A 14 T conduction-cooled superconducting magnet with a clear cold bore of 50 mm in diameter is designed and fabricated for a physical property measurement system. The magnet is built with six Nb 3 Sn coils and five NbTi coils arranged coaxially. To reliably protect the 14 T magnet, a passive quench protection scheme is developed, including a novel coil subdivision method and heater network design. The novel coil subdivision method mixes a NbTi coil and an Nb 3 Sn coil into the same subdivision to reduce the hot-spot temperature of the Nb 3 Sn coil. Different heaters parameters are compared and analyzed to obtain a lower hot-spot temperature. In addition, an efficient way of raising the ratio of copper to superconductor in the superconducting wires is used to reduce the hot-spot temperature of the Nb 3 Sn coils in the low magnetic field region. An in-house quench simulation code in MATLAB, including a finite difference method for the Nb 3 Sn coils in the low magnetic field region and a quench ellipsoid propagation model for the other coils, has been developed. This article describes the details of the passive quench protection scheme and presents the quench simulation results.
25 December 2023 in IEEE Transactions on Applied Superconductivity
As an essential system component of a magnetic resonance imaging (MRI) instrument, the magnet offers strong and uniform magnetic field intensity, which is critical for achieving the desired image resolution. This work presents the design, fabrication, and measurement of a 3 T cryogen-free superconducting magnet for animal MRI applications. The magnet presented excellent stability, maintaining a field variation of just 0.01 ppm per hour at full strength. After passive shimming, the magnetic field homogeneity achieved around 32 ppm over an imaging sphere with a diameter of 160 mm. The success of this reliable magnet technology paves the way for its adoption in future whole-body human MRI systems.
5 December 2014 in IEEE Transactions on Applied Superconductivity
There are very strong requirements for the magnets with very high magnetic field for experimental facilities used in the new generations of special material processing devices. A high magnetic field superconducting magnet has been designed with the center field of 8 T, warm bore of 100 mm, and warm split-gap of 100 mm. The maximum magnetic field in the superconducting winding is about 11 T. Two GM cryocoolers are employed to cool down the system. The magnet consists of two high temperature superconducting coils with commercially available Bi-2223 tapes and six NbTi superconducting coils. There is very strong attractive force between the split-pairs coils. The design, fabrication and test of the superconducting magnet are reported in this paper.
3 November 2011 in IEEE Transactions on Applied Superconductivity
A gas-gap thermal switch is developed to reduce the cool-down time of conduction cooled superconducting magnet. The main feature of the thermal switch is that it is sealed naturally at atmospheric environment in comparison with other gas-gap thermal switch, thereby it is much greater convenient during assembly. The switch is a closed container that contains several pairs of concentric tube-fins arranged in staggered way and it is located between first stage and second stage of GM cryocooler. At the beginning of the cool down, the thermal switch can transfer power from the first stage with the higher refrigeration capacity to the magnet. So the cool-down rate of the magnet is increased. To check the performance of the switch, we use a superconducting magnet for gyrotron whose weight is 41.5 kg as background device. The experiment shows that the cool-down time is shortened from 25 hours to 20 hours.
19 August 2024 in IEEE Transactions on Applied Superconductivity
A 3T conduction-cooled animal MRI superconducting magnet was designed, fabricated, and tested. The MRI magnet has a large clear warm bore of Ø300 mm and a center magnetic field strength of 3 T with the measured peak-to-peak homogeneity of 217 ppm in a 180 mm diameter sphere. The magnet consists of 8 coaxial coils placed symmetrically along the axial direction. All coils made with NbTi/Cu superconducting wires were connected in series and were operated with a current of 110 A with a stored energy of about 0.62 MJ. Passive protection based on a subdivided scheme and heater network design is adopted to protect the magnet from damage caused by a quench. A two-stage GM cryocooler with a second-stage cooling power of 1.8 W is used to cool the 3 T animal MRI magnet from room temperature to 4.2 K. In this paper, magnetic design, quench protection, fabrication, and test are presented.
5 January 2026 in IEEE Transactions on Applied Superconductivity
Equivalent contact resistivity is a key parameter that affects the dynamic process and overcurrent characteristic of the non-insulation (NI) high-temperature superconducting coil. Adding stainless steel material between turns of a parallel-wound NI coil results in the formation of various types of internal contact interfaces. Therefore, describing the shunt behavior of the coil, i.e., the parallel-wound metal-insulation (PWMI) coil, requires more than one equivalent contact resistivity, which makes it difficult to determine their specific values only through coil inductance and time constant. To handle this problem, we propose a method to acquire distinct equivalent contact resistivities of the PWMI coil. In this method, the equivalent contact resistivities are inverted based on the measured coil voltage or magnetic field. The bridge to connect the experimental data and equivalent contact resistivities is the streamlined field–circuit coupling model based on the T–A formulation, which can reflect the complex electromagnetic topology and the distribution of equivalent contact resistivities of the PWMI coil. After obtaining the measurement results, the least-squares method is used to optimize the equivalent contact resistivities until the simulation curve is sufficiently consistent with the experimental curve. In order to improve the efficiency of the optimization, we construct the lumped circuit model of the PWMI coil. Before the optimization process begins, the initial values of equivalent contact resistivities can be obtained based on this model, which can reduce the search scope of the optimization. The results of multiprocess testing indicate that using the equivalent contact resistivities obtained by the proposed method can effectively predict the transient behavior of the coil.