unstressed states.
Physiological pressure measurement is one of the most common applications of sensors in healthcare. Particularly, continuous pressure monitoring provides key information for early diagnosis, patient-specific treatment, and preventive healthcare. This paper presents a thin-film flexible wireless pressure sensor for continuous pressure measurement in a wide range of medical applications but mainly focused on interface pressure monitoring during compression therapy to treat venous insufficiency. The sensor is based on a pressure-dependent capacitor () and printed inductive coil () that form an inductor-capacitor (LC) resonant circuit. A matched reader coil provides an excellent coupling at the fundamental resonance frequency of the sensor. Considering varying requirements of venous ulceration, two versions of the sensor, with different sizes, were finalized after design parameter optimization and fabricated using a cost-effective and simple etching method. A test setup consisting of a glass pressure chamber and a vacuum pump was developed to test and characterize the response of the sensors. Both sensors were tested for a narrow range (0–100 mmHg) and a wide range (0–300 mmHg) to cover most of the physiological pressure measurement applications. Both sensors showed good linearity with high sensitivity in the lower pressure range <100 mmHg, providing a wireless monitoring platform for compression therapy in venous ulceration.