Gordon Kim Prisk

Gordon Kim Prisk

Auto-generated profile, based on publicly available information

Gordon Kim Prisk

Department of Medicine, University of California, San Diego, California, United States

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 December 2022 in npj Microgravity
Verified
Journal Article
Open access
PDF file
MPMichael Pohlen
Michael Pohlen
DCDanielle Carroll
Danielle Carroll
GPG. Kim Prisk
G. Kim Prisk
ASAenor J. Sawyer
Aenor J. Sawyer
Lunar dust (LD), the component of lunar regolith with particle sizes less than 20 μm, covers the surface of the Moon. Due to its fineness, jagged edges, and electrostatic charge, LD adheres to and coats almost any surface it contacts. As a result, LD poses known risks to the proper functioning of electronic and mechanical equipment on the lunar surface. However, its mechanical irritancy and chemical reactivity may also pose serious health risks to humans by a number of mechanisms. While Apollo astronauts reported mild short-lived respiratory symptoms, the spectrum of health effects associated with high-dose acute exposure or chronic low-dose exposure are not yet well-understood. This paper explores known and potential human risks of exposure to LD which are thought to be important in planning upcoming lunar missions and planetary surface work.

1 February 2023 in Annals of the American Thoracic Society
Verified
Journal Article
Open access
Connie C.W. HsiaConnie C.W. Hsia
Connie C.W. Hsia
JBJason Bates
Jason Bates
BDBastiaan Driehuys
Bastiaan Driehuys
SFSean Fain
Sean Fain
JGJonathan G. Goldin
Jonathan G. Goldin
SHSusan R. Hopkins
Susan R. Hopkins
Multiple thoracic imaging modalities have been developed to link structure to function in the diagnosis and monitoring of lung disease. Volumetric computed tomography (CT) renders three-dimensional maps of lung structures and may be combined with positron emission tomography (PET) to obtain dynamic physiological data. Magnetic resonance imaging (MRI) using ultrashort–echo time (UTE) sequences has improved signal detection from lung parenchyma; contrast agents are used to deduce airway function, ventilation–perfusion–diffusion, and mechanics. Proton MRI can measure regional ventilation-perfusion ratio. Quantitative imaging (QI)–derived endpoints have been developed to identify structure–function phenotypes, including air–blood–tissue volume partition, bronchovascular remodeling, emphysema, fibrosis, and textural patterns indicating architectural alteration. Coregistered landmarks on paired images obtained at different lung volumes are used to infer airway caliber, air trapping, gas and blood transport, compliance, and deformation. This document summarizes fundamental “good practice” stereological principles in QI study design and analysis; evaluates technical capabilities and limitations of common imaging modalities; and assesses major QI endpoints regarding underlying assumptions and limitations, ability to detect and stratify heterogeneous, overlapping pathophysiology, and monitor disease progression and therapeutic response, correlated with and complementary to, functional indices. The goal is to promote unbiased quantification and interpretation of in vivo imaging data, compare metrics obtained using different QI modalities to ensure accurate and reproducible metric derivation, and avoid misrepresentation of inferred physiological processes. The role of imaging-based computational modeling in advancing these goals is emphasized. Fundamental principles outlined herein are critical for all forms of QI irrespective of acquisition modality or disease entity.

24 March 2022 in Journal of Applied Physiology
Verified
Journal Article
Closed access
PDF file
PWPeter D. Wagner
Peter D. Wagner
AMAtul Malhotra
Atul Malhotra
GPGordon Kim Prisk
Gordon Kim Prisk
Identifying pulmonary vascular obstruction in the presence of pneumonia (e.g., in COVID-19) is difficult. We present here conversion of bedside measurements of arterial and alveolar Po2 and Pco2 into values for shunt and deadspace—when both coexist—using Riley and Cournand’s 3-compartment gas exchange model. Deadspace values higher than expected from shunt alone indicate high ventilation/perfusion ratio areas likely reflecting (micro)vascular obstruction.

1 September 2022 in Journal of Applied Physiology
Verified
Journal Article
Closed access
PDF file
COClaire F. O’sUllivan
Claire F. O’sUllivan
KNKris Nilsen
Kris Nilsen
BBBrigitte Borg
Brigitte Borg
MEMatthew Ellis
Matthew Ellis
PMPam Matsas
Pam Matsas
BTBruce R. Thompson
Bruce R. Thompson
There is a poor understanding of why some patients with asthma experience recurrent exacerbations despite high levels of treatment. We compared measurements of peripheral ventilation heterogeneity and respiratory system mechanics in participants with asthma who were differentiated according to exacerbation history, to ascertain whether peripheral airway dysfunction was related to exacerbations. Three asthmatic groups: “stable” (no exacerbations for >12 mo, n = 18), “exacerbation-prone” (≥1 exacerbation requiring systemic corticosteroids within the last 12 mo, but stable for ≥1-mo, n = 9), and “treated-exacerbation” (exacerbation requiring systemic corticosteroids within the last 1 mo, n = 12) were studied. All participants were current nonsmokers with <10 pack yr smoking history. Spirometry, static lung volumes, ventilation heterogeneity from multibreath nitrogen washout (MBNW), and respiratory system mechanics from oscillometry were measured. The exacerbation-prone group compared with the stable group had slightly worse spirometry [forced expired volume in 1 s or FEV1 z-score −3.58(1.13) vs. −2.32(1.06), P = 0.03]; however, acinar ventilation heterogeneity [Sacin z-score 7.43(8.59) vs. 3.63(3.88), P = 0.006] and respiratory system reactance [Xrs cmH2O·s·L−1 −2.74(3.82) vs. −1.32(1.94), P = 0.01] were much worse in this group. The treated-exacerbation group had worse spirometry but similar small airway function, compared with the stable group. Patients with asthma who exacerbate have worse small airway function as evidenced by increases in Sacin measured by MBNW and ΔXrs from oscillometry, both markers of small airway dysfunction, compared with those that do not. NEW & NOTEWORTHY This study assessed the relationship between peripheral airway function, measured by multiple breath nitrogen washout and oscillometry impedance, and exacerbation history. We found that those with a history of exacerbation in the last year had worse peripheral airway function, whereas those recently treated for an asthma exacerbation had peripheral airway function that was comparable to the stable group. These findings implicate active peripheral airway dysfunction in the pathophysiology of an asthma exacerbation.

21 October 2021 in Frontiers in Physiology
Verified
Journal Article
Open access
GPG. Kim Prisk
G. Kim Prisk
JWJohn B. West
John B. West
The efficiency of pulmonary gas exchange has long been assessed using the alveolar-arterial difference in PO2, the A-aDO2, a construct developed by Richard Riley ~70years ago. However, this measurement is invasive (requiring an arterial blood sample), time consuming, expensive, uncomfortable for the patients, and as such not ideal for serial measurements. Recent advances in the technology now provide for portable and rapidly responding measurement of the PO2 and PCO2 in expired gas, which combined with the well-established measurement of arterial oxygen saturation via pulse oximetry (SpO2) make practical a non-invasive surrogate measurement of the A-aDO2, the oxygen deficit. The oxygen deficit is the difference between the end-tidal PO2 and the calculated arterial PO2 derived from the SpO2 and taking into account the PCO2, also measured from end-tidal gas. The oxygen deficit shares the underlying basis of the measurement of gas exchange efficiency that the A-aDO2 uses, and thus the two measurements are well-correlated (r2~0.72). Studies have shown that the new approach is sensitive and can detect the age-related decline in gas exchange efficiency associated with healthy aging. In patients with lung disease the oxygen deficit is greatly elevated compared to normal subjects. The portable and non-invasive nature of the approach suggests potential uses in first responders, in military applications, and in underserved areas. Further, the completely non-invasive and rapid nature of the measurement makes it ideally suited to serial measurements of acutely ill patients including those with COVID-19, allowing patients to be closely monitored if required.

15 August 2013 in Journal of Applied Physiology
Verified
Journal Article
Open access
PDF file
CDC. Darquenne
C. Darquenne
KZK. L. Zeman
K. L. Zeman
RSR. C. Sá
R. C. Sá
TCT. K. Cooper
T. K. Cooper
JFJanelle M Fine
Janelle M Fine
GPG. K. Prisk
G. K. Prisk
Lung deposition of >0.5-μm particles is strongly influenced by gravitational sedimentation, with deposition being reduced in microgravity (μG) compared with normal gravity (1G). Gravity not only affects total deposition, but may also alter regional deposition. Using gamma scintigraphy, we measured the distribution of regional deposition and retention of radiolabeled particles (99mTc-labeled sulfur colloid, 5-μm diameter) in five healthy volunteers. Particles were inhaled in a controlled fashion (0.5 l/s, 15 breaths/min) during multiple periods of μG aboard the National Aeronautics and Space Administration Microgravity Research Aircraft and in 1G. In both cases, deposition scans were obtained immediately postinhalation and at 1 h 30 min, 4 h, and 22 h postinhalation. Regional deposition was characterized by the central-to-peripheral ratio and by the skew of the distribution of deposited particles on scans acquired directly postinhalation. Relative distribution of deposition between the airways and the alveolar region was derived from data acquired at the various time points. Compared with inhalation in 1G, subjects show an increase in central-to-peripheral ratio (P = 0.043), skew (P = 0.043), and tracheobronchial deposition (P < 0.001) when particles were inhaled in μG. The absence of gravity caused fewer particles to deposit in the lung periphery than in the central region where deposition occurred mainly in the airways in μG. Furthermore, the increased skew observed in μG likely illustrates the presence of localized areas of deposition, i.e., “hot spots”, resulting from inertial impaction. In conclusion, gravity has a significant effect on deposition patterns of coarse particles, with most of deposition occurring in the alveolar region in 1G but in the large airways in μG.