Tilektes Zh. Shugayeva

Dr. Tilektes Zh. Shugayeva

Heriot-Watt University, Aktobe, Kazakhstan
orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

25 June 2026 in Frontiers in Education
Verified
Journal Article
Open access
Tilektes Zh. ShugayevaTilektes Zh. Shugayeva
Tilektes Zh. Shugayeva
ISIgor Spivak-Lavrov
Igor Spivak-Lavrov
ATAigerim Taspenova
Aigerim Taspenova
ZKZhanar Kambarova
Zhanar Kambarova
ATAinura Tussupbekova
Ainura Tussupbekova
This study investigates how inquiry-oriented mathematical modeling can support the development of upper secondary students' research skills in astronomy, focusing on the phenomenon of day and night duration. The study presents an instructional approach using a VBA-based Excel tool to calculate day length, solar culmination height, and relative solar energy. The effectiveness of the intervention was evaluated through the quasi-experimental study based on motivational-orientational, operational-activity, and reflective-evaluative criteria. The results demonstrate statistically significant improvements in students' inquiry-related skills, particularly in data interpretation, hypothesis formulation, and reflective evaluation ( p < 0.05; Cohen's d = 1.35). The findings show that 86.4% of students achieved high or medium levels of operational skills, while 90.9% demonstrated well-developed reflective-evaluative competencies. The study concludes that the VBA-based modeling environment effectively enables students to transition from passive observation to active inquiry, bridging the gap between theoretical astronomical concepts and independent data interpretation. This study is framed within the STEM education paradigm, emphasizing the integration of science, technology, engineering, and mathematics in fostering students' inquiry skills.

1 December 2023 in Recent Contributions to Physics
Verified
Journal Article
Open access
PDF file
ISIgor Spivak-Lavrov
Igor Spivak-Lavrov
TST.Zh. Shugaeva
T.Zh. Shugaeva
ASA.B. Seiten
A.B. Seiten
The development of methods for calculating the physical and instrument characteristics of mass spectrometers based on correct physical and mathematical theories that allow us to design and calculate devices with improved analytical capabilities is an urgent task of corpuscular optics and scientific instrumentation. Currently, quadrupole electrostatic systems are widely used. These are primarily quadrupole lenses, quadrupole aberration correctors, quadrupole traps and quadrupole mass spectrometers. The quadrupole mass analyzer refers to the so-called antiresonance mass spectrometers, in which a part of the ions, when a beam of ions moves through an electric field having both a constant and a time-varying component, passes a field with a limited amplitude of vibrations, while the amplitude of vibrations of the other part of the ions increases indefinitely with time, and drop out of the bundle. Since the nature of the motion of charged particles depends on the mass-to-charge ratio, such an electric field can work as a mass filter, that is, pass through itself only ions having a certain value of the mass-to-charge ratio. Quadrupole systems with complex electrode geometries are usually used to create quadrupole fields, which makes their practical implementation difficult. Therefore, the development and research of quadrupole systems with a fairly simple geometry of electrodes, the fields of which can be described analytically, is quite relevant. Using a simple analytical formula for the potential and its derivatives, which accurately describes the electrostatic potential of a quadrupole field, it is possible to accurately calculate the stability regions of quadrupole ion traps when additional radio frequency fields are applied. Разработка методов расчета физических и приборных характеристик масс-спектрометров, основанных на корректных физических и математических теориях, которые позволяют проектировать и рассчитывать приборы с улучшенными аналитическими возможностями, является актуальной задачей корпускулярной оптики и научного приборостроения. В настоящее время квадрупольные электростатические системы получили широкое распространение. Это прежде всего, квадрупольные линзы, квадрупольные корректоры аберраций, квадрупольные ловушки и квадрупольные масс-спектрометры. Квадрупольный масс-анализатор относится к так называемым антирезонансным масс-спектрометрам, в которых часть ионов при движении пучка ионов через электрическое поле, имеющее, как постоянную, так и изменяющуюся во времени составляющую, проходит поле с ограниченной амплитудой колебаний, в то время как амплитуда колебаний другой части ионов неограниченно возрастает со временем, и они выбывают из пучка. Так как характер движения заряженных частиц зависит от отношения массы к заряду, то такое электрическое поле может работать как масс-фильтр, то есть пропускать через себя только ионы, имеющие определенное значение отношения массы к заряду. Для создания квадрупольных полей обычно используются квадрупольные системы со сложной геометрией электродов, что затрудняет их практическую реализацию. Поэтому достаточно актуальна разработка и исследование квадрупольных систем с достаточно простой геометрией электродов, поля которых могут быть описаны аналитически. Используя для потенциала и его производных простую аналитическую формулу, которая точно описывает электростатический потенциал квадрупольного поля, можно точно рассчитать области стабильности квадрупольных ионных ловушек при наложении дополнительных радиочастотных полей. Жақсартылған аналитикалық мүмкіндіктері бар құрылғыларды жобалауға және есептеуге мүмкіндік беретін дұрыс физикалық және математикалық теорияларға негізделген масс-спектрометрлердің физикалық және аспаптық сипаттамаларын есептеу әдістерін әзірлеу корпускулалық оптика мен ғылыми аспап жасаудың өзекті міндеті болып табылады. Қазіргі уақытта квадрупольді электростатикалық жүйелер кең таралған. Бұл, ең алдымен, квадрупольді линзалар, квадрупольді аберрация түзеткіштері, квадрупольді...

23 December 2025 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
PDF file
Tilektes Zh. ShugayevaTilektes Zh. Shugayeva
Tilektes Zh. Shugayeva
ISIgor Spivak-Lavrov
Igor Spivak-Lavrov
OBOrda Baisanov
Orda Baisanov
AAAmangul Amantayeva
Amangul Amantayeva
This study explores a multi-reflection time-of-flight mass spectrometer (TOFMS) based on transaxial electrostatic mirrors providing spatial and energy time-of-flight focusing of the ion beam. Analysis of existing solutions reveals that spatial-energy time-of-flight focusing in compact TOFMSs is achieved using additional focusing elements, which complicates the design, limits resolution, and reduces sensitivity. This paper demonstrates that three-electrode transaxial mirrors enable simultaneous spatial and energy time-of-flight focusing of ions without the use of additional focusing elements. Monte Carlo simulation of the beam dynamics has made it possible to determine the trajectories and flight times of ions under various initial conditions. It was found that two closely spaced vertical focusing modes provide time-of-flight focusing of ions with a relative energy spread of . A mass resolution of 10,000 at half-maximum confirms the high efficiency of the proposed structure. The spatial distributions of the ion beam demonstrate stable focusing in the detector plane when modeling particles larger than 1000. The results are attributed to the features of transaxial geometry, which enables three-dimensional spatial and energy time-of-flight focusing. The practical significance of this work is the applicability of such multi-reflector mass analyzers in laboratory and space research where a combination of high resolution and instrument compactness is required

25 June 2026 in Bulletin of the Karaganda University "Physics Series"
Verified
Journal Article
Closed access
MTM.K. Tungushbekova
M.K. Tungushbekova
ZKZhanar Kambarova
Zhanar Kambarova
ASA.O. Saulebekov
A.O. Saulebekov
ATA.A. Trubitsyn
A.A. Trubitsyn
TST.ZH. Shugayeva
T.ZH. Shugayeva
A design of an electrostatic mirror energy analyzer for the analysis of charged particle beams based on a new ly synthesized field is proposed. The electrostatic field of the analyzer is formed as a superposition of an axi ally symmetric multipole field and a spherical field. The structure of the electrostatic field formed by the su perposition of axially symmetric octupole and spherical fields has been investigated. It is shown that varying the parameters determining the contribution of multipole components allows controlling the aberration prop erties of the electron-optical system. Conditions for compensating for second- and third-order aberrations have been obtained by selecting appropriate values for the weight coefficients of the hexapole and octupole components, which allows for a significant improvement in the focusing properties of the field. Numerical modeling of the electron-optical system and calculation of charged particle trajectories were carried out using the “FOCUS” simulation program. Two regimes of angular focusing were found. The first mode corresponds to second-order angular focusing at a particle input angle of 68°, while the second regime implements third order focusing at an input angle of 90°. The instrumental functions of the device were constructed, and the relative energy resolutions and luminosities of the analyzer were evaluated. The proposed electron-optical schemes can be used in the development of high-resolution spectrometers for analyzing charged particle beams in space research, as well as spectrographs for the energy-angle analysis of solid surfaces.

9 November 2026 in Physica Scripta
Verified
Journal Article
Open access
TST Zh Shugayeva
T Zh Shugayeva
ISIgor Spivak-Lavrov
Igor Spivak-Lavrov
ATA A Trubitsyn
A A Trubitsyn
ABA O Baisanov
A O Baisanov
ZKZhanar Kambarova
Zhanar Kambarova
This paper presents numerical modeling of a pulsed ring ion source and the ion-optical system of a time-of-flight mass spectrometer (TOF-MS) with an axially—symmetric electrostatic mirror. The relevance of this study is determined by the fact that, in the considered electrostatic mirror configuration, ions must be introduced as a ring-shaped packet, whereas conventional ion sources generally form a beam in the shape of a small spot near the symmetry axis of the system. In this regard, a pulsed ring ion source configuration is proposed and numerically investigated, enabling the formation, extraction, and preliminary acceleration of a ring-shaped ion packet. It is shown that modifying the source geometry, reducing the accelerating gap, and introducing a correcting cylindrical electrode make it possible to reduce the effect of potential sagging, and ensure ion transmission to the entrance of the mass analyzer under conditions of strong preliminary acceleration The high efficiency of axially-symmetric electrostatic mirrors is due to their ability to provide simultaneous spatial and time-of-flight focusing of ion packets. The electrode system of such a mirror is formed by cylindrical electrodes sharing a common axis, which is consistent with the ring geometry of ion injection and enables the implementation of the two spatial and time-of-flight focusing modes, namely ‘ring-to-axis’ and ‘axis-to-ring’. The potential distribution in such a system is represented in a relatively simple analytical form. To determine the trajectories and flight times of charged particles in the electrostatic field of the deflector, dimensionless Newtonian equations are used; these equations are integrated by the Adams method with automatic selection of the integration step. The starting values required for the integration were determined using Krylov’s method of successive approximations, and the relative integration accuracy was set to 10 −9 . The calculation of spatial focusing and the arrival time of particles at the detector plane was performed using the Monte Carlo method, with normally distributed events within a specified range of initial parameters. The simulations demonstrated that the resolving power of the TOF-MS can be increased up to 5000 at 50% of the peak height, which makes the proposed system promising for compact high-sensitivity spaceborne mass spectrometers. The proposed TOF-MS configuration is intended for the analysis of low-energy ions in gas-phase applications, with particular emphasis on compact spaceborne instruments for planetary atmospheric and cometary composition measurements.