Janelle M Fine

Ms. Janelle M Fine

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 April 2025 in Science Translational Medicine
Verified
Journal Article
Closed access
BYBrady M. Youngquist
Brady M. Youngquist
JSJulian Saliba
Julian Saliba
YKYelim Kim
Yelim Kim
TCThomas J. Cutro
Thomas J. Cutro
CLChristopher J. Lyon
Christopher J. Lyon
THTony Hu
Tony Hu
Rapid portable assays are needed to improve diagnosis, treatment, and reduce transmission of tuberculosis (TB), but current tests are not suitable for patients in resource-limited settings with high TB burden. Here we report a low complexity, lab-in-tube system that is read by an integrated handheld device that detects Mycobacterium tuberculosis ( Mtb ) DNA in blood and respiratory samples from a variety of clinical settings. This microprocessor-controlled device uses an LCD user interface to control assay performance, automate assay analysis, and provide results in a simple readout. This point-of-care single-tube assay uses a DNA enrichment membrane and a low-cost cellulose disc containing lyophilized recombinase polymerase amplification and CRISPR-Cas12a reagents to attain single-nucleotide specificity and high sensitivity within 1 hour of sample application, without a conventional DNA isolation procedure. Assay results obtained with serum cell–free DNA isolated from a cohort of children aged 1 to 16 years detected pulmonary and extrapulmonary TB with high sensitivity versus culture and GeneXpert MTB/RIF results (81% versus 55% and 68%) and good specificity (94%), meeting the World Health Organization target product profile criteria for new nonsputum TB diagnostics. Changes in assay results for serum isolated during treatment were also highly predictive of clinical response. Results obtained with noninvasive sputum and saliva specimens from adults with bacteriologically confirmed pulmonary TB were also comparable to those reported for reference methods. This rapid and inexpensive lab-in-tube assay approach thus represents one means to address the need for point-of-care TB diagnostics useable in low-resource settings.

24 February 2025 in Chronobiology International
Verified
Journal Article
Open access
NCNikhil Chilakapati
Nikhil Chilakapati
LTLiz Timple
Liz Timple
SPSophia Pizzi
Sophia Pizzi
JFJanelle M Fine
Janelle M Fine
HMHirsh Makhija
Hirsh Makhija
BKBiren B. Kamdar
Biren B. Kamdar
The intensive care unit (ICU) environment is designed for the care of acutely ill patients, with lighting conditions reflecting the needs of the busy clinical setting. Earlier ICU studies suggested that daytime and nighttime light levels were misaligned with those required for circadian rhythm entrainment, which can impact patient sleep-wake cycles and recovery from critical illness. In this investigation in San Diego, California, a coastal US city with over 260 days of sunshine annually, we performed a detailed evaluation of light levels in a contemporary academic medical-surgical ICU constructed in 2016, which features modern lighting and floor-to-ceiling windows in each of the 24 rooms. Using light meters mounted on poles and located directly behind the head of each patient's bed, our analysis of nearly 90,000 hours of data revealed daytime ICU light levels consistently lower than 150 lx, similar to studies in older ICUs and many magnitudes lower than outdoor levels at identical times. Hence, despite the modern design, we found that little to no light from the ~100 ft2 windows reached the patient. While daytime light levels were low across all ICU rooms, those with windows facing South and Northwest featured higher light levels than those facing Southeast and Northeast, suggesting a contribution of window direction to ICU light levels.

15 August 2013 in Journal of Applied Physiology
Verified
Journal Article
Open access
PDF file
CDC. Darquenne
C. Darquenne
KZK. L. Zeman
K. L. Zeman
RSR. C. Sá
R. C. Sá
TCT. K. Cooper
T. K. Cooper
JFJanelle M Fine
Janelle M Fine
GPG. K. Prisk
G. K. Prisk
Lung deposition of >0.5-μm particles is strongly influenced by gravitational sedimentation, with deposition being reduced in microgravity (μG) compared with normal gravity (1G). Gravity not only affects total deposition, but may also alter regional deposition. Using gamma scintigraphy, we measured the distribution of regional deposition and retention of radiolabeled particles (99mTc-labeled sulfur colloid, 5-μm diameter) in five healthy volunteers. Particles were inhaled in a controlled fashion (0.5 l/s, 15 breaths/min) during multiple periods of μG aboard the National Aeronautics and Space Administration Microgravity Research Aircraft and in 1G. In both cases, deposition scans were obtained immediately postinhalation and at 1 h 30 min, 4 h, and 22 h postinhalation. Regional deposition was characterized by the central-to-peripheral ratio and by the skew of the distribution of deposited particles on scans acquired directly postinhalation. Relative distribution of deposition between the airways and the alveolar region was derived from data acquired at the various time points. Compared with inhalation in 1G, subjects show an increase in central-to-peripheral ratio (P = 0.043), skew (P = 0.043), and tracheobronchial deposition (P < 0.001) when particles were inhaled in μG. The absence of gravity caused fewer particles to deposit in the lung periphery than in the central region where deposition occurred mainly in the airways in μG. Furthermore, the increased skew observed in μG likely illustrates the presence of localized areas of deposition, i.e., “hot spots”, resulting from inertial impaction. In conclusion, gravity has a significant effect on deposition patterns of coarse particles, with most of deposition occurring in the alveolar region in 1G but in the large airways in μG.

30 September 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MMMaryam Maghsoudipour
Maryam Maghsoudipour
BNBrandon Nokes
Brandon Nokes
NBNaa-Oye Bosompra
Naa-Oye Bosompra
RJRachel Jen
Rachel Jen
YLYanru Li
Yanru Li
AMAtul Malhotra
Atul Malhotra
The genioglossus is a major upper airway dilator muscle. Our goal was to assess the efficacy of upper airway muscle training on Obstructive Sleep Apnea (OSA) as an adjunct treatment. Sixty-eight participants with OSA (AHI > 10/h) were recruited from our clinic. They fall into the following categories: (a) Treated with Automatic Positive Airway Pressure (APAP), (n = 21), (b) Previously failed APAP therapy (Untreated), (n = 25), (c) Treated with Mandibular Advancement Splint (MAS), (n = 22). All subjects were given a custom-made tongue strengthening device. We conducted a prospective, randomized, controlled study examining the effect of upper airway muscle training. In each subgroup, subjects were randomized to muscle training (volitional protrusion against resistance) or sham group (negligible resistance), with a 1:1 ratio over 3 months of treatment. In the baseline and the final visit, subjects completed home sleep apnea testing, Epworth Sleepiness Scale (ESS), Pittsburgh Sleep Quality Index (PSQI), SF-36 (36-Item Short Form Survey), and Psychomotor Vigilance Test (PVT). Intervention (muscle training) did not affect the AHI (Apnea-Hypopnea Index), (p-values > 0.05). Based on PSQI, ESS, SF-36 scores, and PVT parameters, the changes between the intervention and sham groups were not significant, and the changes were not associated with the type of treatment (p-value > 0.05). The effectiveness of upper airway muscle training exercise as an adjunct treatment requires further study.

26 September 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
W. Cameron McGuireW. Cameron McGuire
W. Cameron McGuire
APAlex K. Pearce
Alex K. Pearce
AEAnn Elliott
Ann Elliott
JFJanelle M Fine
Janelle M Fine
JWJohn B. West
John B. West
AMAtul Malhotra
Atul Malhotra
Background and Objective: The COVID-19 pandemic magnified the importance of gas exchange abnormalities in early respiratory failure. Pulse oximetry (SpO2) has not been universally effective for clinical decision-making, possibly because of limitations. The alveolar gas monitor (AGM100) adds exhaled gas tensions to SpO2 to calculate the oxygen deficit (OD). The OD parallels the alveolar-to-arterial oxygen difference (AaDO2) in outpatients with cardiopulmonary disease. We hypothesized that the OD would discriminate between COVID-19 patients who require hospital admission and those who are discharged home, as well as predict need for supplemental oxygen during the index hospitalization. Methods: Patients presenting with dyspnea and COVID-19 were enrolled with informed consent and had OD measured using the AGM100. The OD was then compared between admitted and discharged patients and between patients who required supplemental oxygen and those who did not. The OD was also compared to SpO2 for each of these outcomes using receiver operating characteristic (ROC) curves. Results: Thirty patients were COVID-19 positive and had complete AGM100 data. The mean OD was significantly (p = 0.025) higher among those admitted 50.0 ± 20.6 (mean ± SD) vs. discharged 27.0 ± 14.3 (mean ± SD). The OD was also significantly (p < 0.0001) higher among those requiring supplemental oxygen 60.1 ± 12.9 (mean ± SD) vs. those remaining on room air 25.2 ± 11.9 (mean ± SD). ROC curves for the OD demonstrated very good and excellent sensitivity for predicting hospital admission and supplemental oxygen administration, respectively. The OD performed better than an SpO2 threshold of <94%. Conclusions: The AGM100 is a novel, noninvasive way of measuring impaired gas exchange for clinically important endpoints in COVID-19.

23 June 2023 in Journal of the Intensive Care Society
Verified
Journal Article
Closed access
BKBiren B Kamdar
Biren B Kamdar
JFJanelle M Fine
Janelle M Fine
MPMarie T Pavini
Marie T Pavini
SASara S Ardren
Sara S Ardren
SBStephanie Burns
Stephanie Burns
RSRenee D Stapleton
Renee D Stapleton
Background: Mechanically ventilated Intensive Care Unit (ICU) patients often require wrist restraints, contributing to immobility and agitation, over-sedation, and delirium. The Exersides® Refraint® (Healthy Design, LLC), a novel restraint alternative, may be safe and facilitate greater mobility than traditional restraints. Objective: This National Institutes of Health Small Business Technology Transfer (STTR) Program Grant-funded single-site Phase I feasibility study evaluated Exersides® safety and feasibility in anticipation of a multi-site Phase II randomized controlled trial (RCT). Methods: In two academic ICUs, mechanically ventilated adults ⩾25 years old who were non-comatose, required restraints and had an expected stay of ⩾2 days were enrolled to wear Exersides® and traditional wrist restraints for 4 h on day 1, in a randomized order, and in the reverse order on day 2. Main outcomes were Exersides® safety (i.e., patient/clinician lacerations/injuries), feasibility (i.e., ⩾90% of required data collected), and patient/family/clinician feedback. Results: Eight patients were enrolled; one no longer required restraints at initiation, yielding seven subjects (median [interquartile range (IQR)] age 65 [55, 70] years, 86% men). All seven wore Exersides®, averaging (SD) 2.5 (1.0) hours per session, with no safety events reported. Across restraint time periods, 92% and 100% of Richmond Agitation-Sedation Scale (RASS) and wrist actigraphy data, respectively, were collected. Feedback was positive (more movement and comfortable than traditional restraints) and constructive (bulky, intimidating to apply). Conclusions: This pilot study provided key safety and feasibility data for a Phase II RCT evaluating Exersides® versus traditional wrist restraints. Feedback motivated minor device modifications before RCT initiation.