Fedan Avrumova

Ms. Fedan Avrumova


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2023 in The Bone & Joint Journal
Verified
Journal Article
Closed access
PDF file
FAFrederik Abel
Frederik Abel
FAFedan Avrumova
Fedan Avrumova
SGSamuel N. Goldman
Samuel N. Goldman
CACeleste Abjornson
Celeste Abjornson
DLDarren R. Lebl
Darren R. Lebl
Aims: The aim of this study was to assess the accuracy of pedicle screw placement, as well as intraoperative factors, radiation exposure, and complication rates in adult patients with degenerative disorders of the thoracic and lumbar spines who have undergone robotic-navigated spinal surgery using a contemporary system.Methods: The authors reviewed the prospectively collected data on 196 adult patients who had pedicle screws implanted with robot-navigated assistance (RNA) using the Mazor X Stealth system between June 2019 and March 2022. Pedicle screws were implanted by one experienced spinal surgeon after completion of a learning period. The accuracy of pedicle screw placement was determined using intraoperative 3D fluoroscopy.Results: A total of 1,123 pedicle screws were implanted: 1,001 screws (89%) were placed robotically, 63 (6%) were converted from robotic placement to a freehand technique, and 59 (5%) were planned to be implanted freehand. Of the robotically placed screws, 942 screws (94%) were determined to be Gertzbein and Robbins grade A with median deviation of 0.8 mm (interquartile range 0.4 to 1.6). Skive events were noted with 20 pedicle screws (1.8%). No adverse clinical sequelae were noted in the 90-day follow-up. The mean fluoroscopic exposure per screw was 4.9 seconds (SD 3.8).Conclusion: RNA is highly accurate and reliable, with a low rate of abandonment once mastered. No adverse clinical sequelae occurred after implanting a large series of pedicle screws using the latest generation of RNA. Understanding of patient-specific anatomical features and the real-time intraoperative identification of risk factors for suboptimal screw placement have the potential to improve accuracy further.Cite this article: Bone Joint J 2023;105-B(5):543–550.

29 June 2021 in HSS Journal®: The Musculoskeletal Journal of Hospital for Special Surgery
Verified
Journal Article
Closed access
PDF file
FAFedan Avrumova
Fedan Avrumova
ASAhilan Sivaganesan
Ahilan Sivaganesan
RARam Kiran Alluri
Ram Kiran Alluri
AVAvani Vaishnav
Avani Vaishnav
SQSheeraz Qureshi
Sheeraz Qureshi
DLDarren R. Lebl
Darren R. Lebl

7 February 2024 in Global Spine Journal
Verified
Journal Article
Open access
FAFranziska C. S. Altorfer
Franziska C. S. Altorfer
MBMarco D. Burkhard
Marco D. Burkhard
MKMichael J. Kelly
Michael J. Kelly
FAFedan Avrumova
Fedan Avrumova
DSDarryl B. Sneag
Darryl B. Sneag
DLDarren R. Lebl
Darren R. Lebl
Study Design: Human Cadaveric Study. Objective: This study aims to explore the feasibility of using preoperative magnetic resonance imaging (MRI), zero-time-echo (ZTE) and spoiled gradient echo (SPGR), as source data for robotic-assisted spine surgery and assess the accuracy of pedicle screws. Methods: Zero-time-echo and SPGR MRI scans were conducted on a human cadaver. These images were manually post-processed, producing a computed tomography (CT)-like contrast. The Mazor X robot was used for lumbar pedicle screw-place navigating of MRI. The cadaver underwent a postoperative CT scan to determine the actual position of the navigated screws. Results: Ten lumbar pedicle screws were robotically navigated of MRI (4 ZTE; 6 SPGR). All MR-navigated screws were graded A on the Gertzbein-Robbins scale. Comparing preoperative robotic planning to postoperative CT scan trajectories: The screws showed a median deviation of overall 0.25 mm (0.0; 1.3), in the axial plane 0.27 mm (0.0; 1.3), and in the sagittal plane 0.24 mm (0.0; 0.7). Conclusion: This study demonstrates the first successful registration of MRI sequences, ZTE and SPGR, in robotic spine surgery here used for intraoperative navigation of lumbar pedicle screws achieving sufficient accuracy, showcasing potential progress toward radiation-free spine surgery.

2 November 2024 in The Spine Journal
Verified
Journal Article
Closed access
FAFranziska C.S. Altorfer
Franziska C.S. Altorfer
MKMichael Kelly
Michael Kelly
FAFedan Avrumova
Fedan Avrumova
Marco D. BurkhardMarco D. Burkhard
Marco D. Burkhard
DSDarryl B. Sneag
Darryl B. Sneag
DLDarren R. Lebl
Darren R. Lebl

4 March 2025 in The Spine Journal
Verified
Journal Article
Closed access
FAFranziska C.S. Altorfer
Franziska C.S. Altorfer
MKMichael Kelly
Michael Kelly
FAFedan Avrumova
Fedan Avrumova
VRVarun Rohatgi
Varun Rohatgi
JZJiaqi Zhu
Jiaqi Zhu
DLDarren R. Lebl
Darren R. Lebl

8 February 2024 in Journal of Robotic Surgery
Verified
Journal Article
Closed access
PDF file
GGGeorge Gorgy
George Gorgy
FAFedan Avrumova
Fedan Avrumova
PPPhilip K. Paschal
Philip K. Paschal
GPGregory K. Paschal
Gregory K. Paschal
JCJohn A. Carrino
John A. Carrino
DLDarren R. Lebl
Darren R. Lebl