Maruf Mortula

Prof. Maruf Mortula

American University of Sharjah, Sharjah, UAE
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2021 in Journal of Environmental Management
Verified
Journal Article
Closed access
Maruf MortulaMaruf Mortula
Maruf Mortula
Serter AtabaySerter Atabay
Serter Atabay
KFKazi Fattah
Kazi Fattah
AMAhmad Madbuly
Ahmad Madbuly

7 May 2021 in IEEE Access
Verified
Journal Article
Open access
MYMohamed YAHIA
Mohamed YAHIA
Rahul Onkar GawaiRahul Onkar Gawai
Rahul Onkar Gawai
Tarig AliTarig Ali
Tarig Ali
Maruf MortulaMaruf Mortula
Maruf Mortula
LALutfi Albasha
Lutfi Albasha
TLTaha Landolsi
Taha Landolsi
Waterleakage detection and localization in distribution networks pipelines is a challenge for utility companies. For this purpose, thermal Infrared Radiation (IR) techniques have been widely applied in the literature. However, the classical analysis of IR images has not been robust in detecting and locating leakage, due to presence of thermal anomalies such as shadows. In this study, to improve the detection and location accuracy, a digital image processing tool based on multitemporal IR is proposed. In multitemporal IR analysis, the variation of soil's temperature due to field temperature can be obtained; and hence; estimating variations due to water leakage would be more accurate. An experimental setup was built to evaluate the proposed multitemporal IR water leak detection method. In order to consider the temporal temperature variation due to water leakage and mitigate the field temperature effects, a luminance transformation of the IRimages was introduced. To determine the temporal temperature variation of the soil's surface due to the leakage, several metrics have been considered such as the difference, the ratio, the log-ratio and the coefficient variation (CV) images. Based on the experimental results, the log-ratio and the CVimages were the most robust metrics. Then, based on log-ratio or the CV image, a temporal variation image (TVI) that traduces the temporal IR luminance variation was introduced. The analysis of the TVI image showed that the CV image is less noisy than the log-ratio image, and can more accurately locate the leakage. Finally, based on TVI histogram, a threshold was defined to classify the TVI image into leakage/non-leakage areas. Results showed that the proposed method is capable of accurately detecting and locating water leakage, which is an improvement to the false detections of spatial thermal IR analysis.

25 April 2025 in Frontiers in Sustainable Cities
Verified
Journal Article
Open access
PDF file
HSHafsa Shajidha
Hafsa Shajidha
Maruf MortulaMaruf Mortula
Maruf Mortula
The sustainability of the construction industry largely depends on effective waste management practices throughout both construction and demolition processes. Construction and demolition waste causes significant environmental degradation, resource depletion, and landfill overflow, making effective waste management an essential component of sustainable construction practices. As the construction industry is one of the biggest contributors of generated waste in today’s world, achieving sustainability in this industry is essential for overall sustainable development. This study aims to examine the sustainable approach to construction and demolition waste and develop strategies for the industry. Based on the evaluation of various waste management techniques, this study used a standard approach in examining existing literature available in renowned research databases and key concepts to develop strategies for future construction and demolition waste management. This included identifying appropriate keywords or combining multiple keywords during the search process. Waste reduction and protecting the planet’s precious natural resources have been the focus of this study. This research investigated strategies during the planning and design phases. Out of the three strategies tested; reduction at the source, recycling, and reuse, source reduction yields the best results. Selecting materials, optimizing designs, and improving processes are all essential techniques for source reduction. Additionally, it explores the role of policy interventions and regulatory frameworks in improving source reduction practices across the industry. However, as waste reduction may not always eliminate waste generation, especially during the demolition of buildings, it is important to supplement this with existing recycling and reuse approaches. With the use of alternative building materials, it is essential to reassess recycling and reuse options for innovative and sustainable construction materials. The findings illustrate that efficient waste reduction regulations, such as green building certifications and mandatory waste management plans, are critical to achieving sustainability. By incorporating source reduction measures in addition to recycling and reuse of waste management, the construction may drastically minimize its environmental effect while increasing cost efficiency and resource usage. This study emphasizes that source reduction should be mandatory for accomplishing sustainable construction and demolition waste management. Recycling and reuse should complement waste reduction efforts.

6 February 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
HAHuda Aslam
Huda Aslam
Maruf MortulaMaruf Mortula
Maruf Mortula
Sherif YehiaSherif Yehia
Sherif Yehia
Tarig AliTarig Ali
Tarig Ali
MKManreet Kaur
Manreet Kaur
Leakages from water distribution infrastructures are responsible for a considerable amount of water losses. Consequently, innovative, non-destructive techniques (NDT) of leakage detection for early recognition is vital. In this study, the leak detection abilities of Ground Penetration Radar (GPR), spectrometers, and infrared (IR) cameras were investigated, and the factors affecting the leak detection response were assessed. Three experimental setups were constructed to simulate underground pipes in dune sand. Three different pipe materials (PVC, PPR, and PE) were investigated under three levels of moisture content (MC; 2%, 5%, and 10%) and three types of leaks (hole, crack, and faulty joint). The IR camera was the most effective among the different NDTs used in this study. The IR camera detected all types of leaks at 2% and 5% MC but was inconclusive at 10% MC. Similarly, the GPR detected the leaks at 2% and 5% MC successfully but was inconclusive at 10% MC. Lastly, the spectrometer was the least reliable NDT to detect leaks. Results suggest that IR cameras and spectrometers that operate in the mid-IR range (5–25 µm) can detect leaks.

1 September 2020 in Journal of Management in Engineering
Verified
Journal Article
Closed access
PDF file
Maruf MortulaMaruf Mortula
Maruf Mortula
AAAshraf Ahmed
Ashraf Ahmed
ASArif Mohaimin Sadri
Arif Mohaimin Sadri
Tarig AliTarig Ali
Tarig Ali
IAIrtishad Ahmad
Irtishad Ahmad
AIAlaeldin Idris
Alaeldin Idris
A water supply system is a key infrastructure providing critical services to city-dwellers. Due to major disaster events causing a water shortage, the supply systems can be vulnerable. This paper presents a study aimed at evaluating vulnerability in a water supply system and finding ways to improve its resiliency. The water supply system in the city of Sharjah, United Arab Emirates, is investigated as a case study for this research. The study developed an approach for improving resiliency of various components within a water supply system, including water source, treatment systems, and distribution networks. A network analysis of water distribution network was conducted in order to evaluate the vulnerable nodes based on their centrality and degree of interconnections. In addition, hydraulic analysis of the network was also conducted in order to identify the critical nodes that can be impacted by water shortages. Common and vulnerable nodes from both network and hydraulic analyses are identified to prioritize managerial actions for improvement of resiliency. A management plan is outlined in the paper to improve resiliency of the water supply system. The plan includes three different goals to achieve resiliency in a typical water supply system in the wake of a disaster event. These are reducing network vulnerability, increasing diversity of source water, and eliminating possibilities of water contamination. A set of priorities for implementation as maintenance activities is developed for use by management. The high-impact scenarios received higher priority, and low-impact scenarios received lower priority. In addition, the study recommends diversifying the source water, with less dependency on seawater. Diversifying the type of desalination techniques is recommended to increase the ability of water treatment plants for ensuring maintenance of desired water quality during times of disaster. The lessons learned from this case study will be useful to the management of infrastructures where resiliency needs to be improved. Major steps as outlined in this paper are identification of vulnerabilities, prioritizing action steps depending on the degree of impacts, and diversifying sources of supply and methods of treatments.

10 February 2020 in IEEE Access
Verified
Journal Article
Open access
Ameen Ayman AwwadAmeen Ayman Awwad
Ameen Ayman Awwad
MYMohamed YAHIA
Mohamed YAHIA
LALutfi Albasha
Lutfi Albasha
Maruf MortulaMaruf Mortula
Maruf Mortula
Tarig AliTarig Ali
Tarig Ali
MOMortula
Mortula
Water leaks in the distribution network produce significant losses and cause serious economic inconvenience especially in areas with water shortage. In this paper, the operational aspects of the most popular offline detection technologies, ground penetrating radars (GPR’s), infrared (IR) cameras, and acoustic detectors, were compared. The authors also studied the potential of using the recent Terahertz imaging technology for the same application. Acoustic detectors were found the most suitable technology for the atmosphere in UAE, where the levels of humidity and, consequently, soil moisture are high, because both of GPRs and IR cameras operational capability to detect leaks tend to decrease sharply as soil moisture increases. On the other side, a conventional acoustic detector has very limited scope of detection. This paper presents a method of expanding the sensing component of acoustic detectors by connecting acoustic sensors through a digital communication system using the 3G/4G networks to a monitoring center with an acoustic spectrum analyzer. The novelty of this system is its ability to provide offline detection of leakages in the underground water pipelines remotely without deforming the surrounding environment or adjusting the acoustic detector’s analyzing system. Simulation results proves the ability of the system to reconstruct the input noise signal at the end of the proposed network which is to be connected to the acoustic analyzer.