26 January 2023 in Building and Environment
MOMohd Hafiz Dzarfan Othman
Mohd Hafiz Dzarfan Othman
+5
1 November 2010 in Cryogenics
FIFerdiansyah N. Iskandar
1 July 2018 in International Journal of Refrigeration
SMSarath Kumar Mulugurthi
28 November 2018 in Science and Technology for the Built Environment
In refrigeration systems, oil is used to lubricate the moving parts of compressors. Unfortunately, oil is often miscible with refrigerants and it is inevitably discharged to condensers and evaporators. This paper investigated the retention of oil in microchannel type condenser and evaporator of a R134a refrigeration system for light commercial refrigeration applications, vending machines, and water or wine coolers applications. The oil retention was measured and the effect of the oil, both retained and in circulation with the refrigerant inside the microchannel heat exchangers, on the heat transfer capacities and pressure drops were experimentally measured. Saturation temperatures were varied from -18°C (0°F) to 9°C (48°F) for the evaporator and from 35°C (95°F) and up to 54°C (130°F) for the condenser. The oil concentration ranged from 0.5 up to 5 weight percent. When combining both the microchannel condenser and evaporator, the overall oil retention volume resulted from 7% and up to 38% of the oil amount potentially charged inside compressors. Heat transfer capacity of the evaporator was penalized by 5% to 12%. Refrigerant-side pressure drops increased significantly and the system coefficient of performance was projected to decrease by more than 4%.
18 October 2016 in Science and Technology for the Built Environment
PDPratik Shashikant Deokar
Oil retention in a microchannel type condenser was measured and its effect on heat transfer rate performance and pressure drop were analyzed for refrigerants R410A and R134a condensation. The heat exchanger was a 2-pass aluminum louvered-fin type consists of multiports rectangular channels with hydraulic diameter of 0.06 inch (1.7 × 10−3 m). The refrigerants and Polyolester oil mixtures were studied at saturation temperature from 85 to 130°F (29 to 54°C) and oil mass fraction (OMF) was varied from 0 to 6 wt.%. Oil retained in the condenser was found to be strongly dependent on the OMF and it was measured up to 11% of its internal volume. The oil retained for high mass fluxes were higher than those for low mass fluxes. The effect of mass flux on the oil retention was small for low OMFs but became more evident for OMFs of 3 wt.% and higher. The oil penalized the heat transfer capacity by as much as 10% when the OMF was 3 wt.%. For medium temperature of 105°F (41°C) the heat transfer capacities were fairly constant. Nevertheless, the high refrigerant-oil mixture viscosity of the liquid phase increased the pressure losses up to 19% compared to that in oil free conditions.
1 January 2019 in AIP Conference Proceedings