The development of an implantable system designed to deliver drug doses in a controlled manner over an extended time period is reported. Key performance parameters are the physical size, the power consumption and also the ability to perform wireless communications to enable the system to be externally controlled and interrogated. The system has been designed to facilitate wireless power transfer, which is very important for miniaturisation as it removes the need for a battery.
Current approaches to molecular diagnostics rely heavily on PCR amplification and optical detection methods which have restrictions when applied to point of care (POC) applications. Herein we describe the development of a label-free and amplification-free method of pathogen detection applied to Escherichia coli which overcomes the bottleneck of complex sample preparation and has the potential to be implemented as a rapid, cost effective test suitable for point of care use. Ribosomal RNA is naturally amplified in bacterial cells, which makes it a promising target for sensitive detection without the necessity for prior in vitro amplification. Using fluorescent microarray methods with rRNA targets from a range of pathogens, an optimal probe was selected from a pool of probe candidates identified in silico. The specificity of probes was investigated on DNA microarray using fluorescently labeled 16S rRNA target. The probe yielding highest specificity performance was evaluated in terms of sensitivity and a LOD of 20 pM was achieved on fluorescent glass microarray. This probe was transferred to an EIS end point format and specificity which correlated to microarray data was demonstrated. Excellent sensitivity was facilitated by the use of uncharged PNA probes and large 16S rRNA target and investigations resulted in an LOD of 50 pM. An alternative kinetic EIS assay format was demonstrated with which rRNA could be detected in a species specific manner within 10-40min at room temperature without wash steps.
An MRSA assay requiring neither labeling nor amplification of target DNA has been developed. Sequence specific binding of fragments of bacterial genomic DNA is detected at femtomolar concentrations using electrochemical impedance spectroscopy (EIS). This has been achieved using systematic optimisation of probe chemistry (PNA self-assembled monolayer film on gold electrode), electrode film structure (the size and nature of the chemical spacer) and DNA fragmentation, as these are found to play an important role in assay performance. These sensitivity improvements allow the elimination of the PCR step and DNA labeling and facilitate the development of a simple and rapid point of care test for MRSA. Assay performance is then evaluated and specific direct detection of the MRSA diagnostic mecA gene from genomic DNA, extracted directly from bacteria without further treatment is demonstrated for bacteria spiked into saline (106 cells per mL) on gold macrodisc electrodes and into human wound fluid (104 cells per mL) on screen printed gold electrodes. The latter detection level is particularly relevant to clinical requirements and point of care testing where the general threshold for considering a wound to be infected is 105 cells per mL. By eliminating the PCR step typically employed in nucleic acid assays, using screen printed electrodes and achieving sequence specific discrimination under ambient conditions, the test is extremely simple to design and engineer. In combination with a time to result of a few minutes this means the assay is well placed for use in point of care testing.
Quantum dot (QD) labeling combined with fluorescence lifetime imaging microscopy is proposed as a powerful transduction technique for the detection of DNA hybridization events. Fluorescence lifetime analysis of DNA microarray spots of hybridized QD labeled target indicated a characteristic lifetime value of 18.8 ns, compared to 13.3 ns obtained for spots of free QD solution, revealing that QD labels are sensitive to the spot microenvironment. Additionally, time gated detection was shown to improve the microarray image contrast ratio by 1.8, achieving femtomolar target sensitivity. Finally, lifetime multiplexing based on Qdot525 and Alexa430 was demonstrated using a single excitation-detection readout channel.