Marco D. Burkhard

Dr. Marco D. Burkhard

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 December 2018 in European Spine Journal
Verified
Journal Article
Closed access
PDF file
Marco D. BurkhardMarco D. Burkhard
Marco D. Burkhard
Philipp FürnstahlPhilipp Fürnstahl
Philipp Fürnstahl
MFMazda Farshad
Mazda Farshad

10 January 2017 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
SMSandra Mathews
Sandra Mathews
Marco D. BurkhardMarco D. Burkhard
Marco D. Burkhard
NSNabil Serrano
Nabil Serrano
KLKarl Link
Karl Link
MHMartin Haeusler
Martin Haeusler
EEElisabeth Eppler
Elisabeth Eppler
Placement of the glenoid baseplate is of paramount importance for the outcome of anatomical and reverse total shoulder arthroplasty. However, the database around glenoid size is poor, particularly regarding small scapulae, for example, in women and smaller individuals, and is derived from different methodological approaches. In this multimodality cadaver study, we systematically examined the glenoid using morphological and 3D-CT measurements. Measurements of the glenoid and drill hole tunnel length for superior baseplate screw placement were recorded to define size of the glenoid and the distance to the scapular notch on cadaveric specimens. Glenoid angles were determined on both, 3D-CT-scans of the thoraxes using the Friedman method and on subsequently isolated scapulae from 18 male and female donors (average 84 years, range 60–98 years). Mean glenoid height was 36.6 mm ± 3.6, and width 27.8 mm ± 3.1 with a significant sex dimorphism (p ≤ 0.001): in males, glenoid height 39.5 mm ± 3.5, and width 30.3 mm ± 3.3, and in females, glenoid height 34.8 mm ± 2.2, and width 26.2 mm ± 1.6. The average distance from the superior screw entry to its exit in the scapular notch measured by calliper was 27.2 mm ± 6.0 with a sex difference: in males, 29.4 mm ± 5.7, and in females, 25.8 mm ± 5.9 mm with a minimum recorded distance of 15 mm. Measured by CT, the mean inclination angle for male and female donors combined was 13.0° ± 7.0, and the ante-/retroversion angle −1.0° ± 4.0°. This study is one of the first to combine dissection, including drill holes, with anatomical measurements and radiological data. In some women and smaller individuals, smaller baseplates should be selected. The published safe zone of 20 mm is generally feasible for superior screw placement, however, in small patients this distance may be substantially shorter than expected and start as of 13 and 15 mm, respectively. No correlation between glenoid height or width with the length of our drilling canal towards the scapular notch was found. Preoperative CT-based treatment planning to determine version and inclination angles is recommended.

24 April 2023 in European Spine Journal
Verified
Journal Article
Open access
PDF file
Marco D. BurkhardMarco D. Burkhard
Marco D. Burkhard
ACAnna-Katharina Calek
Anna-Katharina Calek
MFMarie-Rosa Fasser
Marie-Rosa Fasser
FCFrédéric Cornaz
Frédéric Cornaz
JWJonas Widmer
Jonas Widmer
MFMazda Farshad
Mazda Farshad
Purpose: The aim of this study was to elucidate segmental range of motion (ROM) before and after common decompression and fusion procedures on the lumbar spine. Methods: ROM of fourteen fresh-frozen human cadaver lumbar segments (L1/2: 4, L3/4: 5, L5/S1: 5) was evaluated in six loading directions: flexion/extension (FE), lateral bending (LB), lateral shear (LS), anterior shear (AS), axial rotation (AR), and axial compression/distraction (AC). ROM was tested with and without posterior instrumentation under the following conditions: 1) native 2) after unilateral laminotomy, 3) after midline decompression, and 4) after nucleotomy. Results: Median native ROM was FE 6.8°, LB 5.6°, and AR 1.7°, AS 1.8 mm, LS 1.4 mm, AC 0.3 mm. Unilateral laminotomy significantly increased ROM by 6% (FE), 3% (LB), 12% (AR), 11% (AS), and 8% (LS). Midline decompression significantly increased these numbers to 15%, 5%, 21%, 20%, and 19%, respectively. Nucleotomy further increased ROM in all directions, most substantially in AC of 153%. Pedicle screw fixation led to ROM decreases of 82% in FE, 72% in LB, 42% in AR, 31% in AS, and 17% in LS. In instrumented segments, decompression only irrelevantly affected ROM. Conclusions: The amount of posterior decompression significantly impacts ROM of the lumbar spine. The here performed biomechanical study allows creation of a simplified rule of thumb: Increases in segmental ROM of approximately 10%, 20%, and 50% can be expected after unilateral laminotomy, midline decompression, and nucleotomy, respectively. Instrumentation decreases ROM by approximately 80% in bending moments and accompanied decompression procedures only minorly destabilize the instrumentation construct.

1 February 2020 in World Neurosurgery
Verified
Journal Article
Closed access
CRColleen Rentenberger
Colleen Rentenberger
IOIchiro Okano
Ichiro Okano
SSStephan N. Salzmann
Stephan N. Salzmann
FWFabian Winter
Fabian Winter
NPNicolas Plais
Nicolas Plais
AHAlexander P. Hughes
Alexander P. Hughes

1 March 2021 in The Spine Journal
Verified
Journal Article
Open access
Marco D. BurkhardMarco D. Burkhard
Marco D. Burkhard
RLRuben Loretz
Ruben Loretz
IUIlker Uçkay
Ilker Uçkay
DBDavid E. Bauer
David E. Bauer
MBMichael Betz
Michael Betz
MFMazda Farshad
Mazda Farshad
Pseudarthrosis after attempted spinal fusion is yet not sufficiently understood and presents a surgical challenge. Occult infections are sometimes observed in patients with pseudarthrosis and no inflammatory signs of infection. The prevalence of such occult infection and its association with patient demographics and inflammatory markers are largely unknown. To determine the prevalence of unexpected low-grade infection in spinal pseudarthrosis revision surgery, and to evaluate whether such infection is associated with patient demographics and inflammatory markers. Retrospective observational study. One-hundred-and-twenty-eight patients who underwent thoracolumbar revision surgery due to presumed aseptic pseudarthrosis after spinal instrumentation. Culture-positive infections or noninfectious pseudarthrosis. Samples were routinely taken for microbiological examination from all adults (n=152) who underwent revision surgery for presumed aseptic thoracolumbar pseudarthrosis between 2014 and 2019. A full intraoperative microbiological workup (at least three intraoperative tissue samples) was done for 128 (84%) patients, and these patients were included in further analyses. Patient characteristics, medical history, inflammatory markers, and perioperative data were compared between those with and without microbiologically-confirmed infection based on samples obtained during pseudarthrosis revision. The microbiological workup confirmed infection in 13 of 128 cases (10.2%). The predominant pathogen was Cutibacterium acnes (46.2%), followed by coagulase-negative staphylococci (38.5%). The presence of infection was associated with the body mass index (30.9±4.7 kg/m2 [infected] vs. 28.2±5.6 kg/m2 [controls], p=.049), surgery in the thoracolumbar region (46% vs. 18%, p=.019), and a slightly higher serum C-reactive protein level on admission (9.4±8.0 mg/L vs. 5.7±7.1 mg/L, p=.031). Occult infection was not associated with age, sex, prior lumbar surgeries, number of fused lumbar levels, American Society of Anesthesiologist score, Charlson Comorbidity Index, presence of diabetes mellitus, and smoking status. Occult infections were found in 10% of patients undergoing pseudarthrosis revision after spinal fusion, even without preoperative clinical suspicion. Occult infection was associated with higher body mass index, fusions including the thoracolumbar junction, and slightly higher C-reactive protein levels. Intraoperative microbiological samples should be routinely obtained to exclude or identify occult infection in all revision surgeries for symptomatic pseudarthrosis of the spine, as this information can be used to guide postoperative antibiotic treatment.

6 November 2024 in Global Spine Journal
Verified
Journal Article
Open access
Marco D. BurkhardMarco D. Burkhard
Marco D. Burkhard
ECErika Chiapparelli
Erika Chiapparelli
JHJan Hambrecht
Jan Hambrecht
PKPaul Köhli
Paul Köhli
AGAli E. Guven
Ali E. Guven
AHAlexander P. Hughes
Alexander P. Hughes
Study Design: Retrospective cohort study. Objectives: To identify imaging predictors on pre- and perioperative imaging that are associated with a future revision surgery for adjacent segment disease (ASD) following lumbar fusion. Methods: Patients undergoing open posterior lumbar fusion between 2014-2022 were followed-up for >2-year. The initial MRI was evaluated for disc degeneration by Pfirrmann (grade 1-5); Modic changes (0-3); as well as fatty infiltration and functional cross-sectional area (fCSA) of the multifidus, erector spinae, and psoas. Spinopelvic alignment was measured pre- and postoperatively. Results: Of 216 patients, 14.8% (n = 32) required revision surgery for ASD in the further course. There were no significant differences in Modic changes or Pfirrmann grades between the ASD group and controls. Fatty infiltration was significantly higher in the ASD group for both the erector spinae (40.5% vs 36.9%, P = 0.043) and multifidus muscles (61.0% vs 53.9%, P = 0.003). Additionally, the multifidus fCSA was smaller in patients who developed ASD (5.7 cm 2 vs 6.7 cm 2 ). Pre- and postoperative spinopelvic parameters were not significantly different between groups, and no other MRI measurements showed a significant difference. In a multivariable logistic regression model adjusting for age and sex, multifidus fatty infiltration emerged as the only significant predictor of ASD revision surgery ( P = 0.004). Patients with more than 58% multifidus fatty infiltration had over double the risk of developing ASD (OR 2.7, 95% CI: 1.1-6.5, P = 0.032). Conclusions: Multifidus fatty infiltration is the key imaging predictor for the development of ASD requiring surgical revision. Disc degeneration and spinopelvic alignment appear to have less impact.