An analytical study was carried out on an anchored circular pit with a submerged free surface in layered soil. The seepage field around the anchor circular pit was divided into three zones. Separate variable method was used to obtain the graded solution forms of head distribution in the column coordinate system for each of the three regions. Combined with the continuity condition between the regions the Bessel function orthogonality was used to obtain the explicit analytical solution of the seepage field in each region, and the infiltration line was determined. Comparison with the calculation results of Plaxis 2D 8.5 software verified the correctness of the analytical solution. Based on the analytical solution, the influence of the radius of the pit and the distance of the retaining wall from the top surface of the impermeable layer on the total head distribution on both sides of the retaining wall was analyzed. And the variation in the infiltration line was determined with the above parameters. The results show that as the pit radius, r, decreased, the total head on both sides of the retaining wall gradually increased, and the height of the submerged surface drop also increased. As the distance, a, between the retaining wall and the impermeable boundary at the bottom increased, the hydraulic head on the outer side of the retaining wall decreased and the head on the inner side increased. The height of the submerged surface drop increased with decreasing depth of insertion of the retaining wall. The depth of insertion of the retaining wall had a greater influence on the degree of diving surface drop than the pit radius.
The soil piping and drift sand phenomenon is one of the catastrophic failure forms in foundation pit excavations in coastal buildings. Presently, there is a deficiency in the theoretical research regarding the seepage fields around foundation pits, primarily due to the complexity of theoretical solutions given the difficulty in accurately describing the distribution of the groundwater’s hydraulic head in a seepage field. This study proposes an explicit analytical solution for the steady-state seepage field surrounding a foundation pit under anisotropic conditions. A numerical model, constructed with FLAC3D 7.0 software, was utilized to validate the solution presented in this study. The effects of the foundation pit’s width, the distance between the retaining wall and the impervious layer, and anisotropic seepage conditions on the total head are studied through parameter research. The study shows that the flow behavior of a foundation pit is sensitive to parameters such as the anisotropy of the soil layer and the width of the foundation pit. Further, the study also analyzes the influence of the above parameters on the exit gradient and proposes a simplified algorithm for the exit hydraulic gradient at the base of a foundation pit, which can control the error within 5%. This method makes a certain contribution to improving seepage calculations for foundation pits and is applicable to the seepage problem of anisotropic soil layers.
In recent years, with the increasing difficulty of foundation pit projects, the frequency of leakage accidents has also increased. In order to ensure that the excavation of foundation pits is carried out smoothly, water-stop curtains are generally used to protect the foundation pit. Once leakage occurs in the water-stop curtain, it will inevitably delay the schedule, cause significant harm, and even jeopardize life. Therefore, this paper analyses and investigates the two-steady-state seepage field of the foundation pit when the permeable anisotropic soil layer suspends the leakage of the water curtain. To calculate head distribution solutions, the soil layer surrounding the curtain was divided into five regular regions, and the superposition method and method of separating variables were used. These results were then combined with the continuity conditions between the regions to obtain the explicit analytical solutions of the seepage flow field around the pit. Calculations were compared using finite element software and other references, and the results were in good agreement, verifying the correctness of the analytical solution. Parameter analysis showed that the location and width of vertical leakage cracks have limited influence on the head distribution of the foundation pit and water pressure around the water curtain, but significant influence on the seepage flow at the leakage location.