Anthony Jones

Mr. Anthony Jones

orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

14 April 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
RSReza Saatchi
Reza Saatchi
AHAlan Holloway
Alan Holloway
JTJonathan Travis
Jonathan Travis
HEHeather Elphick
Heather Elphick
WDWill Daw
Will Daw
RERobert L. Evans
Robert L. Evans
Respiration rate (RR) is an important vital sign for early detection of health deterioration in critically unwell patients. Its measurement is currently subjective, relying on visual counting of chest movements. The design of a new RR measurement device utilising a self-heating thermistor as its sensing element is described. The thermistor is situated in a hand-held air chamber with a funnel attachment that detects respiratory airflow up to 30 cm from the face. The exhaled respiratory airflow reduces the temperature of the thermistor, and its temperature recovers during inhalation. A microcontroller provides signal processing while its display screen shows the respiratory signal and RR. The device has been evaluated on 27 healthy adult volunteers, mean age 32.8 years (standard deviation 8.6 years). The RR readings from the device were compared with the visual counting of chest movements and the contact method of inductance plethysmography implemented using a commercial device (SOMNOtouch™ RESP). The RR readings from the new device and SOMNOtouch™ RESP, averaged across the 27 participants, were 14.6 breaths per minute (bpm) and 14.0 bpm respectively. The device has a robust operation, is easy to use and gives an objective measure of RR in a non-contact manner.

1 June 2018
Verified
Conference Paper
Closed access
HXHaohua Xiu
Haohua Xiu
TXTao Xu
Tao Xu
AJAnthony Jones
Anthony Jones
Guowu WeiGuowu Wei
Guowu Wei
LRLei Ren
Lei Ren
Jian S DaiJian S Dai
Jian S Dai
This paper for the first time presents a deployable quadrotor based on a deployable hexahedral mechanism. Structure design of the proposed deployable quadrotor is introduced and mobility and kinematics of the associated deployable hexahedral mechanism are briefly addressed. Then kinematics and dynamics of the proposed deployable quadrotor are established and the results are verified through numerical simulations, leading to the demonstration of performance and manoeuvrability of the proposed quadrotor. This paper hence also provides insight into the integration of deployable mechanisms into the development of quadrotors for wider applications.

1 April 2000 in IFAC Proceedings Volumes
Verified
Journal Article
Closed access
Paulo Moura OliveiraPaulo Moura Oliveira
Paulo Moura Oliveira
AJAnthony Jones
Anthony Jones

9 June 2025 in Technologies
Verified
Journal Article
Open access
PDF file
RSReza Saatchi
Reza Saatchi
AHAlan Holloway
Alan Holloway
JTJohnathan Travis
Johnathan Travis
HEHeather Elphick
Heather Elphick
WDWill Daw
Will Daw
RERobert L. Evans
Robert L. Evans
The respiration rate (RR) is an important vital sign for early detection of health deterioration in critically unwell patients. Its current measurement has limitations, relying on visual counting of chest movements. The design of a new RR measurement device utilizing a self-heating thermistor is described. The thermistor is integrated into a hand-held air chamber with a funnel attachment to sensitively detect respiratory airflow. The exhaled respiratory airflow reduces the temperature of the thermistor that is kept at a preset temperature, and its temperature recovers during inhalation. A microcontroller provides signal processing, while its display screen shows the respiratory signal and RR. The device was evaluated on 27 healthy adult volunteers, with a mean age of 32.8 years (standard deviation of 8.6 years). The RR measurements from the device were compared with the visual counting of chest movements, and the contact method of inductance plethysmography that was implemented using a commercial device (SOMNOtouch™ RESP). Statistical analysis, e.g., correlations were performed. The RR measurements from the new device and SOMNOtouch™ RESP, averaged across the 27 participants, were 14.6 breaths per minute (bpm) and 14.0 bpm, respectively. The device has a robust operation, is easy to use, and provides an objective measure of the RR in a noncontact manner.