Yin Wang

Dr. Yin Wang


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 October 2015 in Sensors
Verified
Journal Article
Open access
PDF file
EZEric Zhang
Eric Zhang
SHStacey Huang
Stacey Huang
QJQixing Ji
Qixing Ji
MSMichael Silvernagel
Michael Silvernagel
YWYin Wang
Yin Wang
GWGerard Wysocki
Gerard Wysocki
We have developed a transportable spectroscopic nitrogen isotopic analyzer. The spectrometer is based on dual-modulation Faraday rotation spectroscopy of nitric oxide isotopologues with near shot-noise limited performance and baseline-free operation. Noise analysis indicates minor isotope (15NO) detection sensitivity of 0.36 ppbv·Hz−1/2, corresponding to noise-equivalent Faraday rotation angle (NEA) of 1.31 × 10−8 rad·Hz−1/2 and noise-equivalent absorbance (αL)min of 6.27 × 10−8 Hz−1/2. White-noise limited performance at 2.8× the shot-noise limit is observed up to ~1000 s, allowing reliable calibration and sample measurement within the drift-free interval of the spectrometer. Integration with wet-chemistry based on acidic vanadium(III) enables conversion of aqueous nitrate/nitrite samples to gaseous NO for total nitrogen isotope analysis. Isotopic ratiometry is accomplished via time-multiplexed measurements of two NO isotope transitions. For 5 μmol potassium nitrate samples, the instrument consistently yields ratiometric precision below 0.3‰, thus demonstrating potential as an in situ diagnostic tool for environmental nitrogen cycle studies.

17 January 2024 in Water
Verified
Journal Article
Open access
PDF file
KWKai Wang
Kai Wang
LHLi Huang
Li Huang
JZJingting Zhang
Jingting Zhang
XZXiaojie Zhen
Xiaojie Zhen
LSLin-lin Shi
Lin-lin Shi
YWYin Wang
Yin Wang
The reliable observation and accurate estimates of land–atmosphere water vapor (H2O) flux is essential for ecosystem management and the development of Earth system models. Currently, the most direct measurement method for H2O flux is eddy covariance (EC), which depends on the development of fast-response H2O sensors. In this study, we presented a cost-efficient open-path H2O analyzer (model: HT1800) based on the tunable diode laser absorption spectroscopy (TDLAS) technique, and investigated its applicability for measuring atmospheric turbulent flux of H2O using the EC method. We prepared two HT1800 analyzers with lasers that operate at wavelengths of 1392 nm and 1877 nm, respectively. The field performance of the two analyzers was evaluated through inter-comparative experiments with LI-7500RS and IRGASON, two of the most commonly used H2O analyzers in the EC community. Water vapor densities measured by the three types of analyzers had high overall agreement with the reference sensor; however, they all experienced drift. The mean density drifts of HT1800, LI-7500 and IRGASON were 3.7–5.2%, 4.0% and 3.8%, respectively. Even so, the half-hourly H2O fluxes measured by HT1800 were highly consistent with those by LI-7500RS and IRGASON (with a difference of less than 2%), suggesting that HT1800 can obtain H2O fluxes with high confidence. The HT1800 was also proved to be suitable for EC application in terms of data availability, flux detection limit and response to the high-frequency turbulent variation. Furthermore, we investigated how the spectroscopic effect influences the measurements of H2O density and flux. Despite the fact that the 1392 nm laser was much more susceptible to the spectroscopic effect, the fluxes after correcting for this bias showed excellent agreement with the IRGASON fluxes. Considering the cost advantage in laser and photodetector, the HT1800 analyzer using a 1392 nm infrared laser is a promising and economical solution for EC measurement studies of water vapor.

29 August 2025 in Sensors
Verified
Journal Article
Open access
PDF file
XJXueying Jin
Xueying Jin
DCDavid Chieng
David Chieng
PKPushpendu Kar
Pushpendu Kar
CKChiew Foong Kwong
Chiew Foong Kwong
YLYeqin Li
Yeqin Li
YWYin Wang
Yin Wang
Continuous and near-real-time monitoring of greenhouse gases (GHGs) is critical for achieving Net Zero emissions, ensuring early detection, compliance, accountability, and adaptive management. To this end, there is an increasing need to monitor GHGs at higher temporal resolutions, greater spatial resolutions, and larger coverage scales. However, spatial resolution and coverage remain significant challenges due to limited sensor network coverage and power sources for sensor nodes, even in urban areas. LoRaWAN, a cost-effective solution that provides long-range and high-penetration wireless connectivity with a low energy consumption, is an ideal choice for this application. Despite its promise, LoRaWAN faces several challenges, including a low data rate, low packet transmission rate, and low packet delivery success ratio, especially when the node density or environment variability is high. This paper presents a simulation-based analysis of a large-scale urban LoRaWAN sensor network operating in the CN470–510 MHz band, which is the only frequency band officially designated for low-power wide-area (LPWA) technologies such as LoRaWAN in China. This study investigates how the node density, sensor measurement update rate (i.e., update interval), and sensor measurement payload size affect two primary performance metrics: the sensor update delivery ratio (DR) and the radio frequency (RF) energy consumption (RFEC) per successful update. The performances of several enhanced adaptive data transmission algorithms in comparison to the conventional ADR+ algorithms are also analysed. The results indicate that both DR and RFEC are significantly influenced by the node density, sensor update rate, and payload size, with the effects being particularly significant under high-node-density and high-update-rate conditions. The analysis further reveals that the ADR-NODE-KAMA algorithm consistently achieves the best performance across most scenarios, providing up to a 2% improvement in DR and a reduction of 10–15 mJ in RFEC per successful sensor measurement update. Additionally, the sensor measurement payload size is shown to have a substantial impact on network performance, with each added sensor measurement contributing to a DR reduction of up to 2.24% and an increase in RFEC of approximately 80 mJ. LoRaWAN network operators can gain practical insights from these findings to optimize the performance and efficiency of large-scale GHG monitoring deployments.

15 May 2023
Verified
Conference Paper
Open access
Longfei YuLongfei Yu
Longfei Yu
YWYin Wang
Yin Wang
ZNZetong Niu
Zetong Niu
ZSZhelin Su
Zhelin Su
LZLintao Zheng
Lintao Zheng
TLTing-Jung Lin
Ting-Jung Lin
Laser spectrometers have shown good capability in measuring mixing ratios for atmospheric greenhouse gases (GHGs). Given the fact that spectral bands of CO2, CH4, and N2O covering from near to mid-infrared (NIR to MIR) wavelengths, and the limitations in the wavelength coverage of the laser and photodetector, it is very challenging to analyze CO2, CH4, and N2O simultaneously for most cavity-enhanced analyzers using NIR lasers. Alternative solutions, such as combining multiple quantum cascade laser (QCL) beams and analyzing all GHGs in the MIR wavelengths, would significantly increase the instrumental cost.Here, we present a recently developed analyzer utilizing the advantages of detecting CO2/H2O in the NIR spectral region and N2O/CH4 in the MIR region, respectively. Through a unique optical design, two independent optical paths are formed in a single Herriott gas cell so that low temperature-related drift and mechanical robustness are achieved. The mixing ratios of CO2 and H2O are analyzed by a NIR laser and a photodetector at ~4995cm-1, while CH4 and N2O are analyzed by a QCL and an MCT photodetector at ~1275cm-1. The analyzer facilitates high-sensitivity, field-deployable measurements of CO2, CH4, N2O and H2O altogether in a compact, portable instrumental design. In addition, this analyzer can be completely powered by rechargeable battery, facilitating all-day in situ measurements without grid power supply.In the laboratory, side-to-side comparisons were performed between our newly developed analyzer and another commercial gas analyzer based on cavity ring down spectroscopy (CRDS). The results showed high consistency in GHG mixing-ratio measurements with the two spectrometers. Attached to soil chambers, we also found comparable performance of two analyzers in determining GHG fluxes. In particular, we found that the presented analyzer could precisely capture transient changes in gas mixing ratios from the soil chamber. Recently, field deployment in different soil conditions, including upland forest soils and riparian soils, was carried out for simultaneous N2O, CH4, CO2 soil flux measurements. The overall results suggest that our analyzer is suitable for continuous GHG flux monitoring under variable field conditions, and shows potentials in simultaneous measurements of multiple GHG fluxes from natural ecosystems.

20 January 2025
Verified
Conference Paper
Open access
YWYin Wang
Yin Wang
KWKai Wang
Kai Wang
JZJingting Zhang
Jingting Zhang
TLTeng Lu
Teng Lu
YZYanze Zhou
Yanze Zhou
TLTing-Jung Lin
Ting-Jung Lin
This work presents an open-path methane (CH4) analyzer (Model HT8600, HealthyPhoton Co., Ltd.) suitable for eddy covariance (EC) flux measurements based on the tunable diode laser absorption spectroscopy (TDLAS) technology. As discussed in the previous literature, EC flux measurements based on open-path analyzers are subject to temperature-correlated corrections, including the density and spectroscopic effects. The HT8600 utilizes an interband cascade laser (ICL) to probe the mid-infrared transition of CH4 at ~3221.1 nm. The chosen absorption peak has the advantage that the density and spectroscopic effects compensate for each other, resulting in low temperature-related corrections in EC flux measurements [1]. The HT8600 has a weight of ~15 kg and dimensions of 84 cm (length) and 20 cm (diameter). Multiple laser beam reflections enable an optical path length of 17 m. The total power consumption is 30 W, which lithium batteries can supply for continuous measurements. Laboratory experiments showed that the HT8600 has a noise level of 1.36 ppbv at a 10-Hz data rate. A long-term field experiment is ongoing to compare the performance of the HT8600 against another commercial open-path CH4 analyzer. We used the fluxes measured by the commercial analyzer with complete temperature corrections as the reference. Preliminary results showed that raw fluxes measured by the HT8600 achieved high consistency with the one from the commercial analyzer, which proved our initiative that the chosen absorption line is subject to low-temperature biases. As the inter-comparison is ongoing, we are collecting more field results for formal analysis of the performance of HT8600 under a wide dynamic range of temperatures. Detailed analysis of the correction factors will be presented at the conference. Meanwhile, as there is a nearby absorption line of water (H2O) at 3222.7 nm, the work extends the analyzer’s capability of measuring H2O and CH4 simultaneously, enhancing its versatility for field CH4 flux monitoring.ReferencePan, D., Gelfand, I., Tao, L., Abraha, M., Sun, K., Guo, X., Chen, J., Robertson, G. P., andZondlo, M. A. (2022). A new open-path eddy covariance method for nitrous oxide and other trace gases that minimizes temperature corrections. Global Change Biology, 28, 1446– 1457. Doi: https://doi.org/10.1111/gcb.15986.

23 March 2020
Verified
Conference Paper
Open access
YWYin Wang
Yin Wang
KWKai Wang
Kai Wang
PKPeng Kang
Peng Kang
YLYin Lu
Yin Lu
XZXiaojie Zhen
Xiaojie Zhen
XZXunhua Zheng
Xunhua Zheng
Ammonia (NH3) emissions from farmlands and livestock are attracting more and more attention. There is an urgent need for ground-based instruments that can acquire the spatial and temporal variability in NH3 concentrations and emissions, particularly in field environments where power and shelter are not readily available. However, accurate measurements of atmospheric NH3 is of great challenges due to its reactive nature. Conventional NH3 instruments are subject to drawbacks, such as slow response time, limited precision, intensive maintenance, or high power consumption due to the use of the closed-path tube, optics, and vacuum pump.We have developed an open-path instrument for fast (10 Hz) and sub-ppbv sensitivity measurements of atmospheric NH3 concentration. The instrument is based on second-harmonic (2f) wavelength modulated laser absorption spectroscopy technique (WM-LAS), which employs a distributed-feedback semiconductor quantum cascade laser (DFB-QCL) and a HgCdTe (MCT) photodetector. An open-path Herriott cell configuration with a 0.5 m physical path and 46 m optical path-length is used for selective and sensitive detection of the mid-infrared absorption transition of NH3 at 9.06 μm [1]. There is no delay due to sample adsorption. The instrument has a precision (1σ noise level) of 0.53 ppbv and 0.15 ppbv at a sampling frequency of 10 Hz and 1 Hz, respectively. The entire NH3 instrument has a weight of ~7 kg and dimensions of 84 cm (length) and 20 cm (diameter). It can be powered by rechargeable lithium batteries, with a total power consumption of as low as 50 W. The instrument has strong environmental adaptability and is suitable for field deployment in various environments. It can be used in ground-based or vehicle-based measurements of atmospheric NH3 concentration.With the good performance in terms of response time and precision, this instrument is an ideal tool for NH3 flux measurements based on the eddy covariance (EC) technique [2]. An EC flux system was built based on the open-path ammonia instrument, which also included a CSAT3 sonic anemometer (Campbell Scientific®) and LI-7500 (LICOR®) for water vapor (H2O) and carbon dioxide (CO2) measurements. The system was installed at a rice paddy field with a typical Chinese-style rice-duck symbiosis system in Jiangsu province, China. Experiments showed that the lower detection limit of the EC system for NH3 flux was around 17ng m-2 s-1.References:[1] Miller, D. J., Sun, K., Tao, L., and Zondlo, M. A.: Open-path, quantum cascade-laser-based sensor for high-resolution atmospheric ammonia measurements, Atmos. Meas. Tech., 7, 81–93,2014.[2] McDermitt, D., Burba, G., Xu, L., Anderson, T., Komissarov, A., Riensche, B., Schedlbauer, J., Starr, G., Zona, D., Oechel, W., Oberbauer, S., and Hastings, S.: A new low-power, open-path instrument for measuring methane flux by eddy covariance, Appl.Phys. B, 102, 391–405, 2011.