In any vapor compression system, lubricant is needed to guarantee safe and reliable compressor operation. Indeed, most compressor mechanical failures are generally due to improper oil management, such as, lack of proper lubrication inside the compressor. Since in the usual operating condition of the system a small portion of oil circulates with the refrigerant through the system components, it can be retained inside the heat exchangers leading to oil missing from the compressor. In present article, the lubricant retention characteristics of two microchannel type evaporators for residential air conditioning systems and the oil detrimental effects on evaporator capacity and refrigerant-side pressure drop were investigated. The working fluids used in this study were R410A, as reference refrigerant, and low global warming potential refrigerants R32, R1234yf, and R454B, a new low global warming potential mixture candidate to replace R410A, whereas the lubricant was VG 32 Polyolester oil. The effects of oil mass fractions and degree of superheat were experimentally investigated considering working conditions typically found in air conditioning systems. Finally, the experimental results of the present article provided data that were used to develop and validate a semi-empirical model for microchannel evaporator simulation able to account for the oil presence. The developed model was summarized in the current article and the results were compared with the experimental ones in term of oil retention, capacity, and refrigerant-side pressure drop.
28 November 2018 in Science and Technology for the Built Environment
In refrigeration systems, oil is used to lubricate the moving parts of compressors. Unfortunately, oil is often miscible with refrigerants and it is inevitably discharged to condensers and evaporators. This paper investigated the retention of oil in microchannel type condenser and evaporator of a R134a refrigeration system for light commercial refrigeration applications, vending machines, and water or wine coolers applications. The oil retention was measured and the effect of the oil, both retained and in circulation with the refrigerant inside the microchannel heat exchangers, on the heat transfer capacities and pressure drops were experimentally measured. Saturation temperatures were varied from -18°C (0°F) to 9°C (48°F) for the evaporator and from 35°C (95°F) and up to 54°C (130°F) for the condenser. The oil concentration ranged from 0.5 up to 5 weight percent. When combining both the microchannel condenser and evaporator, the overall oil retention volume resulted from 7% and up to 38% of the oil amount potentially charged inside compressors. Heat transfer capacity of the evaporator was penalized by 5% to 12%. Refrigerant-side pressure drops increased significantly and the system coefficient of performance was projected to decrease by more than 4%.
21 February 2017 in Science and Technology for the Built Environment
This article investigated the feasibility a new load-based method of test for assessing the comprehensive performance figure of merit of roof top units. The measurements, according to the new load-based approach, characterize the relative changes in the unit performance when it operates in the field as if the unit was installed in an actual building. Depending on the mode of operation and on the outdoor air dry-bulb temperature, the roof top unit efficiency was about 41% to 9% lower than the steady state efficiencies determined by using the ASHRAE 116 Standard if the operation mode of the roof top unit was with economizer closed to the fixed minimum outside air position and without any speed control. When both the economizer and speed control technologies were activated, the measured efficiency increased to 205% with respect to the steady state efficiency. The focus of the load-based test was to provide data that could be used to project energy use and change point linear inverse modeling following ASHRAE Guideline (2014) could be applied to the data to compare expected annual energy use for the baseline (i.e., roof top unit with minimum outside air) to the improved modes of operation with fan speed control and outside air economizer control.
(2019). Cutting edge research and new technologies in heat and mass transfer processes of refrigeration and air conditioning systems. Science and Technology for the Built Environment: Vol. 25, Topical Issue: Purdue Conference 2018. Guest Edtiors: Lorenzo Cremaschi and Kyle R. Gluesenkamp, pp. 1269-1270.