Dario Guarda

Dr. Dario Guarda

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 July 2023 in International Journal of Refrigeration
Verified
Journal Article
Open access
DGDario Guarda
Dario Guarda
GRGiulia Righetti
Giulia Righetti
GLGiovanni A. Longo
Giovanni A. Longo
CZClaudio Zilio
Claudio Zilio
SMSimone Mancin
Simone Mancin

3 February 2023 in Journal of Energy Storage
Verified
Journal Article
Open access
JGJorge Martinez Garcia
Jorge Martinez Garcia
DGDamian Gwerder
Damian Gwerder
FWFabian Wahli
Fabian Wahli
DGDario Guarda
Dario Guarda
BFBenjamin Fenk
Benjamin Fenk
PSPhilipp Schuetz
Philipp Schuetz

25 August 2023 in International Journal of Thermal Sciences
Verified
Journal Article
Closed access
DGDario Guarda
Dario Guarda
JGJorge Martinez Garcia
Jorge Martinez Garcia
BFBenjamin Fenk
Benjamin Fenk
DSDavid Schiffmann
David Schiffmann
DGDamian Gwerder
Damian Gwerder
PSPhilipp Schuetz
Philipp Schuetz

12 June 2024 in Applied Thermal Engineering
Verified
Journal Article
Open access
DGDario Guarda
Dario Guarda
JMJorge Martinez-Garcia
Jorge Martinez-Garcia
BFBenjamin Fenk
Benjamin Fenk
POPoppy O’nEill
Poppy O’nEill
RRRebecca Ravotti
Rebecca Ravotti
PSPhilipp Schuetz
Philipp Schuetz

4 September 2025 in Energies
Verified
Journal Article
Open access
PDF file
JGJorge Martinez Garcia
Jorge Martinez Garcia
DGDario Guarda
Dario Guarda
DGDamian Gwerder
Damian Gwerder
BFBenjamin Fenk
Benjamin Fenk
Rebecca RavottiRebecca Ravotti
Rebecca Ravotti
PSPhilipp Schuetz
Philipp Schuetz
Latent heat thermal energy storage (LHTES) based on phase change materials (PCMs) is receiving increasing interest since it offers high energy storage density while enabling the integration of variable renewable energies, hence boosting the transition towards a climate-neutral future. Despite the advantages that PCMs offer in providing a nearly isothermal solid–liquid phase transition, they still face some challenges that limit their deployment in real applications such as low thermal conductivity, phase separation, and supercooling, which affect charging and discharging rates. X-ray computed tomography (XCT) is a non-destructive imaging technique widely used in materials science for both qualitative and quantitative analysis of material microstructures and their evolution. Recent advances in laboratory-XCT instrumentation enabled short acquisition times on the order of tens of seconds which allows the investigation of dynamic processes in situ by time-lapse XCT measurements. These advances open new opportunities for revealing information on the morphology of solid–liquid PCMs. Despite the fact that XCT imaging has significant potential for energy research, its application in the field of PCMs is fairly new. A key enabler of applications of XCT to PCMs is the density difference between solid and liquid PCMs, which was found to be higher than 7% for all investigated PCMs. This enabled solid and liquid phases to be distinguished one from the other and properly quantified over time. The present work reviews the principles of laboratory-based XCT and the recent applications of XCT technology in the characterisation of PCMs, with emphasis on the study of the solid–liquid phase transition and validation of numerical PCM models by addressing the potentialities and challenges of XCT in PCM research.

2 July 2025 in Energies
Verified
Journal Article
Open access
PDF file
CZClaudio Zilio
Claudio Zilio
GRGiulia Righetti
Giulia Righetti
DGDario Guarda
Dario Guarda
FMFrancesca Martelletto
Francesca Martelletto
Mancin SimoneMancin Simone
Mancin Simone
The decarbonization of residential cooling systems requires innovative solutions to overcome the mismatch between the renewable energy availability and demand. Integrating latent thermal energy storage (LTES) with heat pump/air conditioning (HP/AC) units can help balance energy use and enhance efficiency. However, the dynamic behavior of such integrated systems, particularly under low-load conditions, remains underexplored. This study investigates a 5 kW HP/AC unit coupled with an 18 kWh LTES system using a bio-based Phase Change Material (PCM) with a melting temperature of 9 °C. Two configurations were tested: charging the LTES using either a thermostatic bath or the HP/AC unit. Key parameters such as the stored energy, temperature distribution, and cooling capacity were analyzed. The results show that, under identical conditions (2 °C inlet temperature, 16 L/min flow rate), the energy stored using the HP/AC unit was only 6.3% lower than with the thermostatic bath. Nevertheless, significant cooling capacity fluctuations occurred with the HP/AC unit due to compressor modulation and anti-frost cycles. The compressor frequency varied from 75 Hz to 25 Hz, and inefficient on-off cycling appeared in the final phase, when the power demand dropped below 1 kW. These findings highlight the importance of integrated system design and control strategies. A co-optimized HP/AC–LTES setup is essential to avoid performance degradation and to fully exploit the benefits of thermal storage in residential cooling.