Emilia Farcas

Dr. Emilia Farcas

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 October 2023
Verified
Conference Paper
Open access
CCChen Chen
Chen Chen
ELElla T Lifset
Ella T Lifset
YHYichen Han
Yichen Han
ARArkajyoti Roy
Arkajyoti Roy
MHMichael Hogarth
Michael Hogarth
NWNadir Weibel
Nadir Weibel
While voice user interfaces offer increased accessibility due to hands-free and eyes-free interactions, older adults often have challenges such as constructing structured requests and perceiving how such devices operate. Voice-first user interfaces have the potential to address these challenges by enabling multimodal interactions. Standalone voice + touchscreen Voice Assistants (VAs), such as Echo Show, are specific types of devices that adopt such interfaces and are gaining popularity. However, the affordances of the additional touchscreen for older adults are unknown. Through a 40-day real-world deployment with older adults living independently, we present a within-subjects study (N = 16; age M = 82.5, SD = 7.77, min. = 70, max. = 97) to understand how a built-in touchscreen might benefit older adults during device setup, conducting self-report diary survey, and general uses. We found that while participants appreciated the visual outputs, they still preferred to respond via speech instead of touch. We identified six design implications that can inform future innovations of senior-friendly VAs for managing healthcare and improving quality of life.

10 July 2023
Verified
Conference Paper
Open access
CCChen Chen
Chen Chen
ELElla T. Lifset
Ella T. Lifset
YHYichen Han
Yichen Han
ARArkajyoti Roy
Arkajyoti Roy
MHMichael Hogarth
Michael Hogarth
NWNadir Weibel
Nadir Weibel
While standalone Voice Assistants (VAs) are promising to support older adults’ daily routine and wellbeing management, onboarding and setting up these devices can be challenging. Although some older adults choose to seek assistance from technicians and adult children, easy set up processes that facilitate independent use are still critical, especially for those who do not have access to external resources. We aim to understand the older adults’ experience while setting up commercially available voice-only and voice-first screen-based VAs. Rooted in participants observations and semi-structured interviews, we designed a within-subject study with 10 older adults using Amazon Echo Dot and Echo Show. We identified the values of the built-in touchscreen and the instruction documents, as well as the impact of form factors, and outline important directions to support older adult independence with VAs.

2 August 2024 in JMIR Rehabilitation and Assistive Technologies
Verified
Journal Article
Open access
ALAudrey Lee
Audrey Lee
EWElijah Wyckoff
Elijah Wyckoff
EFEmilia Farcas
Emilia Farcas
JGJob G Godino
Job G Godino
KPkevin patrick
kevin patrick
SGSara Gombatto
Sara Gombatto
Background: Low back pain (LBP) is a significant public health problem that can result in physical disability and financial burden for the individual and society. Physical therapy is effective for managing LBP and includes evaluation of posture and movement, interventions directed at modifying posture and movement, and prescription of exercises. However, physical therapists have limited tools for objective evaluation of low back posture and movement and monitoring of exercises, and this evaluation is limited to the time frame of a clinical encounter. There is a need for a valid tool that can be used to evaluate low back posture and movement and monitor exercises outside the clinic. To address this need, a fabric-based, wearable sensor, Motion Tape (MT), was developed and adapted for a low back use case. MT is a low-profile, disposable, self-adhesive, skin-strain sensor developed by spray coating piezoresistive graphene nanocomposites directly onto commercial kinesiology tape. Objective: The objectives of this study were to (1) validate MT for measuring low back posture and movement and (2) assess the acceptability of MT for users. Methods: A total of 10 participants without LBP were tested. A 3D optical motion capture system was used as a reference standard to measure low back kinematics. Retroreflective markers and a matrix of MTs were placed on the low back to measure kinematics (motion capture) and strain (MT) simultaneously during low back movements in the sagittal, frontal, and axial planes. Cross-correlation coefficients were calculated to evaluate the concurrent validity of MT strain in reference motion capture kinematics during each movement. The acceptability of MT was assessed using semistructured interviews conducted with each participant after laboratory testing. Interview data were analyzed using rapid qualitative analysis to identify themes and subthemes of user acceptability. Results: Visual inspection of concurrent MT strain and kinematics of the low back indicated that MT can distinguish between different movement directions. Cross-correlation coefficients between MT strain and motion capture kinematics ranged from –0.915 to 0.983, and the strength of the correlations varied across MT placements and low back movement directions. Regarding user acceptability, participants expressed enthusiasm toward MT and believed that it would be helpful for remote interventions for LBP but provided suggestions for improvement. Conclusions: MT was able to distinguish between different low back movements, and most MTs demonstrated moderate to high correlation with motion capture kinematics. This preliminary laboratory validation of MT provides a basis for future device improvements, which will also involve testing in a free-living environment. Overall, users found MT acceptable for use in physical therapy for managing LBP.

29 February 2024 in JMIR Human Factors
Verified
Journal Article
Open access
ALAudrey Lee
Audrey Lee
PDPatricia Dionicio
Patricia Dionicio
EFEmilia Farcas
Emilia Farcas
JGJob G Godino
Job G Godino
KPkevin patrick
kevin patrick
SGSara Gombatto
Sara Gombatto
Background: Low back pain (LBP) is a costly global health condition that affects individuals of all ages and genders. Physical therapy (PT) is a commonly used and effective intervention for the management of LBP and incorporates movement assessment and therapeutic exercise. A newly developed wearable, fabric-based sensor system, Motion Tape, uses novel sensing and data modeling to measure lumbar spine movements unobtrusively and thus offers potential benefits when used in conjunction with PT. However, physical therapists’ acceptance of Motion Tape remains unexplored. Objective: The primary aim of this research study was to evaluate physical therapists’ acceptance of Motion Tape to be used for the management of LBP. The secondary aim was to explore physical therapists’ recommendations for future device development. Methods: Licensed physical therapists from the American Physical Therapy Association Academy of Leadership Technology Special Interest Group participated in this study. Overall, 2 focus groups (FGs; N=8) were conducted, in which participants were presented with Motion Tape samples and examples of app data output on a poster. Informed by the Technology Acceptance Model, we conducted semistructured FGs and explored the wearability, usefulness, and ease of use of and suggestions for improvements in Motion Tape for PT management of LBP. FG data were transcribed and analyzed using rapid qualitative analysis. Results: Regarding wearability, participants perceived that Motion Tape would be able to adhere for several days, with some variability owing to external factors. Feedback was positive for the low-profile and universal fit, but discomfort owing to wires and potential friction with clothing was of concern. Other concerns included difficulty with self-application and potential skin sensitivity. Regarding usefulness, participants expressed that Motion Tape would enhance the efficiency and specificity of assessments and treatment. Regarding ease of use, participants stated that the app would be easy, but data management and challenges with interpretation were of concern. Physical therapists provided several recommendations for future design improvements including having a wireless system or removable wires, customizable sizes for the tape, and output including range of motion data and summary graphs and adding app features that consider patient input and context. Conclusions: Several themes related to Motion Tape’s wearability, usefulness, and ease of use were identified. Overall, physical therapists expressed acceptance of Motion Tape’s potential for assessing and monitoring low back posture and movement, both within and outside clinical settings. Participants expressed that Motion Tape would be a valuable tool for the personalized treatment of LBP but highlighted several future improvements needed for Motion Tape to be used in practice.

17 June 2025 in Sensors
Verified
Journal Article
Open access
PDF file
EWElijah Wyckoff
Elijah Wyckoff
SGSara Gombatto
Sara Gombatto
YVYasmin Velazquez
Yasmin Velazquez
JGJob G Godino
Job G Godino
KPkevin patrick
kevin patrick
Kenneth J LohKenneth J Loh
Kenneth J Loh
Monitoring posture and movement accurately and efficiently is essential for both physical therapy and athletic training evaluation and interventions. Motion Tape (MT), a self-adhesive wearable skin-strain sensor made of piezoresistive graphene nanosheets (GNS), has demonstrated promise in capturing low back posture and movements. However, to address some of its limitations, this work explores alternative materials by replacing GNS with multi-walled carbon nanotubes (MWCNT). This study aimed to characterize the electromechanical properties of MWCNT-based MT. Cyclic load tests for different peak tensile strains ranging from 1% to 10% were performed on MWCNT-MT made with an aqueous ink of 2% MWCNT. Additional tests to examine load rate sensitivity and fatigue were also conducted. After characterizing the properties of MWCNT-MT, a human subject study with 10 participants was designed to test its ability to capture different postures and movements. Sets of six sensors were made from each material (GNS and MWCNT) and applied in pairs at three levels along each side of the lumbar spine. To record movement of the lower back, all participants performed forward flexion, left and right bending, and left and right rotation movements. The results showed that MWCNT-MT exceeded GNS-MT with respect to consistency of signal stability even when strain limits were surpassed. In addition, both types of MT could assess lower back movements.

1 August 2007
Verified
Conference Paper
Closed access
BDBarry Demchak
Barry Demchak
CFClaudiu Farcas
Claudiu Farcas
EFEmilia Farcas
Emilia Farcas
IKIngolf H. Kruger
Ingolf H. Kruger
Large systems-of-systems often service large numbers of stakeholders - more stakeholders often means more concerns, many of which are crosscutting. The rich services architecture is a type of service-oriented architecture (SOA) that allows hierarchical decomposition of a system architecture into separate concerns, thereby capturing different system aspects and their interactions, and accounting for crosscutting concerns concisely and sensibly. By leveraging emerging enterprise service bus technology, rich services enable a simple and direct deployment mapping to a system-of-systems network. This paper describes a development process that leverages rich services and is compatible with agile development methodologies. It encompasses use cases, requirements decomposition, role identification, and service definition to produce a rich services logical architecture that can then be mapped to a virtual network topology, and finally a physical network topology. The process decouples development stages to improve flexibility and productivity of complex projects, promising reduced cost and risk.